|   | 
Details
   web
Records
Author Kiesewetter, S.; Vento, V.
Title eta-eta '-glueball mixing Type Journal Article
Year 2010 Publication Physical Review D Abbreviated Journal Phys. Rev. D
Volume 82 Issue 3 Pages 034003 - 13pp
Keywords
Abstract We have revisited glueball mixing with the pseudoscalar mesons in the MIT bag model scheme. The calculation has been performed in the spherical cavity approximation to the bag using two different fermion propagators, the cavity and the free propagators. We obtain probabilities of mixing for the eta at the level of 0.006%-2.0%, while for the eta' one at the level of 0.6%-40%, depending on the choice of bag radius and, therefore, of the strong coupling constant. Our results differ from previous calculations. The origin of our difference stems from the treatment of the time integrations. The comparison of our calculation with experimental data, which is consistent with small eta – eta' – G mixing, implies that the pseudoscalar glueball is small, R similar to 0.5-0.6 fm and has a large mass, M-G similar to 2000-2500 MeV.
Address [Kiesewetter, Simon] Univ Valencia, Dept Fis Teor, CSIC, E-46100 Burjassot, Valencia, Spain
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1550-7998 ISBN Medium
Area Expedition Conference
Notes ISI:000280611800007 Approved no
Is ISI yes International Collaboration no
Call Number (down) IFIC @ elepoucu @ Serial 399
Permanent link to this record
 

 
Author Pierre Auger Collaboration (Abraham, J. et al); Pastor, S.
Title The fluorescence detector of the Pierre Auger Observatory Type Journal Article
Year 2010 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal Nucl. Instrum. Methods Phys. Res. A
Volume 620 Issue 2-3 Pages 227-251
Keywords Cosmic rays; Fluorescence detector
Abstract The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions.
Address [Bohacova, M.; Chudoba, J.; Grygar, J.; Hrabovsky, M.; Karova, T.; Mandat, D.; Necesal, P.; Nozka, L.; Nyklicek, M.; Palatka, M.; Pech, M.; Prouza, M.; Ridky, J.; Schovancova, J.; Schovanek, P.; Travnicek, P.] Acad Sci Czech Republic, Inst Phys, Prague, Czech Republic, Email: prouza@fzu.cz
Corporate Author Thesis
Publisher Elsevier Science Bv Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0168-9002 ISBN Medium
Area Expedition Conference
Notes ISI:000280601700018 Approved no
Is ISI yes International Collaboration yes
Call Number (down) IFIC @ elepoucu @ Serial 400
Permanent link to this record
 

 
Author Amaldi, U.; Bonomi, R.; Braccini, S.; Crescenti, M.; Degiovanni, A.; Garlasche, M.; Garonna, A.; Magrin, G.; Mellace, C.; Pearce, P.; Pitta, G.; Puggioni, P.; Rosso, E.; Verdu-Andres, S.; Wegner, R.; Weiss, M.; Zennaro, R.
Title Accelerators for hadrontherapy: From Lawrence cyclotrons to linacs Type Journal Article
Year 2010 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal Nucl. Instrum. Methods Phys. Res. A
Volume 620 Issue 2-3 Pages 563-577
Keywords Medical accelerators; Linac; Cyclotron; Synchrotron; Cyclinac; Radiation oncology; Hadrontherapy; Particle therapy; Proton therapy; Carbon ion therapy; Dose delivery
Abstract Hadrontherapy with protons and carbon ions is a fast developing methodology in radiation oncology. The accelerators used and planned for this purpose are reviewed starting from the cyclotrons used in the thirties. As discussed in the first part of this paper, normal and superconducting cyclotrons are still employed, together with synchrotrons, for proton therapy while for carbon ion therapy synchrotrons have been till now the only option. The latest developments concern a superconducting cyclotron for carbon ion therapy, fast-cycling high frequency linacs and 'single room' proton therapy facilities. These issues are discussed in the second part of the paper by underlining the present challenges, in particular the treatment of moving organs.
Address [Amaldi, U.; Bonomi, R.; Braccini, S.; Crescenti, M.; Degiovanni, A.; Garlasche, M.; Garonna, A.; Magrin, G.; Mellace, C.; Pearce, P.; Pitta, G.; Puggioni, P.; Rosso, E.; Andres, S. Verdu; Wegner, R.; Weiss, M.; Zennaro, R.] TERA Fdn, Novara, Italy, Email: Saverio.Braccini@cern.ch
Corporate Author Thesis
Publisher Elsevier Science Bv Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0168-9002 ISBN Medium
Area Expedition Conference
Notes ISI:000280601700058 Approved no
Is ISI yes International Collaboration yes
Call Number (down) IFIC @ elepoucu @ Serial 401
Permanent link to this record
 

