Goasduff, A. et al, & Gadea, A. (2021). The GALILEO gamma-ray array at the Legnaro National Laboratories. Nucl. Instrum. Methods Phys. Res. A, 1015, 165753–15pp.
Abstract: GALILEO, a new 4 pi high-resolution gamma-detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital readout chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy gamma-ray transitions. In this work, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.
|
Fernandez, A. et al, Gadea, A., Perez-Vidal, R. M., Jurado, M., & Domingo-Pardo, C. (2021). Reinterpretation of excited states in Po-212: Shell-model multiplets rather than alpha-cluster states. Phys. Rev. C, 104(5), 054316–19pp.
Abstract: A gamma-ray spectroscopic study of Po-212 was performed at the Grand Accelerateur National d'Ions Lourds, using the inverse kinematics alpha-transfer reaction C-12(Pb-208, Po-212) Be-8 and the AGATA spectrometer. A careful analysis based on gamma gamma coincidence relations allowed us to establish 14 new excited states in the energy range between 1.9 and 3.3 MeV. None of these states, however, can be considered as candidates for the levels with spins and parities of 1(-) and 2(-) and excitation energies below 2.1 MeV, which have been predicted by recent alpha-cluster model calculations. A systematic comparison of the experimentally established excitation scheme of Po-212 with shell-model calculations was performed. This comparison suggests that the six states with excitation energies (spins and parities) of 1744 (4(-)), 1751 (8(-)), 1787 (6(-)), 1946 (4(-)), 1986 (8(-)), and 2016 (6(-)) keV, which previously were interpreted as alpha-cluster states, may in fact be of positive parity and belong to low-lying shell-model multiplets. This reinterpretation of the structure of Po-212 is supported by experimental information with respect to the linear polarization of gamma rays, which suggests a magnetic character of the 432-keV gamma ray decaying from the state at an excitation energy of 1787 keV to the 6(1)(+) yrast state, and exclusive reaction cross sections.
|
Tonev, D. et al, & Gadea, A. (2021). Transition probabilities in P-31 and S-31: A test for isospin symmetry. Phys. Lett. B, 821, 136603–6pp.
Abstract: Excited states in the mirror nuclei P-31 and S-31 were populated in the 1p and 1n exit channels of the reaction Ne-20 + C-12, at a beam energy of 33 MeV. The Ne-20 beam was delivered for the first time by the Piave-Alpi accelerator of the Laboratori Nazionali di Legnaro. Angular correlations of coincident gamma-rays and Doppler-shift attenuation lifetime measurements were performed using the multi-detector array GASP in conjunction with the EUCLIDES charged particle detector. In the observed B(E1) strengths, the isoscalar component, amounting to 24% of the isovector one, provides strong evidence for breaking of the isospin symmetry in the A = 31 mass region. Self-consistent beyond mean field calculations using Equation of Motion method based on a chiral potential and including two- and three-body forces reproduce well the experimental B(E1) strengths, reinforcing our conclusion. Coherent mixing from higher-lying states involving the Giant Isovector Monopole Resonance accounts well for the effect observed. The breaking of the isospin symmetry originates from the violation of the charge symmetry of the two- and three-body parts of the potential, only related to the Coulomb interaction.
|
Bertoldo, S., Maggioni, G., Raniero, W., Carraro, C., Riccetto, S., Sgarbossa, F., et al. (2021). New method for the production of thin and stable, segmented n plus contacts in HPGe detectors. Eur. Phys. J. A, 57(6), 177–10pp.
Abstract: The realization of pulsed-laser diffused, thin n+ contacts on high purity germanium (HPGe) and their successful segmentation is described. The contacts have been obtained by a laser-induced diffusion of Sb atoms, deposited by sputtering on Ge surface, and then segmented by means of a photolithographic technique. Three small prototypes of gamma ray detectors have been implemented, using the same n+ contact (laser diffused Sb) but with three different geometries and a B implanted p+ contact. Electrical and detection properties of the prototypes have been characterized, showing low leakage currents and good spectroscopy data with different gamma-ray sources. The stability of the detector performance has also been tested subjecting one of the prototypes to a typical annealing treatment.
|
Capra, S. et al, & Gadea, A. (2022). GALTRACE: A highly segmented silicon detector array for charged particle spectroscopy and discrimination. Nuovo Cim. C, 45(5), 98–4pp.
Abstract: GALTRACE is an array of segmented silicon detectors specifically built to work as an ancillary of the GALILEO gamma-ray spectrometer at Legnaro National Laboratory of INFN. GALTRACE consists of four telescopic Delta E-Edetectors which allow discriminating light charged particles also via pulse-shape analysis techniques. The good angular and energy resolutions, together with particle discrimination capabilities, make GALTRACE suitable for experiments where coincidences with specific emitted particles allow for the selection of reaction channels with very low cross section. The first in-beam experiment is reported here, aiming at identifying a narrow resonance, near-proton-threshold state in B-11, currently under discussion.
|