|   | 
Details
   web
Records
Author Scandale, W et al; Lari, L.
Title Deflection of high energy protons by multiple volume reflections in a modified multi-strip silicon deflector Type Journal Article
Year 2014 Publication Nuclear Instruments & Methods in Physics Research B Abbreviated Journal Nucl. Instrum. Methods Phys. Res. B
Volume 338 Issue Pages 108-111
Keywords Accelerator; Beam collimation; Crystal; Channeling; Volume reflection
Abstract The effect of multiple volume reflections in one crystal was observed in each of several bent silicon strips for 400 GeV/c protons. This considerably increased the particle deflections. Some particles were also deflected due to channeling in one of the subsequent strips. As a result, the incident beam was strongly spread because of opposite directions of the deflections. A modified multi-strip deflector produced by periodic grooves on the surface of a thick silicon plate was used for these measurements. This technique provides perfect mutual alignment between crystal strips. Such multi-strip deflector may be effective for collider beam halo collimation and a study is planned at the CERN SPS circulating beam.
Address [Scandale, W.; Arduini, G.; Butcher, M.; Cerutti, F.; Gilardoni, S.; Lari, L.; Lechner, A.; Losito, R.; Masi, A.; Mereghetti, A.; Metral, E.; Mirarchi, D.; Montesano, S.; Redaelli, S.; Schoofs, P.; Smirnov, G.] CERN, European Org Nucl Res, CH-1211 Geneva 23, Switzerland
Corporate Author Thesis
Publisher Elsevier Science Bv Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0168-583x ISBN Medium
Area Expedition Conference
Notes WOS:000343390400016 Approved no
Is ISI yes International Collaboration yes
Call Number (up) IFIC @ pastor @ Serial 1974
Permanent link to this record
 

 
Author LHCb Collaboration (Aaij, R. et al); Martinez-Vidal, F.; Oyanguren, A.; Ruiz Valls, P.; Sanchez Mayordomo, C.
Title Measurement of the CKM angle gamma using B-+/- -> DK +/- with D -> K-S(0)pi(+)pi(-), (KSK+K-)-K-0 decays Type Journal Article
Year 2014 Publication Journal of High Energy Physics Abbreviated Journal J. High Energy Phys.
Volume 10 Issue 10 Pages 097 - 52pp
Keywords CP violation; CKM angle gamma; Hadron-Hadron Scattering; B physics; Flavor physics
Abstract A binned Dalitz plot analysis of B-+/- -> DK +/- decays, with D -> K-S(0) pi(+)pi(-) and D -> K0 S K + K -, is performed to measure the C P -violating observables x(+/-) and y(+/-), which are sensitive to the Cabibbo-Kobayashi-Maskawa angle gamma. The analysis exploits a sample of proton-proton collision data corresponding to 3.0 fb(-1) collected by the LHCb experiment. Measurements from CLEO-c of the variation of the strong-interaction phase of the D decay over the Dalitz plot are used as inputs. The values of the parameters are found to be x(+) = (-7.7 +/- 2.4 +/- 1.0 +/- 0.4) x 10(-2), x(-) = (2.5 +/- 2.5 +/- 1.0 +/- 0.5) x 10(-2), y(+) = (-2.2 +/- 2.5 +/- 0.4 +/- 1.0) x 10-2, and y(-) = (7.5 +/- 2.9 +/- 0.5 +/- 1.4) x 10(-2). The first, second, and third uncertainties are the statistical, the experimental systematic, and that associated with the precision of the strong-phase parameters. These are the most precise measurements of these observables and correspond to +/- = (62(-14)(+15))degrees, with a second solution at gamma -> gamma + 180 degrees, and r(B) = 0.080(-0.021)(+0.019), where r(B) is the ratio between the suppressed and favoured B decay amplitudes.
Address [Bediaga, I.; De Miranda, J. M.; Ferreira Rodrigues, F.; Gomes, A.; Hicheur, A.; Massafferri, A.; dos Reis, A. C.; Rodrigues, A. B.] Ctr Brasileiro Pesquisas Fis, Rio De Janeiro, Brazil, Email: s.malde1@physics.ox.ac.uk
Corporate Author Thesis
Publisher Springer Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1029-8479 ISBN Medium
Area Expedition Conference
Notes WOS:000344077300001 Approved no
Is ISI yes International Collaboration yes
Call Number (up) IFIC @ pastor @ Serial 1981
Permanent link to this record
 

