Ertoprak, A. et al, Algora, A., Gadea, A., & Huyuk, T. (2018). M1 and E2 transition rates from core-excited states in semi-magic Ru-94. Eur. Phys. J. A, 54(9), 145–9pp.
Abstract: Lifetimes of high-spin states have been measured in the semi-magic (N = 50) nucleus Ru-94. Excited states in Ru-94 were populated in the Ni-58(Ca-40, 4p)Ru-94* fusion-evaporation reaction at the Grand Accelerateur National d'Ions Lourds (GANIL) accelerator complex. DSAM lifetime analysis was performed on the Doppler broadened line shapes in energy spectra obtained from gamma-rays emitted while the residual nuclei were slowing down in a thick 6 mg/cm(2) metallic Ni-58 target. In total eight excited-state lifetimes in the angular momentum range I = (13-20)h have been measured, five of which were determined for the first time. The corresponding B(M1) and B(E2) reduced transition strengths are discussed within the framework of large-scale shell model calculations to study the contribution of different particle-hole configurations, in particular for analyzing contributions from core-excited configurations.
|
Clement, E., Bracco, A., Gadea, A., & Simpson, J. (2023). Organisation of the AGATA collaboration and physics campaigns. Eur. Phys. J. A, 59(7), 152–5pp.
Abstract: The AGATA spectrometer has a well-established organisational and management structure for its construction and operation. The roles and responsibilities of each of the management committees and their interaction, as well as the scientific organisation is described in this contribution. The organisation of the present campaign, which aims to realise the 4p spectrometer, is presented. General comments on the previous physics campaigns at LNL (2010-2011), GSI (2012-2014) and GANIL (2015-2021) are made.
|
Colovic, P. et al, & Gadea, A. (2017). Stretched configuration of states as inferred from gamma-ray angular distributions in Ar-40+Pb-208 neutron transfer reactions. Eur. Phys. J. A, 53(8), 166–6pp.
Abstract: Angular distributions of.-rays for selected transitions in Ar-40,Ar-41,Ar-42 isotopes have been studied with the PRISMA magnetic spectrometer coupled to the CLARA gamma array. These transitions were populated in Ar isotopes reached via neutron transfer in the Ar-40 + Pb-208 reaction. By comparison with the shape of the experimental angular distribution of the known E2 transitions we established more firmly the spin and parity of excited states. In particular, in Ar-41 for the (11/2(-)) state through the (11/2(-)) -> 7/2(-) transition whose structure was discussed in terms of a phonon-fermion coupled state. The comparison with the expected fully aligned spin indicated that a high level of spin alignment has been reached.
|
Bertoldo, S., Maggioni, G., Raniero, W., Carraro, C., Riccetto, S., Sgarbossa, F., et al. (2021). New method for the production of thin and stable, segmented n plus contacts in HPGe detectors. Eur. Phys. J. A, 57(6), 177–10pp.
Abstract: The realization of pulsed-laser diffused, thin n+ contacts on high purity germanium (HPGe) and their successful segmentation is described. The contacts have been obtained by a laser-induced diffusion of Sb atoms, deposited by sputtering on Ge surface, and then segmented by means of a photolithographic technique. Three small prototypes of gamma ray detectors have been implemented, using the same n+ contact (laser diffused Sb) but with three different geometries and a B implanted p+ contact. Electrical and detection properties of the prototypes have been characterized, showing low leakage currents and good spectroscopy data with different gamma-ray sources. The stability of the detector performance has also been tested subjecting one of the prototypes to a typical annealing treatment.
|
Capra, S., Mengoni, D., Dueñas, J. A., John, P. R., Gadea, A., Aliaga, R. J., et al. (2019). Performance of the new integrated front-end electronics of the TRACE array commissioned with an early silicon detector prototype. Nucl. Instrum. Methods Phys. Res. A, 935, 178–184.
Abstract: The spectroscopic performances of the new integrated ASIC (Application-Specific Integrated Circuit) preamplifiers for highly segmented silicon detectors have been evaluated with an early silicon detector prototype of the TRacking Array for light Charged Ejectiles (TRACE). The ASICS were mounted on a custom-designed PCB (Printed Circuit Board) and the detector plugged on it. Energy resolution tests, performed on the same detector before and after irradiation, yielded a resolution of 21 keV and 33 keV FWHM respectively. The output signals were acquired with an array of commercial 100-MHz 14-bit digitizers. The preamplifier chip is equipped with an innovative Fast-Reset device that has two functions: it reduces dramatically the dead time of the preamplifier in case of saturation (from milliseconds to microseconds) and extends the spectroscopic dynamic range of the preamplifier by more than one order of magnitude. Other key points of the device are the low noise and the wide bandwidth.
|