n_TOF Collaboration(Mastromarco, M. et al), Domingo-Pardo, C., & Tain, J. L. (2019). Cross section measurements of Gd-155,Gd-157(n,) induced by thermal and epithermal neutrons. Eur. Phys. J. A, 55(1), 9–20pp.
Abstract: Neutron capture cross section measurements on Gd-155 and Gd-157 were performed using the time-of-flight technique at the nTOF facility at CERN on isotopically enriched samples. The measurements were carried out in the nTOF experimental area EAR1, at 185 m from the neutron source, with an array of 4 C6D6 liquid scintillation detectors. At a neutron kinetic energy of 0.0253 eV, capture cross sections of 62.2(2.2) and 239.8(8.4) kilobarn have been derived for Gd-155 and Gd-157, respectively, with up to 6% deviation relative to values presently reported in nuclear data libraries, but consistent with those values within 1.6 standard deviations. A resonance shape analysis has been performed in the resolved resonance region up to 181 eV and 307 eV, respectively for Gd-155 and Gd-157, where on average, resonance parameters have been found in good agreement with evaluations. Above these energies and up to 1 keV, the observed resonance-like structure of the cross section has been analysed and characterised. From a statistical analysis of the observed neutron resonances we deduced: neutron strength function of 2.01(28)x10-4 and 2.17(41)x10-4; average total radiative width of 106.8(14) meV and 101.1(20) meV and s-wave resonance spacing 1.6(2) eV and 4.8(5) eV for n + Gd-155 and n + Gd-157 systems, respectively.
|
n_TOF Collaboration(Mastromarco, M. et al), Domingo-Pardo, C., & Tain, J. L. (2022). High accuracy, high resolution U-235(n,f) cross section from n_TOF (CERN) from 18 meV to 10 keV. Eur. Phys. J. A, 58(8), 147–13pp.
Abstract: The U-235(n,f) cross section was measured in a wide energy range (18 meV-170 keV) at the nTOF facility at CERN, relative to Li-6(n,t) and B-10(n,alpha) standard reactions, with high resolution and accuracy, with a setup based on a stack of six samples and six silicon detectors placed in the neutron beam. In this paper we report on the results in the region between 18 meV and 10 keV neutron energy. A resonance analysis has been performed up to 200 eV, with the code SAMMY. The resulting fission kernels are compared with the ones extracted on the basis of the resonance parameters of the most recent major evaluated data libraries. A comparison of the nTOF data with the evaluated cross sections is also performed from thermal to 10 keV neutron energy for the energy-averaged cross section in energy groups of suitably chosen width. A good agreement, within 0.5%, is found on average between the new results and the latest evaluated data files ENDF/B-VIII.0 and JEFF-3.3, as well as with respect to the broad group average fission cross section established in the framework of the standard working group of IAEA (the so-called reference file). However, some discrepancies, of up to 4%, are still present in some specific energy regions. The new dataset here presented, characterized by a unique combination of high resolution and accuracy, low background and wide energy range, can help to improve the evaluations from the Resolved Resonance Region up to 10 keV, also reducing the uncertainties that affect this region.
|
n_TOF Collaboration(Lederer-Woods, C. et al), Domingo-Pardo, C., Tain, J. L., & Tarifeño-Saldivia, A. (2022). Ge-74(n, gamma) cross section below 70 keV measured at n_TOF CERN. Eur. Phys. J. A, 58(12), 239–9pp.
Abstract: Neutron capture reaction cross sections on Ge-74 are of importance to determine Ge-74 production during the astrophysical slow neutron capture process. We present new resonance data on Ge-74(n, gamma ) reactions below 70 keV neutron energy. We calculate Maxwellian averaged cross sections, combining our data below 70 keV with evaluated cross sections at higher neutron energies. Our stellar cross sections are in agreement with a previous activation measurement performed at Forschungszentrum Karlsruhe by Marganiec et al., once their data has been re-normalised to account for an update in the reference cross section used in that experiment.
|
n_TOF Collaboration(Guerrero, C. et al), Giubrone, G., & Tain, J. L. (2012). Simultaneous measurement of neutron-induced capture and fission reactions at CERN. Eur. Phys. J. A, 48(3), 29–9pp.
Abstract: The measurement of the capture cross-section of fissile elements, of utmost importance for the design of innovative nuclear reactors and the management of nuclear waste, faces particular difficulties related to the.-ray background generated in the competing fission reactions. At the CERN neutron time-of-flight facility nTOF we have combined the Total Absorption Calorimeter (TAC) capture detector with a set of three U-235 loaded MicroMegas (MGAS) fission detectors for measuring simultaneously two reactions: capture and fission. The results presented here include the determination of the three detection efficiencies involved in the process: epsilon(TAC)(n, f), epsilon(TAC)(n, gamma) and epsilon(MGAS)(n, f). In the test measurement we have succeeded in measuring simultaneously with a high total efficiency the U-235 capture and fission cross-sections, disentangling accurately the two types of reactions. The work presented here proves that accurate capture cross-section measurements of fissile isotopes are feasible at nTOF.
|
n_TOF Collaboration(Guerrero, C. et al), Domingo-Pardo, C., Giubrone, G., & Tain, J. L. (2013). Performance of the neutron time-of-flight facility n_TOF at CERN. Eur. Phys. J. A, 49(2), 27–15pp.
Abstract: The neutron time-of-flight facility n_TOF features a white neutron source produced by spallation through 20 GeV/c protons impinging on a lead target. The facility, aiming primarily at the measurement of neutron-induced reaction cross sections, was operating at CERN between 2001 and 2004, and then underwent a major upgrade in 2008. This paper presents in detail all the characteristics of the new neutron beam in the currently available configurations, which correspond to two different collimation systems and two choices of neutron moderator. The characteristics discussed include the intensity and energy dependence of the neutron flux, the spatial profile of the beam, the in-beam background components and the energy resolution/broadening. The discussion of these features is based on dedicated measurements and Monte Carlo simulations, and includes estimations of the systematic uncertainties of the mentioned quantities.
|