Llosa, G., Barrio, J., Lacasta, C., Bisogni, M. G., Del Guerra, A., Marcatili, S., et al. (2010). Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matrices. Phys. Med. Biol., 55(23), 7299–7315.
Abstract: The characterization of a PET detector head based on continuous LYSO crystals and silicon photomultiplier (SiPM) arrays as photodetectors has been carried out for its use in the development of a small animal PET prototype. The detector heads are composed of a continuous crystal and a SiPM matrix with 64 pixels in a common substrate, fabricated specifically for this project. Three crystals of 12 mm x 12 mm x 5 mm size with different types of painting have been tested: white, black and black on the sides but white on the back of the crystal. The best energy resolution, obtained with the white crystal, is 16% FWHM. The detector response is linear up to 1275 keV. Tests with different position determination algorithms have been carried out with the three crystals. The spatial resolution obtained with the center of gravity algorithm is around 0.9 mm FWHM for the three crystals. As expected, the use of this algorithm results in the displacement of the reconstructed position toward the center of the crystal, more pronounced in the case of the white crystal. A maximum likelihood algorithm has been tested that can reconstruct correctly the interaction position of the photons also in the case of the white crystal.
|
|
|
Agullo, I., Navarro-Salas, J., Olmo, G. J., & Parker, L. (2010). Hawking Radiation by Kerr Black Holes and Conformal Symmetry. Phys. Rev. Lett., 105(21), 211305–4pp.
Abstract: The exponential blueshift associated with the event horizon of a black hole makes conformal symmetry play a fundamental role in accounting for its thermal properties. Using a derivation based on two-point functions, we show that the full spectrum of thermal radiation of scalar particles by Kerr black holes can be explicitly derived on the basis of a conformal symmetry arising in the wave equation near the horizon. The simplicity of our approach emphasizes the depth of the connection between conformal symmetry and black hole radiance.
|
|
|
Yamagata-Sekihara, J., Roca, L., & Oset, E. (2010). Nature of the K-2*(1430), K-3*(1780), K-4*(2045), K-5*(2380), and K-6* as K*-multi-rho states. Phys. Rev. D, 82(9), 094017–8pp.
Abstract: We show that the K-2*(1430), K-3*(1780), K-4*(2045), K-5*(2380), and a not-yet-discovered K-6* resonance are basically molecules made of an increasing number of rho(770) and one K*(892) mesons. The idea relies on the fact that the vector-vector interaction in the s wave with spins aligned is very strong for both rho rho and K*rho. We extend a recent work, where several resonances showed up as multi-rho(770) molecules, to the strange sector including the K*(892) into the system. The resonant structures show up in the multibody scattering amplitudes, which are evaluated in terms of the unitary two-body vector-vector scattering amplitudes by using the fixed center approximation to the Faddeev equations.
|
|
|
BABAR Collaboration(del Amo Sanchez, P. et al), Lopez-March, N., Martinez-Vidal, F., Milanes, D. A., & Oyanguren, A. (2010). Exclusive production of Ds+Ds-,D-s*D-+(s)-, and D-s*D-+(s)*(-) via e(+)e(-) annihilation with initial-state radiation. Phys. Rev. D, 82(5), 052004–10pp.
Abstract: We perform a study of exclusive production of Ds+Ds-,D-s*(+),D-s(-), and D-s*D-+(s)*- final states in initial-state radiation events from e(+)e(-) annihilations at a center-of-mass energy near 10.58 GeV, to search for charmonium 1(--) states. The data sample corresponds to an integrated luminosity of 525 fb(-1) and was recorded by the BABAR experiment at the PEP-II storage ring. Ds+Ds-,D-s*(+),D-s(-) and ,D-s*(+),D-s*(-) mass spectra show evidence of the known psi resonances. Limits are extracted for the branching ratios of the decays X(4260) -> D-s(()*()+) D-s(()*()-)
|
|
|
HADES Collaboration(Agakishiev, G. et al), Diaz, J., & Gil, A. (2010). Lambda-p femtoscopy in collisions of Ar + KCl at 1.76AGeV. Phys. Rev. C, 82(2), 021901–5pp.
Abstract: Results on Lambda p femtoscopy are reported at the lowest energy so far. At a beam energy of 1.76AGeV, the reaction Ar + KCl was studied with the High Acceptance Di-Electron Spectrometer ( HADES) at SIS18/GSI. A high-statistics and high-purity Lambda sample was collected, allowing for the investigation of Lambda p correlations at low relative momenta. The experimental correlation function is compared to corresponding model calculations allowing the determination of the space-time extent of the Lambda p emission source. The Lambda p source radius is found to be slightly smaller than the pp correlation radius for a similar collision system. The present Lambda p radius is significantly smaller than that found for Au + Au/Pb + Pb collisions in the AGS, SPS, and RHIC energy domains but larger than that observed for electroproduction from He. Taking into account all available data, we find the Lambda p source radius to increase almost linearly with the number of participants to the power of one-third.
|
|