 
Author Ullan, M.; Benitez, V.; Quirion, D.; Zabala, M.; Pellegrini, G.; Lozano, M.; Lacasta, C.; Soldevila, U.; Garcia, C.; Fadeyev, V.; Wortman, J.; DeFilippis, J.; Shumko, M.; Grillo, A.A.; Sadrozinski, H.F.W.
Title Low-resistance strip sensors for beam-loss event protection Type Journal Article
Year 2014 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal Nucl. Instrum. Methods Phys. Res. A
Volume 765 Issue Pages 252-257
Keywords Silicon radiation detectors; Strip sensors; Punch through protection; Beam loss; HL-LHC; ATLAS Upgrade
Abstract AC coupled silicon strip sensors can be damaged in case of a beam loss due to the possibility of a large charge accumulation in the bulk, developing very high voltages across the coupling capacitors which can destroy them. Punch-through structures are currently used to avoid this problem helping to evacuate the accumulated charge as large voltages are developing. Nevertheless, previous experiments, performed with laser pulses, have shown that these structures can become ineffective in relatively long strips. The large value of the implant resistance can effectively isolate the “far” end of the strip from the punchthrough structure leading to large voltages. We present here our developments to fabricate lowresistance strip sensors to avoid this problem. The deposition of a conducting material in contact with the implants drastically reduces the strip resistance, assuring the effectiveness of the punch-through structures. First devices have been fabricated with this new technology. Initial results with laser tests show the expected reduction in peak voltages on the low resistivity implants. Other aspects of the sensor performance, including the signal formation, are not affected by the new technology.
Address [Ullan, M.; Benitez, V.; Quirion, D.; Zabala, M.; Pellegrini, G.; Lozano, M.] CSIC, Ctr Nacl Microelect IMB CNM, Barcelona 08193, Spain, Email: Miguel.Ullan@imb-cnm.csic.es
Corporate Author Thesis
Publisher Elsevier Science Bv Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0168-9002 ISBN Medium
Area Expedition Conference
Notes WOS:000344621000048 Approved no
Is ISI yes International Collaboration yes
Call Number (up) IFIC @ pastor @ Serial 2003
Permanent link to this record
 

 
Author Luo, X.L. et al; Agramunt, J.; Egea, F.J.; Gadea, A.; Huyuk, T.
Title Test of digital neutron-gamma discrimination with four different photomultiplier tubes for the NEutron Detector Array (NEDA) Type Journal Article
Year 2014 Publication Nuclear Instruments & Methods in Physics Research A Abbreviated Journal Nucl. Instrum. Methods Phys. Res. A
Volume 767 Issue Pages 83-91
Keywords Digital neutron-gamma discrimination; Liquid scintillator; Photomultiplier tube; Charge Comparison; Integrated rise-time; Time-of-flight; NEDA
Abstract A comparative study of the neutron-gamma discrimination performance of a liquid scintillator detector BC501A coupled to four different 5 in photomultiplier tubes (ET9390kb, R11833-100, XP4512 and R4144) was carried out Both the Charge Comparison method and the Integrated Rise-Time method were implemented digitally to discriminate between neutrons and gamma rays emitted by a Cf-252 source. In both methods, the neutron-gamma discrimination capabilities of the four photomultiplier tubes were quantitatively compared by evaluating their figure-of-merit values at different energy regions between 50 keVee and 1000 keVee. Additionally, the results were further verified qualitatively using time-of-flight to distinguish gamma rays and neutrons. The results consistently show that photomultiplier tubes R11833-100 and ET9390kb generally perform best regarding neutron-gamma discrimination with only slight differences in figure-of-merit values. This superiority can be explained by their relatively higher photoelectron yield, which indicates that a scintillator detector coupled to a photomultiplier tube with higher photoelectron yield tends to result in better neutron-gamma discrimination performance. The results of this work will provide reference for the choice of photomultiplier tubes for future neutron detector arrays like NEDA.
Address [Luo, X. L.] Natl Univ Def Technol, Coll Mechatron & Automat, Dept Instrument Sci & Technol, Changsha, Hunan, Peoples R China, Email: luo.xiaoliang@physics.uu.se
Corporate Author Thesis
Publisher Elsevier Science Bv Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0168-9002 ISBN Medium
Area Expedition Conference
Notes WOS:000344994600012 Approved no
Is ISI yes International Collaboration yes
Call Number (up) IFIC @ pastor @ Serial 2011
Permanent link to this record
 

 
Author LHCb Collaboration (Aaij, R. et al); Martinez-Vidal, F.; Oyanguren, A.; Ruiz Valls, P.; Sanchez Mayordomo, C.
Title Measurement of CP asymmetry in B-s(0) -> D-s(-/+) K-/+ decays Type Journal Article
Year 2014 Publication Journal of High Energy Physics Abbreviated Journal J. High Energy Phys.
Volume 11 Issue 11 Pages 060 - 30pp
Keywords CP violation; CKM angle gamma; B physics; Flavor physics; Hadron-Hadron Scattering
Abstract We report on measurements of the time-dependent CP violating observables in B-s(0) -> D-s(-/+) K--/+ decays using a dataset corresponding to 1.0 fb(-1) of pp collisions recorded with the LHCb detector. We find the CP violating observables C-f = 0.53 +/- 0.25 +/- 0.04, A(f)(Delta Gamma) = 0.37 +/- 0.42 +/- 0.20, A((f) over bar)(Delta Gamma) = 0.20 +/- 0.41 +/- 0.20, S-f = -1.09 +/- 0.33 +/- 0.08, S-(f) over bar = -0.36 +/- 0.34 +/- 0.08, where the uncertainties are statistical and systematic, respectively. Using these observables together with a recent measurement of the B-s(0) mixing phase -2 beta(s) leads to the first extraction of the CKM angle gamma from B-s(0) -> D-s(-/+) K--/+ decays, finding gamma = (115(-43)(+28))degrees modulo 180 degrees at 68% CL, where the error contains both statistical and systematic uncertainties.
Address [Bediaga, I.; De Miranda, J. M.; Rodrigues, F. Ferreira; Gomes, A.; Hicheur, A.; Massafferri, A.; dos Reis, A. C.; Rodrigues, A. B.] CBPF, Rio De Janeiro, Brazil
Corporate Author Thesis
Publisher Springer Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1029-8479 ISBN Medium
Area Expedition Conference
Notes WOS:000345080300001 Approved no
Is ISI yes International Collaboration yes
Call Number (up) IFIC @ pastor @ Serial 2012
Permanent link to this record