Guadilla, V. et al, Algora, A., Tain, J. L., Agramunt, J., Jordan, D., Monserrate, M., et al. (2017). Characterization of a cylindrical plastic beta-detector with Monte Carlo simulations of optical photons. Nucl. Instrum. Methods Phys. Res. A, 854, 134–138.
Abstract: In this work we report on the Monte Carlo study performed to understand and reproduce experimental measurements of a new plastic beta-detector with cylindrical geometry. Since energy deposition simulations differ from the experimental measurements for such a geometry, we show how the simulation of production and transport of optical photons does allow one to obtain the shapes of the experimental spectra. Moreover, taking into account the computational effort associated with this kind of simulation, we develop a method to convert the simulations of energy deposited into light collected, depending only on the interaction point in the detector. This method represents a useful solution when extensive simulations have to be done, as in the case of the calculation of the response function of the spectrometer in a total absorption gamma-ray spectroscopy analysis.
|
|
|
Kucuk, L. et al, Orrigo, S. E. A., Montaner-Piza, A., Rubio, B., Gelletly, W., Algora, A., et al. (2017). Half-life determination of T-z =-1 and T-z =-1/2 proton-rich nuclei and the beta decay of Zn-58. Eur. Phys. J. A, 53(6), 134–10pp.
Abstract: We have measured the beta-decay half-lives of 16 neutron-deficient nuclei with T-z = -1/2 and -1, ranging from chromium to germanium. They were produced in an experiment carried out at GANIL and optimized for the production of Zn-58, for which in addition we present the decay scheme and absolute Fermi and Gamow-Teller transition strengths. Since all of these nuclei lie on the rp-process pathway, the T-1/2 values are important ingredients for the rp-process reaction flow calculations and for models of X-ray bursters.
|
|
|
XENON Collaboration(Aprile, E. et al), & Orrigo, S. E. A. (2017). Removing krypton from xenon by cryogenic distillation to the ppq level. Eur. Phys. J. C, 77(5), 275–12pp.
Abstract: The XENON1T experiment aims for the direct detection of dark matter in a detector filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the beta-emitter Kr-85 which is present in the xenon. For XENON1T a concentration of natural krypton in xenon Kr-nat/Xe < 200 ppq (parts per quadrillion, 1 ppq = 10(-15) mol/mol) is required. In this work, the design, construction and test of a novel cryogenic distillation column using the common McCabe-Thiele approach is described. The system demonstrated a krypton reduction factor of 6.4 . 10(5) with thermodynamic stability at process speeds above 3 kg/h. The resulting concentration of natKr/Xe < 26 ppq is the lowest ever achieved, almost one order of magnitude below the requirements for XENON1T and even sufficient for future dark matter experiments using liquid xenon, such as XENONnT and DARWIN.
|
|
|
Cappuzzello, F., Rea, C., Bonaccorso, A., Bondi, M., Carbone, D., Cavallaro, M., et al. (2012). New structures in the continuum of C-15 populated by two-neutron transfer. Phys. Lett. B, 711(5), 347–352.
Abstract: The C-13(O-18,O-16)C-15 reaction has been studied at 84 MeV incident energy. The ejectiles have been detected at forward angles and C-15 excitation energy spectra have been obtained up to about 20 MeV. Several known bound and resonant states of C-15 have been identified together with two unknown structures at 10.5 MeV (FWHM = 2.5 MeV) and 13.6 MeV (FWHM = 2.5 MeV). Calculations based Oil the removal of two uncorrelated neutrons from the projectile describe a significant part of the continuum observed in the energy spectra. In particular the structure at 10.5 MeV is dominated by a resonance of C-15 near the C-13 + n + n threshold. Similar structures are found in nearby nuclei such as C-14 and Be-11.
|
|
|
XENON Collaboration(Aprile, E. et al), & Orrigo, S. E. A. (2017). Online Rn-222 removal by cryogenic distillation in the XENON100 experiment. Eur. Phys. J. C, 77(6), 358–8pp.
Abstract: We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column was integrated into the gas purification loop of the XENON100 detector for online radon removal. This enabled us to significantly reduce the constant Rn-222 background originating from radon emanation. After inserting an auxiliary 222Rn emanation source in the gas loop, we determined a radon reduction factor of R > 27 (95% C.L.) for the distillation column by monitoring the Rn-222 activity concentration inside the XENON100 detector.
|
|