n_TOF Collaboration(Mendoza, E. et al), Giubrone, G., & Tain, J. L. (2011). Improved Neutron Capture Cross Section Measurements with the n_TOF Total Absorption Calorimeter. J. Korean Phys. Soc., 59(2), 1813–1816.
Abstract: The n_TOF collaboration operates a Total Absorption Calorimeter (TAC) [1] for measuring neutron capture cross-sections of low-mass and/or radioactive samples. The results obtained with the TAC have led to a substantial improvement of the capture cross sections of (237)Np and (240)Pu [2]. The experience acquired during the first measurements has allowed us to optimize the performance of the TAC and to improve the capture signal to background ratio, thus opening the way to more complex and demanding measurements on rare radioactive materials. The new design has been reached by a series of detailed Monte Carlo simulations of complete experiments and dedicated test measurements. The new capture setup will be presented and the main achievements highlighted.
|
|
|
Hornillos, M. B. G., Gorlychev, V., Caballero, R., Cortes, G., Poch, A., Pretel, C., et al. (2011). Monte Carlo Simulations for the Study of a Moderated Neutron Detector. J. Korean Phys. Soc., 59(2), 1573–1576.
Abstract: This work presents the Monte Carlo simulations performed with the MCNPX and GEANT4 codes for the design of a BEta deLayEd Neutron detector, BELEN-20. This detector will be used for the study of beta delayed neutron emission and consists of a block of polyethylene with dimensions 90 x 90 x 80 cm(3) and 20 cylindrical (3)He gas counters. The results of these simulations have been validated experimentally with a (252)Cf source in the laboratory at UPC, Barcelona. Also the first experiment with this detector has been carried out in November 2009 in JYFL, Finland. In this experiment the neutron emission probability after beta decay of the fission products (88)Br, (94,95)Rb, and (138)I has been measured; this data is still under analysis. Simulations with MCNPX and GEANT4 have been performed in order to obtain the efficiency of the BELEN-20 detector for each of the above nuclei using the neutron energy distribution corresponding to each nucleus.
|
|
|
Plaza, J., Bécares, V., Cano-Ott, D., Gómez, C., Martínez, T., Mendoza, E., et al. (2023). CLYC as a neutron detector in low background conditions. Eur. Phys. J. C, 83(11), 1049–10pp.
Abstract: We report on the thermal neutron flux measurements carried out at the Laboratorio Subterraneo de Canfranc (LSC) with two commercial 2 '' x 2 '' CLYC detectors. The measurements were performed as part of an experimental campaign at LSC with He-3 detectors, for establishing the sensitivity limits and use of CLYCs in low background conditions. Acareful characterization of the intrinsic alpha and gamma-ray background in the detectors was required and done with dedicated measurements. It was found that the alpha activities in the two CLYC crystals differ by a factor of three, and the use of Monte Carlo simulations and a Bayesian unfolding method allowed us to determine the specific alpha activities from the U-238 and Th-232 decay chains. The simulations and unfolding also revealed that the gamma-ray background registered in the detectors is dominated by the intrinsic activity of the components of the detector such as the aluminum housing and photo-multiplier and that the activity within the crystal is low in comparison. The data from the neutron flux measurements with the two detectors were analyzed with different methodologies: one based on an innovative alpha/neutron pulse shape discrimination method and one based on the subtraction of the intrinsic alpha background that masks the neutron signals in the region of interest. The neutron sensitivity of the CLYCs was calculated by Monte Carlo simulations with MCNP6 and GEANT4. The resulting thermal neutron fluxes are in good agreement with complementary flux measurement performed with He-3 detectors, but close to the detection limit imposed by the intrinsic a activity.
|
|
|
Guerrero, C., Cano-Ott, D., Mendoza, E., Tain, J. L., Algora, A., Berthoumieux, E., et al. (2012). Monte Carlo simulation of the n_TOF Total Absorption Calorimeter. Nucl. Instrum. Methods Phys. Res. A, 671, 108–117.
Abstract: The n_TOF Total Absorption Calorimeter (TAC) is a 4 pi BaF2 segmented detector used at CERN for measuring neutron capture cross-sections of importance for the design of advanced nuclear reactors. This work presents the simulation code that has been developed in GEANT4 for the accurate determination of the detection efficiency of the TAC for neutron capture events. The code allows to calculate the efficiency of the TAC for every neutron capture state, as a function of energy, crystal multiplicity, and counting rate. The code includes all instrumental effects such as the single crystal detection threshold and energy resolution, finite size of the coincidence time window, and signal pile-up. The results from the simulation have been validated with experimental data for a large set of electromagnetic de-excitation patterns: beta-decay of well known calibration sources, neutron capture reactions in light nuclei with well known level schemes like Ti-nat, reference samples used in (n,gamma) measurements like Au-197 and experimental data from an actinide sample like Pu-240. The systematic uncertainty in the determination of the detection efficiency has been estimated for all the cases. As a representative example, the accuracy reached for the case of Au-197(n,gamma) ranges between 0.5% and 2%, depending on the experimental and analysis conditions. Such a value matches the high accuracy required for the nuclear cross-section data needed in advanced reactor design.
|
|
|
Garcia, A. R., Mendoza, E., Cano-Ott, D., Nolte, R., Martinez, T., Algora, A., et al. (2017). New physics model in GEANT4 for the simulation of neutron interactions with organic scintillation detectors. Nucl. Instrum. Methods Phys. Res. A, 868, 73–81.
Abstract: The accurate determination of the response function of organic scintillation neutron detectors complements their experimental characterization. Monte Carlo simulations with GEANT4 can reduce the effort and cost implied, especially for complex detection systems for which the characterization is more challenging. Previous studies have reported on the inaccuracy of GEANT4 in the calculation of the neutron response of organic scintillation detectors above 6 MeV, due to an incomplete description of the neutron-induced alpha production reactions on carbon. We have improved GEANT4 in this direction by incorporating models and data from NRESP, an excellent Monte Carlo simulation tool developed at the Physikalisch-Technische Bundesanstalt (PTB), Germany, for the specific purpose of calculating the neutron response function of organic scintillation detectors. The results have been verified against simulations with NRESP and validated against Time-Of-Flight measurements with an NE213 detector at PTB. This work has potential applications beyond organic scintillation detectors, to other types of detectors where reactions induced by fast neutrons on carbon require an accurate description.
|
|