|
Escudero, M., Berlin, A., Hooper, D., & Lin, M. X. (2016). Toward (finally!) ruling out Z and Higgs mediated dark matter models. J. Cosmol. Astropart. Phys., 12(12), 029–21pp.
Abstract: In recent years, direct detection, indirect detection, and collider experiments have placed increasingly stringent constraints on particle dark matter, exploring much of the parameter space associated with the WIMP paradigm. In this paper, we focus on the subset of WIMP models in which the dark matter annihilates in the early universe through couplings to either the Standard Model Z or the Standard Model Higgs boson. Considering fermionic, scalar, and vector dark matter candidates within a model-independent context, we fi nd that the overwhelming majority of these dark matter candidates are already ruled out by existing experiments. In the case of Z mediated dark matter, the only scenarios that are not currently excluded are those in which the dark matter is a fermion with an axial coupling and with a mass either within a few GeV of the Z resonance (m(D M) similar or equal to m(Z)/2) or greater than 200 GeV, or with a vector coupling and with m(DM) > 6TeV. Several Higgs mediated scenarios are currently viable if the mass of the dark matter is near the Higgs pole (m(DM) similar or equal to m(H) /2). Otherwise, the only scenarios that are not excluded are those in which the dark matter is a scalar (vector) heavier than 400 GeV (1160 GeV) with a Higgs portal coupling, or a fermion with a pseudoscalar (CP violating) coupling to the Standard Model Higgs boson. With the exception of dark matter with a purely pseudoscalar coupling to the Higgs, it is anticipated that planned direct detection experiments will probe nearly the entire range of models considered in this study.
|
|
|
Double Chooz collaboration(Abe, Y. et al), & Novella, P. (2016). Measurement of theta(13) in Double Chooz using neutron captures on hydrogen with novel background rejection techniques. J. High Energy Phys., 01(1), 163–29pp.
Abstract: The Double Chooz collaboration presents a measurement of the neutrino mixing angle theta(13) using reactor (nu) over bar (e) observed via the inverse beta decay reaction in which the neutron is captured on hydrogen. This measurement is based on 462.72 live days data, approximately twice as much data as in the previous such analysis, collected with a detector positioned at an average distance of 1050m from two reactor cores. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties. Accidental coincidences, the dominant background in this analysis, are suppressed by more than an order of magnitude with respect to our previous publication by a multi-variate analysis. These improvements demonstrate the capability of precise measurement of reactor (nu) over bar (e) without gadolinium loading. Spectral distortions from the (nu) over bar (e) reactor flux predictions previously reported with the neutron capture on gadolinium events are confirmed in the independent data sample presented here. A value of sin(2) 2 theta(13) = 0.095(0.039)(+0.039)(stat+syst) is obtained from a fit to the observed event rate as a function of the reactor power, a method insensitive to the energy spectrum shape. A simultaneous fit of the hydrogen capture events and of the gadolinium capture events yields a measurement of sin(2) 2 theta(13) = 0.088 +/- 0.033(stat+syst).
|
|
|
Double Chooz collaboration(Abe, Y. et al), & Novella, P. (2016). Muon capture on light isotopes measured with the Double Chooz detector. Phys. Rev. C, 93(5), 054608–18pp.
Abstract: Using the Double Chooz detector, designed to measure the neutrino mixing angle theta(13), the products of mu(-) capture on C-12, C-13, N-14, and O-16 have been measured. Over a period of 489.5 days, 2.3 x 10(6) stopping cosmic mu(-) have been collected, of which 1.8 x 10(5) captured on carbon, nitrogen, or oxygen nuclei in the inner detector scintillator or acrylic vessels. The resulting isotopes were tagged using prompt neutron emission (when applicable), the subsequent beta decays, and, in some cases, beta-delayed neutrons. The most precise measurement of the rate of C-12(mu(-), nu)B-12 to date is reported: 6.57(-0.21)(+0.11) x 10(3) s(-1), or (17.35(-0.59)(+0.35))% of nuclear captures. By tagging excited states emitting gamma s, the ground state transition rate to B-12 has been determined to be 5.68(-0.23)(+0.14) x 10(3) s(-1). The heretofore unobserved reactions C-12(mu(-), nu alpha)Li-8, C-13(mu(-), nu n alpha)Li-8, and C-13(mu(-), nu n)B-12 are measured. Further, a population of beta n decays following stopping muons is identified with 5.5 sigma significance. Statistics limit our ability to identify these decays definitively. Assuming negligible production of He-8, the reaction C-13(mu(-), nu alpha)Li-9 is found to be present at the 2.7 sigma level. Limits are set on a variety of other processes.
|
|
|
Double Chooz collaboration(Abe, Y. et al), & Novella, P. (2016). Characterization of the spontaneous light emission of the PMTs used in the Double Chooz experiment. J. Instrum., 11, P08001–25pp.
Abstract: During the commissioning of the first of the two detectors of the Double Chooz experiment, an unexpected and dominant background caused by the emission of light inside the optical volume has been observed. A specific study of the ensemble of phenomena called Light Noise has been carried out in-situ, and in an external laboratory, in order to characterize the signals and to identify the possible processes underlying the effect. Some mechanisms of instrumental noise originating from the PMTs were identified and it has been found that the leading one arises from the light emission localized on the photomultiplier base and produced by the combined effect of heat and high voltage across the transparent epoxy resin covering the electric components. The correlation of the rate and the amplitude of the signal with the temperature has been observed. For the first detector in operation the induced background has been mitigated using online and offline analysis selections based on timing and light pattern of the signals, while a modification of the photomultiplier assembly has been implemented for the second detector in order to blacken the PMT bases.
|
|
|
Donini, A., & Marimon, S. G. (2016). Micro-orbits in a many-brane model and deviations from Newton's 1/r(2) law. Eur. Phys. J. C, 76(12), 696–21pp.
Abstract: We consider a five-dimensional model with geometry M = M-4 x S-1, with compactification radius R. The Standard Model particles are localized on a brane located at y = 0, with identical branes localized at different points in the extra dimension. Objects located on our brane can orbit around objects located on a brane at a distance d = y/R, with an orbit and a period significantly different from the standard Newtonian ones. We study the kinematical properties of the orbits, finding that it is possible to distinguish one motion from the other in a large region of the initial conditions parameter space. This is a warm-up to study if a SM-like mass distribution on one (or more) distant brane(s) may represent a possible dark matter candidate. After using the same technique to the study of orbits of objects lying on the same brane (d = 0), we apply this method to the detection of generic deviations from the inverse-square Newton law. We propose a possible experimental setup to look for departures from Newtonian motion in the micro-world, finding that an order of magnitude improvement on present bounds can be attained at the 95% CL under reasonable assumptions.
|
|