Richard, J. M., Valcarce, A., & Vijande, J. (2020). Hall-Post inequalities: Review and application to molecules and tetraquarks. Ann. Phys., 412, 168009–32pp.
Abstract: A review is presented of the Hall-Post inequalities that give lower-bounds to the ground-state energy of quantum systems in terms of energies of smaller systems. New applications are given for systems experiencing both a static source and inner interactions, as well as for hydrogen-like molecules and for tetraquarks in some quark models. In the latter case, the Hall-Post inequalities constrain the possibility of deeply-bound exotic mesons below the threshold for dissociation into two quark-antiquark mesons. We also emphasize the usefulness of the Hall-Post bounds in terms of 3-body energies when some 2-body subsystems are ill defined or do not support any bound state.
|
Gimenez-Alventosa, V., Gimenez, V., Ballester, F., Vijande, J., & Andreo, P. (2020). Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams. Phys. Med. Biol., 65(20), 205005–11pp.
Abstract: The beam quality correction factork(Q)for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed on the widely used NE-2571 ionization chamber have been used to benchmark the results. The Monte Carlo code PENELOPE/penEasy was used to calculate the absorbed dose to a point in water and the absorbed dose to the active air volume of the chambers for photon beams in the range 4 to 24 MV. Of the nine ionization chambers analysed, only five are included in the current version of the International Code of Practice for dosimetry based on standards of absorbed dose to water (IAEA TRS 398). The values reported in this work agree with those in the literature within the uncertainty estimates and are to be included in the average values of the data obtained by different working groups for the forthcoming update of TRS 398.
|
Richard, J. M., Valcarce, A., & Vijande, J. (2020). Very Heavy Flavored Dibaryons. Phys. Rev. Lett., 124(21), 212001–4pp.
Abstract: We explore the possibility of very heavy dibaryons with three charm quarks and three beauty quarks, bbbccc, using a constituent model which should lead to the correct solution in the limit of hadrons made of heavy quarks. The six-body problem is treated rigorously, in particular taking into account the orbital, color, and spin mixed-symmetry components of the wave function. Unlike a recent claim based on lattice QCD, no bound state is found below the lowest dissociation threshold.
|
Valdes-Cortez, C., Ballester, F., Vijande, J., Gimenez, V., Gimenez-Alventosa, V., Perez-Calatayud, J., et al. (2020). Depth-dose measurement corrections for the surface electronic brachytherapy beams of an Esteya(R) unit: a Monte Carlo study. Phys. Med. Biol., 65(24), 245026–12pp.
Abstract: Three different correction factors for measurements with the parallel-plate ionization chamber PTW T34013 on the Esteya electronic brachytherapy unit have been investigated. This chamber type is recommended by AAPM TG-253 for depth-dose measurements in the 69.5 kV x-ray beam generated by the Esteya unit. Monte Carlo simulations using the PENELOPE-2018 system were performed to determine the absorbed dose deposited in water and in the chamber sensitive volume at different depths with a Type A uncertainty smaller than 0.1%. Chamber-to-chamber differences have been explored performing measurements using three different chambers. The range of conical applicators available, from 10 to 30 mm in diameter, has been explored. Using a depth-independent global chamber perturbation correction factor without a shift of the effective point of measurement yielded differences between the absorbed dose to water and the corrected absorbed dose in the sensitive volume of the chamber of up to 1% and 0.6% for the 10 mm and 30 mm applicators, respectively. Calculations using a depth-dependent perturbation factor, including or excluding a shift of the effective point of measurement, resulted in depth-dose differences of about +/- 0.5% or less for both applicators. The smallest depth-dose differences were obtained when a shift of the effective point of measurement was implemented, being displaced 0.4 mm towards the center of the sensitive volume of the chamber. The correction factors were obtained with combined uncertainties of 0.4% (k = 2). Uncertainties due to chamber-to-chamber differences are found to be lower than 2%. The results emphasize the relevance of carrying out detailed Monte Carlo studies for each electronic brachytherapy device and ionization chamber used for its dosimetry.
|
Vijande, J., Valcarce, A., Carames, T. F., & Garcilazo, H. (2013). Heavy Hadron Spectroscopy: A Quark Model Perspective. Int. J. Mod. Phys. E, 22(5), 1330011–25pp.
Abstract: We present recent results of hadron spectroscopy and hadron hadron interaction from the perspective of constituent quark models. We pay special attention to the role played by higher-order hock space components in the hadron spectra and the connection of this extension with the hadron-hadron interaction. The main goal of our description is to obtain a coherent understanding of the low-energy hadron phenomenology without enforcing any particular model, to constrain its characteristics and learn about the low-energy realization of the theory.
|