Miralles, V., Miralles Lopez, M., Moreno Llacer, M., Peñuelas, A., Perello, M., & Vos, M. (2022). The top quark electro-weak couplings after LHC Run 2. J. High Energy Phys., 02(2), 032–24pp.
Abstract: Recent measurements at the Large Hadron Collider allow for a robust and precise characterisation of the electro-weak interactions of the top quark. We present the results of a global analysis at next-to-leading order precision including LHC, LEP/SLD and Tevatron data in the framework of the Standard Model Effective Field Theory. We include a careful analysis of the impact of correlations among measurements, as well as of the uncertainties in the Effective Field Theory setup itself. We find remarkably robust global fit results, with central values in good agreement with the Standard Model prediction, and 95% probability bounds on Wilson coefficients that range from +/- 0.35 to +/- 8 TeV-2. This result represents a considerable improvement over previous studies, thanks to the addition of differential cross-section measurements in associated production processes of top quarks and neutral gauge bosons.
|
MiniBooNE Collaboration(Aguilar-Arevalo, A. A. et al), & Sorel, M. (2013). Test of Lorentz and CPT violation with short baseline neutrino oscillation excesses. Phys. Lett. B, 718(4-5), 1303–1308.
Abstract: The sidereal time dependence of MiniBooNE nu(e) and (nu) over bar (e) appearance data is analyzed to search for evidence of Lorentz and CPT violation. An unbinned Kolmogorov-Smirnov (K-S) test shows both the nu(e) and (nu) over bar (e) appearance data are compatible with the null sidereal variation hypothesis to more than 5%. Using an unbinned likelihood fit with a Lorentz-violating oscillation model derived from the Standard Model Extension (SME) to describe any excess events over background, we find that the nu(e) appearance data prefer a sidereal time-independent solution, and the (nu) over bar (e) appearance data slightly prefer a sidereal time-dependent solution. Limits of order 10(-20) GeV are placed on combinations of SME coefficients. These limits give the best limits on certain SME coefficients for nu(mu) -> nu(e) and (nu) over bar (mu) -> (nu) over bar (e) oscillations. The fit values and limits of combinations of SME coefficients are provided.
|
Minakata, H., & Pena-Garay, C. (2012). Solar Neutrino Observables Sensitive to Matter Effects. Adv. High. Energy Phys., 2012, 349686–15pp.
Abstract: We discuss constraints on the coefficient A(MSW) which is introduced to simulate the effect of weaker or stronger matter potential for electron neutrinos with the current and future solar neutrino data. The currently available solar neutrino data leads to a bound A(MSW) = 1.47(+0.54)(-0.42)((-0.82)(+1.88)) at 1 sigma (3 sigma) CL, which is consistent with the Standard Model prediction A(MSW) = 1. For weaker matter potential (A(MSW) < 1), the constraint which comes from the flat B-8 neutrino spectrum is already very tight, indicating the evidence for matter effects. However for stronger matter potential (A(MSW) > 1), the bound is milder and is dominated by the day-night asymmetry of B-8 neutrino flux recently observed by Super-Kamiokande. Among the list of observables of ongoing and future solar neutrino experiments, we find that (1) an improved precision of the day-night asymmetry of B-8 neutrinos, (2) precision measurements of the low-energy quasi-monoenergetic neutrinos, and (3) the detection of the upturn of the B-8 neutrino spectrum at low energies are the best choices to improve the bound on A(MSW).
|
Migueis, F., Casaña, J. V., Garcia-Fernandez, D., Hueso-Gonzalez, F., Llosa, G., Prieto, A. F., et al. (2025). Sensitivity of coaxial prompt gamma-ray monitoring in heterogeneous geometries: A Monte Carlo simulation study. Radiat. Phys. Chem., 232, 112639–11pp.
Abstract: Proton beams offer significant advantages over conventional radiotherapy due to their unique interaction with matter. Specifically, the ionization density caused by these beams is higher in a well-defined region (the Bragg peak) with a sharp decline in intensity beyond a specific depth. However, variations in proton range – often caused by changes in patient anatomy and morphology during treatment – can introduce uncertainties in dose distribution. To account for this, clinicians apply conservative margins, which limit the full potential of proton therapy. Efforts have been focused on developing proton range and dose distribution monitoring systems to reduce the need for large safety margins. These systems are based on detecting and analyzing the byproducts that result from the interaction between the proton beams and tissue. In this article, we focused specifically on a system that aims to detect photons called prompt gamma (PG) rays. We conducted Monte Carlo simulations of proton beams interacting with anthropomorphic phantoms of varying densities to simulate morphological changes. A single scintillation detector was positioned coaxially with the beam and behind the phantom to capture the emitted PG rays in each scenario. Our analysis focused on discrepancies in proton range that resulted from irradiating an anthropomorphic head phantom with varying brain tissue densities and detecting secondary particles resulting from these interactions. We observed potential correlations between gamma-ray signatures and variations in proton range and energy deposition, suggesting that this monitoring technique could be effective for real-world clinical applications.
|
Mertsch, P., Parimbelli, G., de Salas, P. F., Gariazzo, S., Lesgourgues, J., & Pastor, S. (2020). Neutrino clustering in the Milky Way and beyond. J. Cosmol. Astropart. Phys., 01(1), 015–23pp.
