Records |
Author |
AGATA Collaboration; Domingo-Pardo, C.; Bazzacco, D.; Doornenbal, P.; Farnea, E.; Gadea, A.; Gerl, J.; Wollersheim, H.J. |
Title |
Conceptual design and performance study for the first implementation of AGATA at the in-flight RIB facility of GSI |
Type |
Journal Article |
Year |
2012 |
Publication |
Nuclear Instruments & Methods in Physics Research A |
Abbreviated Journal |
Nucl. Instrum. Methods Phys. Res. A |
Volume |
694 |
Issue |
|
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
297-312 |
Keywords |
gamma-Ray spectroscopy; Tracking; Monte Carlo |
Abstract |
The main objective of the Advanced GAmma Tracking Array (AGATA) is the investigation of the structure of exotic nuclei at the new generation of RIB facilities. As part of the preparatory phase for FAIR-NUSTAR, AGATA is going to be installed at the FRS fragmentation facility of the GSI centre for an experimental campaign to be performed in 2012 and 2013. Owing to its gamma-ray tracking capabilities and the envisaged enhancement in resolving power, a series of in-flight gamma-ray spectroscopy experiments are being planned. The present work describes the conceptual design of this first implementation of AGATA at GSI-FRS, and provides information about the expected performance figures. According to the characteristics of each particular experiment, it is foreseen that the target-array distance is adjusted in order to achieve the optimum compromise between detection efficiency and energy resolution, or to cover an specific angular range of the emitted electromagnetic radiation. Thus, a comprehensive Monte Carlo study of the detection sensitivity in terms of photopeak efficiency, resolution and peak-to-total ratio, as a function of the target-array distance is presented. Several configurations have been investigated, and MC-calculations indicate that a remarkable enhancement in resolving power can be achieved when double-cluster AGATA detectors are developed and implemented. Several experimental effects are also investigated. This concerns the impact of passive materials between the target and the array, the angular distribution of the detection efficiency and the influence of target thickness effects and transition lifetimes in the attainable detection sensitivity. A short overview on half-life measurements via lineshape effects utilizing AGATA is also presented. (C) 2012 Elsevier B.V. All rights reserved. |
Address |
[Domingo-Pardo, C.; Gadea, A.] Univ Valencia, CSIC, IFIC, Valencia, Spain, Email: domingo@ific.uv.es |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0168-9002 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000311020500041 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
1240 |
Permanent link to this record |
|
|
|
Author |
Llosa, G. |
Title |
Recent developments in photodetection for medical applications |
Type |
Journal Article |
Year |
2015 |
Publication |
Nuclear Instruments & Methods in Physics Research A |
Abbreviated Journal |
Nucl. Instrum. Methods Phys. Res. A |
Volume |
787 |
Issue |
|
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
353-357 |
Keywords |
Detectors; Photodetectors; Medical applications; PET; SPECT; Hadron Therapy |
Abstract |
The use of the most advanced technology in medical imaging results in the development of high performance detectors that can significantly improve the performance of the medical devices employed in hospitals. Scintillator crystals coupled to photodetectors remain to be essential detectors in terms of performance and cost for medical imaging applications in different imaging modalities. Recent advances in photodetectors result in an increase of the performance of the medical scanners. Solid state detectors can provide substantial performance improvement, but are more complex to integrate into clinical detectors due mainly to their higher cost. Solid state photodetectors (APDs, SiPMs) have made new detector concepts possible and have led to improvements in different imaging modalities. Recent advances in detectors for medical imaging are revised. |
Address |
UVEG, CSIC, Inst Fis Corpuscular, Valencia, Spain, Email: gabriela.llosa@ific.uv.es |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0168-9002 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000354869900079 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
