Details
   web
Records
Author de Souza, P.M.; Muller, A.; Beniaich, A.; Mayer-Miebach, E.; Oehlke, K.; Stahl, M.; Greiner, R.; Fernandez, A.
Title Functional properties and nutritional composition of liquid egg products treated in a coiled tube UV-C reactor Type Journal Article
Year 2015 Publication Innovative Food Science & Emerging Technologies Abbreviated Journal Innov. Food Sci. Emerg. Technol.
Volume 32 Issue Pages 156-164
Keywords Ultraviolet; Liquid egg; Vitamins; Functional properties; Foaming; UV-C; Dean vortex
Abstract Pasteurization of eggs has adverse effects on nutrient composition and functionality of egg proteins. UV processing is an alternative technology with potentially fewer adverse effects as it is less intrusive. Egg white, whole egg and egg yolk vitamins (A, B-2, B-5, C and E), minerals (P, Cl, K, Na, Ca, Mg, Fe and Zn) and main secondary metabolites (lutein and zeaxanthin) were examined after exposure to UV in a coiled tube UV-C reactor at doses known to achieve microbiologically stable egg fractions. The studied nutrients were fairly stable to a treatment with UVC light with the exception of retinal, vitamin C and carotenoids, which showed loses up to 80%, 66% and 61%, respectively. Moreover, the functional properties of ultraviolet-treated eggs were investigated. Results showed a positive impact on the foam ability and foam stability, and an increase on the emulsifying activity index above 20% versus pasteurized samples. Processing with UV can maintain most of the egg nutritive properties, and retain or even improve the technological properties of foaming and emulsification in eggs. Industrial relevance:: This novel UV-C system can be applied successfully to the Food Industry. UV-C does not impair nutritional damage to egg-treated products, and even improve egg functional properties.
Address [Mendes de Souza, Poliana; Fernandez, Avelina] Inst Agroquim & Tecnol Alimentos, CSIC, Dept Conservat & Qual, Paterna 46980, Spain, Email: poliana.souza@ict.ufvjm.edu.br
Corporate Author Thesis
Publisher Elsevier Sci Ltd Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1466-8564 ISBN Medium
Area Expedition Conference
Notes WOS:000366764200019 Approved no
Is ISI yes International Collaboration yes
Call Number (down) IFIC @ pastor @ Serial 2506
Permanent link to this record
 

 
Author Lloret, E.; Picouet, P.A.; Trbojevich, R.; Fernandez, A.
Title Colour stability of cooked ham packed under modified atmospheres in polyamide nanocomposite blends Type Journal Article
Year 2016 Publication Lwt-Food Science And Technology Abbreviated Journal LWT-Food Sci. Technol.
Volume 66 Issue Pages 582-589
Keywords Nylon; Cooked ham; Nanoclays; Oxygen permeation; Colour; Exfoliation; MAP
Abstract Two novel blends containing a low-density polyethylene (LDPE) and a neat polyamide (PA) or a polyamide nanocomposite (PAN) layers were fabricated and their technological potential was evaluated during the refrigeration of cooked ham in modified atmospheres (MAP). Nanoclays were homogeneously distributed and nearly exfoliated, and they lowered significantly the oxygen transmission rate (OTR) of the PAN films. Due to the lower OTR, the headspace oxygen level in PAN pouches do not rise above 0.26% but it approached 2% in PA pouches at day 20. The residual oxygen levels were key for colour change during MAP storage of cooked ham. Cooked ham redness and reflectivity were stable during 27 days in PAN pouches while a strong colour deterioration took place after day 7 in PA pouches. Other parameters such as moisture content and water activity remained unaltered, and pH development was related to microbial growth and independent of the packaging polymer. The evolution of cooked ham colour in PAN was comparable to a high-barrier commercial polymer, and was acceptable for commercial sale for 27 days, showing excellent perspectives for polyamide nanocomposites in the storage of cooked ham.
Address [Lloret, Elsa; Picouet, Pierre A.] IRTA, Dept Tecnol Dels Aliments, Monells, Girona, Spain, Email: velifdez@ific.uv.es
Corporate Author Thesis
Publisher Elsevier Science Bv Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0023-6438 ISBN Medium
Area Expedition Conference
Notes WOS:000367413200079 Approved no
Is ISI yes International Collaboration yes
Call Number (down) IFIC @ pastor @ Serial 2510
Permanent link to this record
 

 
Author Chen, P.; Ding, G.J.; Rojas, A.D.; Vaquera-Araujo, C.A.; Valle, J.W.F.
Title Warped flavor symmetry predictions for neutrino physics Type Journal Article
Year 2016 Publication Journal of High Energy Physics Abbreviated Journal J. High Energy Phys.
Volume 01 Issue 1 Pages 007 - 27pp
Keywords Quark Masses and SM Parameters; Neutrino Physics; Discrete and Finite Symmetries
Abstract A realistic five-dimensional warped scenario with all standard model fields propagating in the bulk is proposed. Mass hierarchies would in principle be accounted for by judicious choices of the bulk mass parameters, while fermion mixing angles are restricted by a Delta(27) flavor symmetry broken on the branes by flavon fields.The latter gives stringent predictions for the neutrino mixing parameters, and the Dirac CP violation phase, all described in terms of only two independent parameters at leading order. The scheme also gives an adequate CKM fit and should be testable within upcoming oscillation experiments.
Address [Chen, Peng; Ding, Gui-Jun] Univ Sci & Technol China, Dept Modern Phys, Hefei 230026, Anhui, Peoples R China, Email: pche@mail.ustc.edu.cn;
Corporate Author Thesis
Publisher Springer Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1029-8479 ISBN Medium
Area Expedition Conference
Notes WOS:000367831200001 Approved no
Is ISI yes International Collaboration yes
Call Number (down) IFIC @ pastor @ Serial 2518
Permanent link to this record
 

