|
Kucuk, L. et al, Orrigo, S. E. A., Montaner-Piza, A., Rubio, B., Gelletly, W., Algora, A., et al. (2017). Half-life determination of T-z =-1 and T-z =-1/2 proton-rich nuclei and the beta decay of Zn-58. Eur. Phys. J. A, 53(6), 134–10pp.
Abstract: We have measured the beta-decay half-lives of 16 neutron-deficient nuclei with T-z = -1/2 and -1, ranging from chromium to germanium. They were produced in an experiment carried out at GANIL and optimized for the production of Zn-58, for which in addition we present the decay scheme and absolute Fermi and Gamow-Teller transition strengths. Since all of these nuclei lie on the rp-process pathway, the T-1/2 values are important ingredients for the rp-process reaction flow calculations and for models of X-ray bursters.
|
|
|
Algora, A., Tain, J. L., Rubio, B., Fallot, M., & Gelletly, W. (2021). Beta-decay studies for applied and basic nuclear physics. Eur. Phys. J. A, 57(3), 85–28pp.
Abstract: In this reviewwe will present the results of recent beta-decay studies using the total absorption technique that cover topics of interest for applications, nuclear structure and astrophysics. The decays studied were selected primarily because they have a large impact on the prediction of (a) the decay heat in reactors, important for the safety of present and future reactors and (b) the reactor electron anti-neutrino spectrum, of interest for particle/nuclear physics and reactor monitoring. For these studies the total absorption technique was chosen, since it is the only method that allows one to obtain beta-decay probabilities free from a systematic error called the Pandemonium effect. The total absorption technique is based on the detection of the. cascades that follow the initial beta decay. For this reason the technique requires the use of calorimeters with very high. detection efficiency. The measurements presented and discussed here were performed mainly at the IGISOL facility of the University of Jyvaskyla (Finland) using isotopically pure beams provided by the JYFLTRAP Penning trap. Examples are presented to show that the results of our measurements on selected nuclei have had a large impact on predictions of both the decay heat and the anti-neutrino spectrum from reactors. Some of the cases involve beta-delayed neutron emission thus one can study the competition between gamma – and neutron-emission from states above the neutron separation energy. The gamma-to-neutron emission ratios can be used to constrain neutron capture (n, gamma) cross sections for unstable nuclei of interest in astrophysics. The information obtained from the measurements can also be used to test nuclear model predictions of half-lives and Pn values for decays of interest in astrophysical network calculations. These comparisons also provide insights into aspects of nuclear structure in particular regions of the nuclear chart.
|
|
|
Guadilla, V. et al, Tain, J. L., Algora, A., Agramunt, J., Gelletly, W., Jordan, D., et al. (2018). Characterization and performance of the DTAS detector. Nucl. Instrum. Methods Phys. Res. A, 910, 79–89.
Abstract: DTAS is a segmented total absorption y-ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory sources and also under real experimental conditions. We present a procedure to reconstruct offline the sum of the energy deposited in all the crystals of the spectrometer, which is complicated by the effect of NaI(Tl) light-yield non-proportionality. The use of a system to correct for time variations of the gain in individual detector modules, based on a light pulse generator, is demonstrated. We describe also an event-based method to evaluate the summing-pileup electronic distortion in segmented spectrometers. All of this allows a careful characterization of the detector with Monte Carlo simulations that is needed to calculate the response function for the analysis of total absorption gamma-ray spectroscopy data. Special attention was paid to the interaction of neutrons with the spectrometer, since they are a source of contamination in studies of beta-delayed neutron emitting nuclei.
|
|
|
Tain, J. L., Algora, A., Agramunt, J., Guadilla, V., Jordan, M. D., Montaner-Piza, A., et al. (2015). A decay total absorption spectrometer for DESPEC at FAIR. Nucl. Instrum. Methods Phys. Res. A, 803, 36–46.
Abstract: This paper presents the design of a total absorption gamma-ray spectrometer for the determination of beta-decay intensity distributions of exotic nuclear species at the focal plane of the FAIR-NUSTAR Super Fragment Separator. The spectrometer is a key instrument in the DESPEC experiment and the proposed implementation follows extensive design studies and prototype tests. Two options were contemplated, based on Nal(TI) and LaBr3:Ce inorganic scintillation crystals respectively. Monte Carlo simulations and technical considerations determined the optimal configurations consisting of sixteen 15 x 15 x 25 cm(3) crystals for the Nal(Tl) option and one hundred and twenty-eight 5.5 x 5.5 x 11 cm(3) crystals for the LaBr3:Ce option. Minimization of dead material was crucial for maximizing the spectrometer full-energy peak efficiency. Module prototypes were build to verify constructional details and characterize their performance. The measured energy and timing resolution was found to agree rather well with estimates based on simulations of scintillation light transport and collection. The neutron sensitivity of the spectrometer, important when measuring beta-delayed neutron emitters, was investigated by means of Monte Carlo simulations.
|
|