no |
Call Number |
IFIC @ pastor @ |
Serial |
2233 |
Permanent link to this record |
|
|
|
Author |
Wimmer, K. et al; Algora, A.; Rubio, B. |
Title |
Shape coexistence and isospin symmetry in A=70 nuclei: Spectroscopy of the T-z =-1 nucleus Kr-70 |
Type |
Journal Article |
Year |
2018 |
Publication |
Physics Letters B |
Abbreviated Journal |
Phys. Lett. B |
Volume |
785 |
Issue |
|
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
441-446 |
Keywords |
Radioactive beams; Gamma-ray spectroscopy; Mirror symmetry; Shape coexistence |
Abstract |
Excited states in the T-z = -1 nucleus Kr-70 have been populated using inelastic scattering of a radioactive Kr-70 beam as well as one- and two-neutron removal reactions from Kr-71,Kr-72 at intermediate beam energies. The level scheme of Kr-70 was constructed from the observed gamma-ray transitions and coincidences. Tentative spin and parity assignments were made based on comparison with the mirror nucleus Se-70. Asecond 2(+) state and a candidate for the corresponding 4(2)(+) state suggest shape coexistence in Kr-70. |
Address |
[Wimmer, K.; Ando, T.; Koyama, S.; Nagamine, S.; Niikura, M.; Saito, T. Y.; Sakurai, H.; Taniuchi, R.] Univ Tokyo, Dept Phys, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1130033, Japan, Email: wimmer@phys.s.u-tokyo.ac.jp |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0370-2693 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000447424000064 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
3795 |
Permanent link to this record |
|
|
|
Author |
Nieves, J.; Sobczyk, J.E. |
Title |
In medium dispersion relation effects in nuclear inclusive reactions at intermediate and low energies |
Type |
Journal Article |
Year |
2017 |
Publication |
Annals of Physics |
Abbreviated Journal |
Ann. Phys. |
Volume |
383 |
Issue |
|
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
455-496 |
Keywords |
Neutrino-nucleus scattering; Quasielastic mechanism; Spectral function; RPA; Muon capture; Radiative pion capture |
Abstract |
In a well-established many-body framework, successful in modeling a great variety of nuclear processes, we analyze the role of the spectral functions (SFs) accounting for the modifications of the dispersion relation of nucleons embedded in a nuclear medium. We concentrate in processes mostly governed by one-body mechanisms, and study possible approximations to evaluate the particle hole propagator using SFs. We also investigate how to include together SFs and long-range RPA-correlation corrections in the evaluation of nuclear response functions, discussing the existing interplay between both type of nuclear effects. At low energy transfers (<= 50 MeV), we compare our predictions for inclusive muon and radiative pion captures in nuclei, and charge-current (CC) neutrino-nucleus cross sections with experimental results. We also present an analysis of intermediate energy quasi-elastic neutrino scattering for various targets and both neutrino and antineutrino CC driven processes. In all cases, we pay special attention to estimate the uncertainties affecting the theoretical predictions. In particular, we show that errors on the a,,sigma(mu)/sigma(e) ratio are much smaller than 5%, and also much smaller than the size of the SF+RPA nuclear corrections, which produce significant effects, not only in the individual cross sections, but also in their ratio for neutrino energies below 400 MeV. These latter nuclear corrections, beyond Pauli blocking, turn out to be thus essential to achieve a correct theoretical understanding of this ratio of cross sections of interest for appearance neutrino oscillation experiments. We also briefly compare our SF and RPA results to predictions obtained within other representative approaches. |
Address |
[Nieves, Juan] Univ Valencia, CSIC,Ctr Mixto, Inst Invest Paterna, Inst Fis Corpuscular IFIC, Apartado 22085, E-46071 Valencia, Spain, Email: jmnieves@ific.uv.es |
Corporate Author |
|
Thesis |
|
Publisher |
Academic Press Inc Elsevier Science |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0003-4916 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000407667300025 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