 
Author Candela-Juan, C.; Ballester, F.; Perez-Calatayud, J.; Vijande, J.
Title Assaying multiple I-125 seeds with the well-ionization chamber SourceCheck(4 Pi) 33005 and a new insert Type Journal Article
Year 2015 Publication Journal of Contemporary Brachytherapy Abbreviated Journal J. Contemp. Brachytherapy
Volume 7 Issue 6 Pages 492-496
Keywords brachytherapy; insert; quality assurance; prostate; seeds; well chamber
Abstract Purpose: To provide a practical solution that can be adopted in clinical routine to fulfill the AAPM-ESTRO recommendations regarding quality assurance of seeds used in prostate permanent brachytherapy. The aim is to design a new insert for the well-ionization chamber SourceCheck(4 Pi) 33005 (PTW, Germany) that allows evaluating the mean air-kerma strength of up to ten I-125 seeds with one single measurement instead of measuring each seed individually. Material and methods: The material required is: a) the SourceCheck(4 Pi) 33005 well-ionization chamber provided with a PTW insert to measure the air-kerma strength S-K of one single seed at a time; b) a newly designed insert that accommodates ten seeds in one column, which allows measuring the mean S-K of the ten seeds in one single measurement; and c) a container with ten seeds from the same batch and class of the seeds used for the patient implant, and a set of nine non-radioactive seeds.The new insert is characterized by determining its calibration coefficient, used to convert the reading of the well-chamber when ten seeds are measured to their mean S-K. The proposed method is validated by comparing the mean S-K of the ten seeds obtained from the new insert with the individual measurement of S-K of each seed, evaluated with the PTW insert. Results: The ratio between the calibration coefficient of the new insert and the calibration coefficient of the PTW insert for the SourceCheck(4 Pi) 33005 is 1.135 +/- 0.007 (k = 1). The mean S-K of a set of ten seeds evaluated with this new system is in agreement with the mean value obtained from measuring independently the S-K of each seed. Conclusions: The new insert and procedure allow evaluating the mean S-K of ten seeds prior to the implant in a single measurement. The method is faster and more efficient from radiation protection point of view than measuring the individual S-K of each seed.
Address [Candela-Juan, Cristian; Perez-Calatayud, Jose] La Fe Univ, Dept Radiat Oncol, Phys Sect, E-46026 Valencia, Spain, Email: ccanjuan@gmail.com
Corporate Author Thesis
Publisher Termedia Publishing House Ltd Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1689-832x ISBN Medium
Area Expedition Conference
Notes WOS:000368381300010 Approved no
Is ISI yes International Collaboration no
Call Number (down) IFIC @ pastor @ Serial 2533
Permanent link to this record
 

 
Author Barrio, J.; Etxebeste, A.; Lacasta, C.; Muñoz, E.; Oliver, J.F.; Solaz, C.; Llosa, G.
Title Performance of VATA64HDR16 ASIC for medical physics applications based on continuous crystals and SiPMs Type Journal Article
Year 2015 Publication Journal of Instrumentation Abbreviated Journal J. Instrum.
Volume 10 Issue Pages P12001 - 12pp
Keywords Solid state detectors; Photon detectors for UV, visible and IR photons (solid-state) (PIN diodes, APDs, Si-PMTs, G-APDs, CCDs, EBCCDs, EMCCDs etc); Front-end electronics for detector readout; Gamma detectors (scintillators, CZT, HPG, HgI etc)
Abstract Detectors based on Silicon Photomultipliers (SiPMs) coupled to continuous crystals are being tested in medical physics applications due to their potential high resolution and sensitivity. To cope with the high granularity required for a very good spatial resolution, SiPM matrices with a large amount of elements are needed. To be able to read the information coming from each individual channel, dedicated ASICs are employed. The VATA64HDR16 ASIC is a 64-channel, charge-sensitive amplifier that converts the collected charge into a proportional current or voltage signal. A complete assessment of the suitability of that ASIC for medical physics applications based on continuous crystals and SiPMs has been carried out. The input charge range is linear from 20 pC up to 55 pC. The energy resolution obtained at 511 keV is 10% FWHM with a LaBr3 crystal and 16% FWHM with a LYSO crystal. A coincidence timing resolution of 24 ns FWHM is obtained with two LYSO crystals.
Address [Barrio, J.; Etxebeste, A.; Lacasta, C.; Munoz, E.; Oliver, J. F.; Solaz, C.; Llosa, G.] Univ Valencia, CSIC, Inst Fis Corpuscular, Parque Cient,C Catedrat Jose Beltran 2, E-46980 Paterna, Spain, Email: John.Barrio@ific.uv.es
Corporate Author Thesis
Publisher Iop Publishing Ltd Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1748-0221 ISBN Medium
Area Expedition Conference
Notes WOS:000369998500034 Approved no
Is ISI yes International Collaboration no
Call Number (down) IFIC @ pastor @ Serial 2548
Permanent link to this record