|
Modamio, V., Valiente-Dobon, J. J., Jaworski, G., Huyuk, T., Triossi, A., Egea, J., et al. (2015). Digital pulse-timing technique for the neutron detector array NEDA. Nucl. Instrum. Methods Phys. Res. A, 775, 71–76.
Abstract: A new digital pulse-timing algorithm, to be used with the future neutron detector array NEDA, has been developed and tested. The time resolution of four 5 in diameter photomultiplier tubes (XP4512, R4144, R11833-100, and ET9390-kb), coupled to a cylindrical 5 in by 5 in BC501A liquict scintillator detector was measured by employing digital sampling electronics and a constant fraction discriminator (CFD) algorithm. The zero crossing of the CM algorithm was obtained with a cubic spline interpolation, which was continuous up to the second derivative. The performance of the algorithm was studied at sampling rates of 500 MS/s and 200 MS/s. The time resolution obtained with the digital electronics was compared to the values acquired with a standard analog CFD. The result of this comparison shows that the time resolution from the analog and the digital measurements at 500 MS/s and at 200 MS/s are within 15% for all the tested photomultiplier tubes.
|
|
|
Doncel, M., Gadea, A., Valiente-Dobon, J. J., Quintana, B., Modamio, V., Mengoni, D., et al. (2017). Determination of lifetimes of nuclear excited states using the Recoil Distance Doppler Shift Method in combination with magnetic spectrometers. Eur. Phys. J. A, 53(10), 211–5pp.
Abstract: The current work presents the determination of lifetimes of nuclear excited states using the Recoil Distance Doppler Shift Method, in combination with spectrometers for ion identification, normalizing the intensity of the peaks by the ions detected in the spectrometer as a valid technique that produces results comparable to the ones obtained by the conventional shifted-to-unsifted peak ratio method. The technique has been validated using data measured with the gamma-ray array AGATA, the PRISMA spectrometer and the Cologne plunger setup. In this paper a test performed with the AGATA-PRISMA setup at LNL and the advantages of this new approach with respect to the conventional Recoil Distance Doppler Shift Method are discussed.
|
|
|
AGATA Collaboration(Modamio, V. et al), Gadea, A., Algora, A., & Huyuk, T. (2013). Lifetime measurements in neutron-rich Co-63,Co-65 isotopes using the AGATA demonstrator. Phys. Rev. C, 88(4), 044326–6pp.
Abstract: Lifetimes of the low-lying (11/2(-)) states in Co-63,Co-65 have been measured employing the recoil distance doppler shift method (RDDS) with the AGATA gamma-ray array and the PRISMA mass spectrometer. These nuclei were populated via a multinucleon transfer reaction by bombarding a U-238 target with a beam of Ni-64. The experimental B(E2) reduced transition probabilities for Co-63,Co-65 are well reproduced by large-scale shell-model calculations that predict a constant trend of the B(E2) values up to the N = 40 Co-67 isotope.
|
|
|
Modamio, V., Jungclaus, A., Algora, A., Bazzacco, D., Escrig, D., Fraile, L. M., et al. (2010). New high-spin isomer and quasiparticle-vibration coupling in Ir-187. Phys. Rev. C, 81(5), 054304–13pp.
Abstract: The high-spin structure of the Z = 77 nucleus Ir-187 has been studied using the fusion-evaporation reaction W-186(Li-7, (6)n) at a beam energy of 59 MeV. The excitation scheme of this nucleus has been extended by more than 110 new states, including extensions of all previously established rotational bands. The band crossing region of the h(9/2) negative-parity yrast band has been revised and new intrinsic high-K states have been identified. In particular, a 29/2(-) isomeric state [T-1/2 = 1.8(5)mu s] at an excitation energy of 2487 keV has been observed for the first time, and on top of it, a rich level scheme reaching up to spin (59/2(-)) and excitation energies around 7 MeV has been established.
|
|