3244 |
Permanent link to this record |
|
|
|
Author |
Menjo, H. et al; Faus-Golfe, A.; Velasco, J. |
Title |
Monte Carlo study of forward pi(0) production spectra to be measured by the LHCf experiment for the purpose of benchmarking hadron interaction models at 10(17) eV |
Type |
Journal Article |
Year |
2011 |
Publication |
Astroparticle Physics |
Abbreviated Journal |
Astropart Phys. |
Volume |
34 |
Issue |
7 |
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
513-520 |
Keywords |
High energy cosmic rays; LHC; LHCf; High energy pi(0) production spectra |
Abstract |
The LHCf experiment aims to improve knowledge of forward neutral particle production spectra at the LHC energy which is relevant for the interpretation of air shower development of high energy cosmic rays. Two detectors, each composed of a pair of sampling and imaging calorimeters, have been installed at the forward region of IP1 to measure pi(0) energy spectra above 600 GeV. In this paper, we present a Monte Carlo study of the pi(0) measurements to be performed with one of the LHCf detectors for proton-proton collisions at root s = 14 TeV. In approximately 40 min of operation at luminosity 0.8 x 10(29) cm(-2) s(-1) during the beam commissioning phase of LHC, about 1.5 x 10(4) pi(0) events are expected to be obtained at two transverse positions of the detector. The backgrounds from interactions of secondary particles with beam pipes and interactions of beam particles with residual gas in the beam pipes are expected to be less than 0.1% of the signal from pi(0)s. We also discuss the capability of LHCf measurements to discriminate between the various hadron interaction models that are used for simulation of high energy air showers, such as DPMJET3.03, QGSJETII-03, SIBYLL2.1 and EPOS1.99. |
Address |
[Menjo, H.; Adriani, O.; Bonechi, L.; Bongi, M.; Castellini, G.; D'Alessandro, R.; Papini, P.; Ricciarini, S.; Viciani, A.] Ist Nazl Fis Nucl, Sez Firenze, I-50019 Florence, Italy, Email: menjo@fi.infn.it |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0927-6505 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
ISI:000287955500001 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
596 |
Permanent link to this record |
|
|
|
Author |
AGATA Collaboration; Doncel, M.; Recchia, F.; Quintana, B.; Gadea, A.; Farnea, E. |
Title |
Experimental test of the background rejection, through imaging capability, of a highly segmented AGATA germanium detector |
Type |
Journal Article |
Year |
2010 |
Publication |
Nuclear Instruments & Methods in Physics Research A |
Abbreviated Journal |
Nucl. Instrum. Methods Phys. Res. A |
Volume |
622 |
Issue |
3 |
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
614-618 |
Keywords |
Gamma spectroscopy; Gamma tracking; Imaging; Position-sensitive germanium detectors |
Abstract |
The development of highly segmented germanium detectors as well as the algorithms to identify the position of the interaction within the crystal opens the possibility to locate the gamma-ray source using Compton imaging algorithms. While the Compton-suppression shield, coupled to the germanium detector in conventional arrays, works also as an active filter against the gamma rays originated outside the target, the new generation of position sensitive gamma-ray detector arrays has to fully rely on tracking capabilities for this purpose. In specific experimental conditions, as the ones foreseen at radioactive beam facilities, the ability to discriminate background radiation improves the sensitivity of the gamma spectrometer. In this work we present the results of a measurement performed at the Laboratori Nazionali di Legnaro (LNL) aiming the evaluation of the AGATA detector capabilities to discriminate the origin of the gamma rays on an event-by-event basis. It will be shown that, exploiting the Compton scattering formula, it is possible to track back gamma rays coming from different positions, assigning them to specific emitting locations. These imaging capabilities are quantified for a single crystal AGATA detector. |
Address |
