Martins, A., da Mota, A. F., Stanford, C., Contreras, T., Martin-Albo, J., Kish, A., et al. (2024). Simple strategy for the simulation of axially symmetric large-area metasurfaces. J. Opt. Soc. Am. B, 41(5), 1261–1269.
Abstract: Metalenses are composed of nanostructures for focusing light and have been widely explored in many exciting applications. However, their expanding dimensions pose simulation challenges. We propose a method to simulate metalenses in a timely manner using vectorial wave and ray tracing models. We sample the metalens's radial phase gradient and locally approximate the phase profile by a linear phase response. Each sampling point is modeled as a binary blazed grating, employing the chosen nanostructure, to build a transfer function set. The metalens transmission or reflection is then obtained by applying the corresponding transfer function to the incoming field on the regions surrounding each sampling point. Fourier optics is used to calculate the scattered fields under arbitrary illumination for the vectorial wave method, and a Monte Carlo algorithm is used in the ray tracing formalism. We validated our method against finite -difference time domain simulations at 632 nm, and we were able to simulate metalenses larger than 3000 wavelengths in diameter on a personal computer.
|
|
|
ATLAS Collaboration(Aad, G. et al), Amoros, G., Bernabeu Verdu, J., Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., et al. (2010). The ATLAS Inner Detector commissioning and calibration. Eur. Phys. J. C, 70(3), 787–821.
Abstract: The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data-taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and in-situ calibrations are described. Tracking performance has been measured with 7.6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energy-loss calibration and transition radiation turn-on measurements have been performed. Different alignment techniques have been used to reconstruct the detector geometry. After the initial alignment, a transverse impact parameter resolution of 22.1 +/- 0.9 μm and a relative momentum resolution sigma (p) /p=(4.83 +/- 0.16)x10(-4) GeV(-1)xp (T) have been measured for high momentum tracks.
|
|
|
Gorkavenko, V., Jashal, B. K., Kholoimov, V., Kyselov, Y., Mendoza, D., Ovchynnikov, M., et al. (2024). LHCb potential to discover long-lived new physics particles with lifetimes above 100 ps. Eur. Phys. J. C, 84(6), 608–15pp.
Abstract: For years, it has been believed that the main LHC detectors can play only a limited role of a lifetime frontier experiment exploring the parameter space of long-lived particles (LLPs)-hypothetical particles with tiny couplings to the Standard Model. This paper demonstrates that the LHCb experiment may become a powerful lifetime frontier experiment if it uses the new Downstream algorithm reconstructing tracks that do not allow hits in the LHCb vertex tracker. In particular, for many LLP scenarios, LHCb may be as sensitive as the proposed experiments beyond the main LHC detectors for various LLP models, including heavy neutral leptons, dark scalars, dark photons, and axion-like particles.
|
|
|
Baeza-Ballesteros, J., Donini, A., Molina-Terriza, G., Monrabal, F., & Simon, A. (2024). Towards a realistic setup for a dynamical measurement of deviations from Newton's 1/r2 law: the impact of air viscosity. Eur. Phys. J. C, 84(6), 596–20pp.
Abstract: A novel experimental setup to measure deviations from the 1/r(2) distance dependence of Newtonian gravity was proposed in Donini and Marimon (Eur Phys J C 76:696, 2016). The underlying theoretical idea was to study the orbits of a microscopically-sized planetary system composed of a “Satellite”, with mass m(S) similar to O(10-9) g, and a “Planet”, with mass M-P similar to O(10-5) g at an initial distance of hundreds of microns. The detection of precession of the orbit in this system would be an unambiguous indication of a central potential with terms that scale with the distance differently from 1/r. This is a huge advantage with respect to the measurement of the absolute strength of the attraction between two bodies, as most electrically-induced background potentials do indeed scale as 1/r. Detection of orbit precession is unaffected by these effects, allowing for better sensitivities. In Baeza-Ballesteros et al. (Eur Phys J C 82:154, 2022), the impact of other subleading backgrounds that may induce orbit precession, such as, e.g., the electrical Casimir force or general relativity, was studied in detail. It was found that the proposed setup could test Yukawa-like corrections, alpha x exp(-r/lambda), to the 1/r potential with couplings as low as alpha similar to 10(-2) for distances as small as lambda similar to 10 μm, improving by roughly an order of magnitude present bounds. In this paper, we start to move from a theoretical study of the proposal to a more realistic implementation of the experimental setup. As a first step, we study the impact of air viscosity on the proposed setup and see how the setup should be modified in order to preserve the theoretical sensitivity achieved in Donini and Marimon (2016) and Baeza-Ballesteros et al. (2022).
|
|
|
Irles, A., Marquez, J. P., Pöschl, R., Richard, F., Saibel, A., Yamamoto, H., et al. (2024). Probing gauge-Higgs unification models at the ILC with quark-antiquark forward-backward asymmetry at center-of-mass energies above the Z mass. Eur. Phys. J. C, 84(5), 537–17pp.
Abstract: The International Linear Collider (ILC) will allow the precise study of e(-)e(+)-> q (q) over bar interactions at different center-of-mass energies from the Z-pole to 1 TeV. In this paper, we discuss the experimental prospects for measuring differential observables in e(-)e(+)-> b (b) over bar and e(-)e(+) -> c (c) over bar at the ILC baseline energies, 250 and 500 GeV. The study is based on full simulation and reconstruction of the International Large Detector (ILD) concept. Two gauge-Higgs unification models predicting new high-mass resonances beyond the Standard Model are discussed. These models predict sizable deviations of the forward-backward observables at the ILC running above the Z mass and with longitudinally polarized electron and positron beams. The ability of the ILC to probe these models via high-precision measurements of the forward-backward asymmetry is discussed. Alternative scenarios at other energies and beam polarization schemes are also discussed, extrapolating the estimated uncertainties from the two baseline scenarios.
|
|
|
NEXT Collaboration(Haefner, J. et al), Carcel, S., Carrion, J. V., Lopez-March, N., Martin-Albo, J., Muñoz Vidal, J., et al. (2024). Demonstration of event position reconstruction based on diffusion in the NEXT-white detector. Eur. Phys. J. C, 84(5), 518–13pp.