Abstract: The standard cosmological model predicts the existence of a Cosmic Neutrino Background, which has not yet been observed directly. Some experiments aiming at its detection are currently under development, despite the tiny kinetic energy of the cosmological relic neutrinos, which makes this task incredibly challenging. Since massive neutrinos are attracted by the gravitational potential of our Galaxy, they can cluster locally. Neutrinos should be more abundant at the Earth position than at an average point in the Universe. This fact may enhance the expected event rate in any future experiment. Past calculations of the local neutrino clustering factor only considered a spherical distribution of matter in the Milky Way and neglected the influence of other nearby objects like the Virgo cluster, although recent N-body simulations suggest that the latter may actually be important. In this paper, we adopt a back-tracking technique, well established in the calculation of cosmic rays fluxes, to perform the first three-dimensional calculation of the number density of relic neutrinos at the Solar System, taking into account not only the matter composition of the Milky Way, but also the contribution of the Andromeda galaxy and the Virgo cluster. The effect of Virgo is indeed found to be relevant and to depend non-trivially on the value of the neutrino mass. Our results show that the local neutrino density is enhanced by 0.53% for a neutrino mass of 10 meV, 12% for 50 meV, 50% for 100 meV or 500% for 300 meV.
|
Merle, A., Platscher, M., Rojas, N., Valle, J. W. F., & Vicente, A. (2016). Consistency of WIMP Dark Matter as radiative neutrino mass messenger. J. High Energy Phys., 07(7), 013–17pp.
Abstract: The scotogenic scenario provides an attractive approach to both Dark Matter and neutrino mass generation, in which the same symmetry that stabilises Dark Matter also ensures the radiative seesaw origin of neutrino mass. However the simplest scenario may suffer from inconsistencies arising from the spontaneous breaking of the underlying Z(2) symmetry. Here we show that the singlet-triplet extension of the simplest model naturally avoids this problem due to the presence of scalar triplets neutral under the Z(2) which affect the evolution of the couplings in the scalar sector. The scenario offers good prospects for direct WIMP Dark Matter detection through the nuclear recoil method.
|
Menjo, H. et al, Faus-Golfe, A., & Velasco, J. (2011). Monte Carlo study of forward pi(0) production spectra to be measured by the LHCf experiment for the purpose of benchmarking hadron interaction models at 10(17) eV. Astropart Phys., 34(7), 513–520.
Abstract: The LHCf experiment aims to improve knowledge of forward neutral particle production spectra at the LHC energy which is relevant for the interpretation of air shower development of high energy cosmic rays. Two detectors, each composed of a pair of sampling and imaging calorimeters, have been installed at the forward region of IP1 to measure pi(0) energy spectra above 600 GeV. In this paper, we present a Monte Carlo study of the pi(0) measurements to be performed with one of the LHCf detectors for proton-proton collisions at root s = 14 TeV. In approximately 40 min of operation at luminosity 0.8 x 10(29) cm(-2) s(-1) during the beam commissioning phase of LHC, about 1.5 x 10(4) pi(0) events are expected to be obtained at two transverse positions of the detector. The backgrounds from interactions of secondary particles with beam pipes and interactions of beam particles with residual gas in the beam pipes are expected to be less than 0.1% of the signal from pi(0)s. We also discuss the capability of LHCf measurements to discriminate between the various hadron interaction models that are used for simulation of high energy air showers, such as DPMJET3.03, QGSJETII-03, SIBYLL2.1 and EPOS1.99.
|
Mengoni, D., Duenas, J. A., Assie, M., Boiano, C., John, P. R., Aliaga, R. J., et al. (2014). Digital pulse-shape analysis with a TRACE early silicon prototype. Nucl. Instrum. Methods Phys. Res. A, 764, 241–246.
Abstract: A highly segmented silicon-pad detector prototype has been tested to explore the performance of the digital pulse shape analysis in the discrimination of the particles reaching the silicon detector. For the first time a 200 tun thin silicon detector, grown using an ordinary floating zone technique, has been shown to exhibit a level discrimination thanks to the fine segmentation. Light-charged particles down to few MeV have been separated, including their punch-through. A coaxial HPGe detector in time coincidence has further confirmed the quality of the particle discrimination.
|
Mendoza, S., & Olmo, G. J. (2015). Astrophysical constraints and insights on extended relativistic gravity. Astrophys. Space Sci., 357(2), 133–6pp.
Abstract: We give precise details to support that observations of gravitational lensing at scales of individual, groups and clusters of galaxies can be understood in terms of nonNewtonian gravitational interactions with a relativistic structure compatible with the Einstein Equivalence Principle. This result is derived on very general grounds without knowing the underlying structure of the gravitational field equations. As such, any developed gravitational theory built to deal with these astrophysical scales needs to reproduce the obtained results of this article.
|
Mendoza, E., Alcayne, V., Cano-Ott, D., Gonzalez-Romero, E., Martinez, T., de Rada, A. P., et al. (2023). Neutron capture measurements with high efficiency detectors and the Pulse Height Weighting Technique. Nucl. Instrum. Methods Phys. Res. A, 1047, 167894–16pp.
Abstract: Neutron capture cross section measurements in time-of-flight facilities are usually performed by detecting the prompt 7-rays emitted in the capture reactions. One of the difficulties to be addressed in these measurements is that the emitted 7-rays may change with the neutron energy, and therefore also the detection efficiency. To deal with this situation, many measurements use the so called Total Energy Detection (TED) technique, usually in combination with the Pulse Height Weighting Technique (PHWT). With it, it is sought that the detection efficiency depends only on the total energy of the 7-ray cascade, which does not vary much with the neutron energy. This technique was developed in the 1960s and has been used in many neutron capture experiments to date. One of the requirements of the technique is that 7-ray detectors have a low efficiency. This has meant that the PHWT has been used with experimental setups with low detection efficiencies. However, this condition does not have to be fulfilled by the experimental system as a whole. The main goal of this work is to show that it is possible to measure with a high efficiency detection system that uses the PHWT, and how to analyze the measured data.
|