[Doncel, M.; Quintana, B.] Univ Salamanca, Lab Radiac Ionizantes, E-37008 Salamanca, Spain, Email: doncel@usal.es |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0168-9002 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
ISI:000282562700017 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
257 |
Permanent link to this record |
|
|
|
Author |
Linhart, V.; Burdette, D.; Chessi, E.; Cindro, V.; Clinthorne, N.H.; Cochran, E.; Grosicar, B.; Honscheid, K.; Kagan, H.; Lacasta, C.; Llosa, G.; Mikuz, M.; Stankova, V.; Studen, A.; Weilhammer, P.; Zontar, D. |
Title |
Spectroscopy study of imaging devices based on silicon Pixel Array Detector coupled to VATAGP7 read-out chips |
Type |
Journal Article |
Year |
2011 |
Publication |
Journal of Instrumentation |
Abbreviated Journal |
J. Instrum. |
Volume |
6 |
Issue |
|
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
C01092 - 8pp |
Keywords |
Gamma camera, SPECT, PET PET/CT, coronary CT angiography (CTA); Compton imaging |
Abstract |
Spectroscopic and timing response studies have been conducted on a detector module consisting of a silicon Pixel Array Detector bonded on two VATAGP7 read-out chips manufactured by Gamma-Medica Ideas using laboratory gamma sources and the internal calibration facilities (the calibration system of the read-out chips). The performed tests have proven that the chips have (i) non-linear calibration curves which can be approximated by power functions, (ii) capability to measure the energy of photons with energy resolution better than 2 keV (exact range and resolution depend on experimental setup), (iii) the internal calibration facility which provides 6 out of 16 available internal calibration charges within our region of interest (spanning the Compton edge of 511 keV photons). The peaks induced by the internal calibration facility are suitable for a fit of the calibration curves. However, they are not suitable for measurements of equivalent noise charge because their full width at half maximum varies with their amplitude. These facts indicate that the VATAGP7 chips are useful and precise tools for a wide variety of spectroscopic devices. We have also explored time walk of the module and peaking time of the spectroscopy signals provided by the chips. We have observed that (iv) the time walk is caused partly by the peaking time of the signals provided by the fast shaper of the chips and partly by the timing uncertainty related to the varying position of the photon interaction, (v) the peaking time of the spectroscopy signals provided by the chips increases with increasing pulse height. |
Address |
[Linhart, V.; Lacasta, C.; Llosa, G.; Stankova, V.] UVEG, CSIC, IFIC, Expt Phys Dept,Inst Fis Corpuscular, E-46071 Valencia, Spain, Email: Vladimir.Linhart@ific.uv.es |
Corporate Author |
|
Thesis |
|
Publisher |
Iop Publishing Ltd |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1748-0221 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
ISI:000291345600097 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ elepoucu @ |
Serial |
645 |
Permanent link to this record |
|
|
|
Author |
LHCb Collaboration (Aaij, R. et al); Henry, L.; Jashal, B.K.; Martinez-Vidal, F.; Oyanguren, A.; Remon Alepuz, C.; Ruiz Vidal, J. |
Title |
Evidence of a J/psi Lambda structure and observation of excited Xi(-) states in the Xi(-)(b) -> J/psi Lambda K- decay |
Type |
Journal Article |
Year |
2021 |
Publication |
Science Bulletin |
Abbreviated Journal |
Sci. Bull. |
Volume |
66 |
Issue |
13 |
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
1278-1287 |
Keywords |
QCD; Exotics; Pentaquark; Spectroscopy; Quarkonium; Particle and resonance production |
Abstract |
First evidence of a structure in the J/psi Lambda invariant mass distribution is obtained from an amplitude analysis of Xi(-)(b) -> J/psi Lambda K- decays. The observed structure is consistent with being due to a charmonium pentaquark with strangeness with a significance of 3.1r including systematic uncertainties and lookelsewhere effect. Its mass and width are determined to be 4458.8 +/- 2.9(-1.1)(+4.7) MeV and 17.3 +/- 6.5(-5.7)(+8.0) MeV, respectively, where the quoted uncertainties are statistical and systematic. The structure is also consistent with being due to two resonances. In addition, the narrow excited Xi(-) states, Xi(-)(1690) and Xi(-)(1820)(-), are seen for the first time in a Xi(-)(b) decay, and their masses and widths are measured with improved precision. The analysis is performed using pp collision data corresponding to a total integrated luminosity of 9 fb(-1), collected with the LHCb experiment at centre-of-mass energies of 7, 8 and 13 TeV. |
