Reig, M. (2019). On the high-scale instanton interference effect: axion models without domain wall problem. J. High Energy Phys., 08(8), 167–13pp.
Abstract: We show that a new chiral, confining interaction can be used to break Peccei-Quinn symmetry dynamically and solve the domain wall problem, simultaneously. The resulting theory is an invisible QCD axion model without domain walls. No dangerous heavy relics appear.
|
Bandyopadhyay, P., Chun, E. J., & Mandal, R. (2019). Phenomenology of Higgs bosons in inverse seesaw model with Type-X two Higgs doublet at the LHC. J. High Energy Phys., 08(8), 169–22pp.
Abstract: Type-X two Higgs doublet model is known to explain the muon g – 2 anomaly with a relatively light charged Higgs boson at large tan beta. The light charged Higgs boson has been searched in the main tau nu mode at the colliders. Invoking a scenario of inverse seesaw as the origin of neutrino masses and mixing, the charged Higgs boson can decay additionally to right-handed neutrinos which leads to interesting phenomenology. Considering generic lepton flavour violating signatures at the final states, a 5 sigma discovery can be achieved with the early data of LHC, at 14 TeV, for relatively large inverse seesaw Yukawa coupling Y-N. The very light pseudoscalar and charged Higgs boson mass reconstruction are performed using the new modes and the results look promising. The inverse seesaw Yukawa coupling is shown to be probed down to Y-N similar to 0.2 at HL LHC with 3000 fb(-1).
|
Vicente, A. (2019). Higgs Lepton Flavor Violating Decays in Two Higgs Doublet Models. Front. Physics, 7, 174–13pp.
Abstract: The discovery of a non-zero rate for a lepton flavor violating decay mode of the Higgs boson would definitely be an indication of New Physics. We review the prospects for such signal in Two Higgs Doublet Models, in particular for Higgs boson decays into tau μfinal states. We will show that this scenario contains all the necessary ingredients to provide large flavor violating rates and still be compatible with the stringent limits from direct searches and low-energy flavor experiments.
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Martinez-Vidal, F., Oyanguren, A., Remon Alepuz, C., et al. (2019). Measurement of the branching fractions of the decays D+ -> K-K+K+, D+ -> pi-pi(+) K+ and D-s(+) -> pi-K+K+. J. High Energy Phys., 03(3), 176–24pp.
Abstract: The branching fractions of the doubly Cabibbo-suppressed decays D+ ! K, D+ ! and D+ s ! are measured using the decays D+ ! K and D+ s ! K as normalisation channels. The measurements are performed using proton-proton collision data collected with the LHCb detector at a centre-of-mass energy of 8TeV, corresponding to an integrated luminosity of 2.0 fb. The results are B (D+ ! K) B (D+ ! K) = (6 : 541 0 : 025 0 : 042) 10 B (D+ ! ) B (D+ ! K) = (5 : 231 0 : 009 0 : 023) 10 B (D+ s ! ) B (D+ s ! K) = (2 : 372 0 : 024 0 : 025) 10 where the uncertainties are statistical and systematic, respectively. These are the most precise measurements up to date.
|
Capra, S., Mengoni, D., Dueñas, J. A., John, P. R., Gadea, A., Aliaga, R. J., et al. (2019). Performance of the new integrated front-end electronics of the TRACE array commissioned with an early silicon detector prototype. Nucl. Instrum. Methods Phys. Res. A, 935, 178–184.
Abstract: The spectroscopic performances of the new integrated ASIC (Application-Specific Integrated Circuit) preamplifiers for highly segmented silicon detectors have been evaluated with an early silicon detector prototype of the TRacking Array for light Charged Ejectiles (TRACE). The ASICS were mounted on a custom-designed PCB (Printed Circuit Board) and the detector plugged on it. Energy resolution tests, performed on the same detector before and after irradiation, yielded a resolution of 21 keV and 33 keV FWHM respectively. The output signals were acquired with an array of commercial 100-MHz 14-bit digitizers. The preamplifier chip is equipped with an innovative Fast-Reset device that has two functions: it reduces dramatically the dead time of the preamplifier in case of saturation (from milliseconds to microseconds) and extends the spectroscopic dynamic range of the preamplifier by more than one order of magnitude. Other key points of the device are the low noise and the wide bandwidth.
|