 
Author BABAR Collaboration (Aubert, B. et al); Azzolini, V.; Lopez-March, N.; Martinez-Vidal, F.; Milanes, D.A.; Oyanguren, A.
Title Measurements of Charged Current Lepton Universality and vertical bar V-us vertical bar Using Tau Lepton Decays to e(-)(nu)over-bar(e)nu(tau), mu(-)(nu)over-bar(mu)nu(tau), pi(-)nu(tau), and K-nu(tau) Type Journal Article
Year 2010 Publication Physical Review Letters Abbreviated Journal Phys. Rev. Lett.
Volume 105 Issue 5 Pages 051602 - 8pp
Keywords
Abstract Using 467 fb(-1) of e(+)e(-) annihilation data collected with the BABAR detector, we measure B(tau(-)->mu(-)(nu) over bar (mu)nu(tau))/B(tau(-)-> e(-)(nu) over bar (e)nu(tau)) = (0.9796 +/- 0.0016 +/- 0.0036), B(tau(-)->pi(-)nu(tau))/B(tau(-)-> e(-)nu(e)nu(tau)) = (0.5945 +/- 0.0014 +/- 0.0061), and B(tau(-)-> K-nu(tau))/B(tau(-)-> e(-)nu(e)nu(tau)) = (0.03882 +/- 0.00032 +/- 0.00057), where the uncertainties are statistical and systematic, respectively. From these precision similar to measurements, we test the standard model assumption of μ- e and tau – μcharge current lepton universality and provide determinations of vertical bar V-us vertical bar experimentally independent of the decay of a kaon.
Address [Aubert, B.; Karyotakis, Y.; Lees, J. P.; Poireau, V.; Prencipe, E.; Prudent, X.; Tisserand, V.] Univ Savoie, Lab Annecy le Vieux Phys Particules, CNRS, IN2P3, F-74941 Annecy Le Vieux, France
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0031-9007 ISBN Medium
Area Expedition Conference
Notes ISI:000280472700002 Approved no
Is ISI yes International Collaboration yes
Call Number (down) IFIC @ elepoucu @ Serial 402
Permanent link to this record
 

 
Author Gonzalez-Alonso, M.; Pich, A.; Prades, J.
Title Pinched weights and duality violation in QCD sum rules: A critical analysis Type Journal Article
Year 2010 Publication Physical Review D Abbreviated Journal Phys. Rev. D
Volume 82 Issue 1 Pages 014019 - 7pp
Keywords
Abstract We analyze the so-called pinched weights, that are generally thought to reduce the violation of quarkhadron duality in finite-energy sum rules. After showing how this is not true in general, we explain how to address this question for the left-right correlator and any particular pinched weight, taking advantage of our previous work [1], where the possible high-energy behavior of the left-right spectral function was studied. In particular, we show that the use of pinched weights allows to determine with high accuracy the dimension six and eight contributions in the operator-product expansion, O-6 = (-4.3(-0.7)(+0.9)) x 10(-3) GeV6 and O-8 = (-7.2(-5.3)(+4.2)) x 10(-3) GeV8.
Address [Gonzalez-Alonso, Martin; Pich, Antonio] Univ Valencia, CSIC, Dept Fis Teor, E-46071 Valencia, Spain
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1550-7998 ISBN Medium
Area Expedition Conference
Notes ISI:000280470200001 Approved no
Is ISI yes International Collaboration no
Call Number (down) IFIC @ elepoucu @ Serial 403
Permanent link to this record