Address |
[Leite, J. Baptista; Bediaga, I; Torres, M. Cruz; De Miranda, J. M.; dos Reis, A. C.; Gomes, A.; Massafferri, A.; Machado, D. Torres] Ctr Brasileiro Pesquisas Fis CBPF, Rio De Janeiro, Brazil |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
2095-9273 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000668689800009 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
4888 |
Permanent link to this record |
|
|
|
Author |
Algora, A. et al; Jordan, D.; Tain, J.L.; Rubio, B.; Agramunt, J.; Perez-Cerdan, A.B.; Molina, F.; Caballero, L.; Nacher, E. |
Title |
Improvements on Decay Heat Summation Calculations by Means of Total Absorption Gamma-ray Spectroscopy Measurements |
Type |
Journal Article |
Year |
2011 |
Publication |
Journal of the Korean Physical Society |
Abbreviated Journal |
J. Korean Phys. Soc. |
Volume |
59 |
Issue |
2 |
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
1479-1482 |
Keywords |
Decay heat; Total absorption; Trap-assisted spectroscopy |
Abstract |
The decay heat of fission products plays an important role in predictions of the heat released by nuclear fuel in reactors. In this contribution we present results of the analysis of the measurement of the beta decay of some refractory isotopes that were considered possible important contributors to the decay heat in reactors. The measurements presented here were performed at the IGISOL facility of the University of Jyvaskyla, Finland. In our measurements we have combined for the first time a Penning trap (JYFLTRAP), which was used as a high resolution isobaric separator, with a total absorption spectrometer. The results of the measurements as well as their consequences for decay heat summation calculations are discussed. |
Address |
[Algora, A; Jordan, D; Tain, JL; Rubio, B; Agramunt, J; Caballero, L; Nacher, E; Perez-Cerdan, AB; Molina, F] Univ Valencia, CSIC, IFIC, Valencia, Spain, Email: algora@ific.uv.es |
Corporate Author |
|
Thesis |
|
Publisher |
Korean Physical Soc |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0374-4884 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000294080700005 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ elepoucu @ |
Serial |
729 |
Permanent link to this record |
|
|
|
Author |
Tain, J.L. et al; Algora, A.; Estevez, E.; Rubio, B.; Valencia, E.; Jordan, D. |
Title |
Beta Decay Studies of Neutron Rich Nuclei Using Total Absorption Gamma-ray Spectroscopy and Delayed Neutron Measurements |
Type |
Journal Article |
Year |
2011 |
Publication |
Journal of the Korean Physical Society |
Abbreviated Journal |
J. Korean Phys. Soc. |
Volume |
59 |
Issue |
2 |
Pages ![sorted by First Page field, ascending order (up)](img/sort_asc.gif) |
1499-1502 |
Keywords |
Beta decay; Delayed neutron emission; Total absorption gamma-ray spectroscopy; Neutron detectors; Nuclear technology; Nuclear astrophysics |
Abstract |
A complete characterisation of the beta-decay of neutron-rich nuclei can be obtained from the measurement of beta-delayed gamma rays and, whenever the process is energetically possible, beta-delayed neutrons. The accurate determination of the beta-intensity distribution and the beta-delayed neutron emission probability is of great relevance in the fields of reactor technology and nuclear astrophysics. A programme for combined measurements using the total absorption gamma-ray spectroscopy technique and both neutron counters and neutron time-of-flight spectrometers is presented. |
Address |
[Tain, JL; Algora, A; Estevez, E; Rubio, B; Valencia, E; Jordan, D] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia 46071, Spain, Email: tain@ific.uv.es |
Corporate Author |
|
Thesis |
|
Publisher |
Korean Physical Soc |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
0374-4884 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000294080700010 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ elepoucu @ |
Serial |
730 |
Permanent link to this record |