Abstract: Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift distance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high- and low-energy events. Using point-like energy deposits from Kr-83m calibration electron captures (E similar to 45 keV), the position of origin of low-energy events is determined to 2 cm precision with bias <1 mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E >= 1.5 MeV), from radiogenic electrons, yielding a precision of 3 cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q(beta beta) in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.
|
|
|
Bout, R., Busto, J., Cecchini, V., Charpentier, P., Chapellier, M., Dastgheibi-Fard, A., et al. (2024). Perspectives of a single-anode cylindrical chamber operating in ionization mode and high gas pressure. Eur. Phys. J. C, 84(5), 512–14pp.
Abstract: As part of the R2D2 (Rare Decays with Radial Detector) R &D, the use of a gas detector with a spherical or cylindrical cathode, equipped with a single anode and operating at high pressure, was studied for the search of rare phenomena such as neutrinoless double-beta decay. The presented measurements were obtained with a cylindrical detector, covering gas pressures ranging from 1 to 10 bar in argon and 1 to 6 bar in xenon, using both a point-like source of 210 \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<^>{210} $$\end{document} Po (5.3 MeV alpha \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\alpha $$\end{document} ) and a diffuse source of 222 \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<^>{222}$$\end{document} Rn (5.5 MeV alpha \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\alpha $$\end{document} ). Analysis and interpretation of the data were developed using the anodic current waveform. Similar detection performances were achieved with both gases, and comparable energy resolutions were measured with both sources. As long as the purity of the gas was sufficient, no significant degradation of the measured energy was observed by increasing the pressure. At the highest operating pressure, an energy resolution better than 1.5% full-width at half-maximum (FWHM) was obtained for both gaseous media, although optimal noise conditions were not reached.
|
|
|
Lin, J. X., Chen, H. X., Liang, W. H., Xiao, C. W., & Oset, E. (2024). (B)over-bars0 → Ds1(2460)+ K-, Ds1(2536)+ K- and the nature of the two Ds1 resonances. Eur. Phys. J. C, 84(4), 439–8pp.
Abstract: Starting from the molecular picture for the D-s1(2460) and D-s1(2536) resonances, which are dynamically generated by the interaction of coupled channels, the most important of which are the D* K for the D-s1(2460) and DK* for the D-s1(2536), we evaluate the ratio of decay widths for the (B) over bar (0)(s) -> D-s1(2460)(+) K- and (B) over bar (0)(s) -> D-s1(2536)(+) K- decays, the latter of which has been recently investigated by the LHCb collaboration, and we obtain a ratio of the order of unity. The present results should provide an incentive for the related decay into the D-s1(2460) resonance to be performed, which would provide valuable information on the nature of these two resonances.
|
|
|
Nacher, E., Briz, J. A., Nerio, A. N., Perea, A., Tavora, V. G., Tengblad, O., et al. (2024). Characterization of a novel proton-CT scanner based on Silicon and LaBr3(Ce) detectors. Eur. Phys. J. Plus, 139(5), 404–9pp.
Abstract: Treatment planning systems at proton-therapy centres entirely use X-ray computed tomography (CT) as primary imaging technique to infer the proton treatment doses to tumour and healthy tissues. However, proton stopping powers in the body, as derived from X-ray images, suffer from important proton-range uncertainties. In order to reduce this uncertainty in range, one could use proton-CT images instead. The main goal of this work is to test the capabilities of a newly-developed proton-CT scanner, based on the use of a set of tracking detectors and a high energy resolution scintillator for the residual energy of the protons. Different custom-made phantoms were positioned at the field of view of the scanner and were irradiated with protons at the CCB proton-therapy center in Krakow. We measured with the phantoms at different angles and produced sinograms that were used to obtain reconstructed images by Filtered Back-Projection. The obtained images were used to determine the capabilities of our scanner in terms of spatial resolution and proton Relative Stopping Power (RSP) mapping and validate its use as proton-CT scanner. The results show that the scanner can produce medium-high quality images, with spatial resolution better than 2 mm in radiography, below 3 mm in tomography and resolving power in the RSP comparable to other state-of-the-art pCT scanners.
|
|
|
Maluf, R. V., Mora-Perez, G., Olmo, G. J., & Rubiera-Garcia, D. (2024). Nonsingular, Lump-like, Scalar Compact Objects in (2+1)-Dimensional Einstein Gravity. Universe, 10(6), 258–13pp.
Abstract: We study the space-time geometry generated by coupling a free scalar field with a noncanonical kinetic term to general relativity in (2+1) dimensions. After identifying a family of scalar Lagrangians that yield exact analytical solutions in static and circularly symmetric scenarios, we classify the various types of solutions and focus on a branch that yields asymptotically flat geometries. We show that the solutions within such a branch can be divided in two types, namely naked singularities and nonsingular objects without a center. In the latter, the energy density is localized around a maximum and vanishes only at infinity and at an inner boundary. This boundary has vanishing curvatures and cannot be reached by any time-like or null geodesic in finite affine time. This allows us to consistently interpret such solutions as nonsingular, lump-like, static compact scalar objects whose eventual extension to the (3+1)-dimensional context could provide structures of astrophysical interest.
|
|