|
Oliver, S., Gimenez-Alventosa, V., Berumen, F., Gimenez, V., Beaulieu, L., Ballester, F., et al. (2023). Benchmark of the PenRed Monte Carlo framework for HDR brachytherapy. Z. Med. Phys., 33(4), 511–528.
Abstract: Purpose: The purpose of this study is to validate the PenRed Monte Carlo framework for clinical applications in brachytherapy. PenRed is a C++ version of Penelope Monte Carlo code with additional tallies and utilities. Methods and materials: Six benchmarking scenarios are explored to validate the use of PenRed and its improved bachytherapy-oriented capabilities for HDR brachytherapy. A new tally allowing the evaluation of collisional kerma for any material using the track length kerma estimator and the possibility to obtain the seed positions, weights and directions processing directly the DICOM file are now implemented in the PenRed distribution. The four non-clinical test cases developed by the Joint AAPM-ESTRO-ABG-ABS WG-DCAB were evaluated by comparing local and global absorbed dose differences with respect to established reference datasets. A prostate and a palliative lung cases, were also studied. For them, absorbed dose ratios, global absorbed dose differences, and cumulative dose-volume histograms were obtained and discussed. Results: The air-kerma strength and the dose rate constant corresponding to the two sources agree with the reference datatests within 0.3% (Sk) and 0.1% (K). With respect to the first three WG-DCAB test cases, more than 99.8% of the voxels present local (global) differences within +/- 1%(+/- 0.1%) of the reference datasets. For test Case 4 reference dataset, more than 94.9%(97.5%) of voxels show an agreement within +/- 1%(+/- 0.1%), better than similar benchmarking calculations in the literature. The track length kerma estimator scorer implemented increases the numerical efficiency of brachytherapy calculations two orders of magnitude, while the specific brachytherapy source allows the user to avoid the use of error-prone intermediate steps to translate the DICOM information into the simulation. In both clinical cases, only minor absorbed dose differences arise in the low-dose isodoses. 99.8% and 100% of the voxels have a global absorbed dose difference ratio within +/- 0.2%for the prostate and lung cases, respectively. The role played by the different segmentation and composition material in the bone structures was discussed, obtaining negligible absorbed dose differ-ences. Dose-volume histograms were in agreement with the reference data.Conclusions: PenRed incorporates new tallies and utilities and has been validated for its use for detailed and precise high-dose-rate brachytherapy simulations.
|
|
|
Olivares Herrador, J., Latina, A., Aksoy, A., Fuster Martinez, N., Gimeno, B., & Esperante, D. (2024). Implementation of the beam-loading effect in the tracking code RF-track based on a power-diffusive model. Front. Physics, 12, 1348042–11pp.
Abstract: The need to achieve high energies in particle accelerators has led to the development of new accelerator technologies, resulting in higher beam intensities and more compact devices with stronger accelerating fields. In such scenarios, beam-loading effects occur, and intensity-dependent gradient reduction affects the accelerated beam as a consequence of its interaction with the surrounding cavity. In this study, a power-diffusive partial differential equation is derived to account for this effect. Its numerical resolution has been implemented in the tracking code RF-Track, allowing the simulation of apparatuses where transient beam loading plays an important role. Finally, measurements of this effect have been carried out in the CERN Linear Electron Accelerator for Research (CLEAR) facility at CERN, finding good agreement with the RF-Track simulations.
|
|
|
Oldengott, I. M., Barenboim, G., Kahlen, S., Salvado, J., & Schwarz, D. J. (2019). How to relax the cosmological neutrino mass bound. J. Cosmol. Astropart. Phys., 04(4), 049–18pp.
Abstract: We study the impact of non-standard momentum distributions of cosmic neutrinos on the anisotropy spectrum of the cosmic microwave background and the matter power spectrum of the large scale structure. We show that the neutrino distribution has almost no unique observable imprint, as it is almost entirely degenerate with the effective number of neutrino flavours, N-eff, and the neutrino mass, m(nu). Performing a Markov chain Monte Carlo analysis with current cosmological data, we demonstrate that the neutrino mass bound heavily depends on the assumed momentum distribution of relic neutrinos. The message of this work is simple and has to our knowledge not been pointed out clearly before: cosmology allows that neutrinos have larger masses if their average momentum is larger than that of a perfectly thermal distribution. Here we provide an example in which the mass limits are relaxed by a factor of two.
|
|
|
O'Hare, C. A. J., Caputo, A., Millar, A. J., & Vitagliano, E. (2020). Axion helioscopes as solar magnetometers. Phys. Rev. D, 102(4), 043019–19pp.
Abstract: Axion helioscopes search for solar axions and axionlike particles via inverse Primakoff conversion in strong laboratory magnets pointed at the Sun. Anticipating the detection of solar axions, we determine the potential for the planned next-generation helioscope, the International Axion Observatory (IAXO), to measure or constrain the solar magnetic field. To do this we consider a previously neglected component of the solar axion flux at sub-keV energies arising from the conversion of longitudinal plasmons. This flux is sensitively dependent to the magnetic field profile of the Sun, with lower energies corresponding to axions converting into photons at larger solar radii. If the detector technology eventually installed in IAXO has an energy resolution better than 200 eV, then solar axions could become an even more powerful messenger than neutrinos of the magnetic field in the core of the Sun. For energy resolutions better than 10 eV, IAXO could access the inner 70% of the Sun and begin to constrain the field at the tachocline: the boundary between the radiative and convective zones. The longitudinal plasmon flux from a toroidal magnetic field also has an additional 2% geometric modulation effect which could be used to measure the angular dependence of the magnetic field.
|
|
|
n_TOF Collaboration(Wright, T. et al), Domingo-Pardo, C., & Tain, J. L. (2024). Measurement of the prompt fission γ-rays from slow neutron-induced fission of 235U with STEFF. Eur. Phys. J. A, 60(3), 70–11pp.
Abstract: The amount of energy carried by gamma-rays during the fission process is an important consideration when developing new reactor designs. Many studies of gamma-ray energy and multiplicity, from a multitude of fissioning systems, were measured during the 1970s. However the data from such experiments largely underestimates the heating effect caused by gamma-rays in the structure of a reactor. It is therefore essential to obtain more accurate measurements of the energy carried during gamma-ray emission. As such, the OECD Nuclear Energy Agency has put out a high priority request [1] for measurements of the mean gamma-ray energy and multiplicity to an accuracy better than 7.5 percent from several fissioning systems; including U-235(n(thermal)). Measurements of the rays from these fissioning nuclei were performed with the SpecTrometer for Exotic Fission Fagments (STEFF).
|
|