Steinhardt, T., Eberth, J., Skoda, S., Thelen, O., Schwengner, R., Donau, F., et al. (2012). Stabilization of prolate deformation at high spin in Kr-75. Phys. Rev. C, 86(6), 064310–16pp.
Abstract: The neutron-deficient nucleus Kr-75 has been studied in two EUROBALL experiments. The analysis yielded a considerably extended level scheme including two newly observed excited high spin bands. The results are interpreted in the framework of the cranked Nilsson-Strutinsky approach. The calculations compare well to the experimentally established level scheme and predict the nucleus to be mainly prolate or triaxially deformed at high spin. Evidence for an oblate-prolate shape coexistence could not be found at high spin.
|
|
|
Montanari, D., Farnea, E., Leoni, S., Pollarolo, G., Corradi, L., Benzoni, G., et al. (2011). Response function of the magnetic spectrometer PRISMA. Eur. Phys. J. A, 47(1), 4–7pp.
Abstract: The response function of the magnetic spectrometer PRISMA is studied via a Monte Carlo simulation that employs a ray tracing code to determine the trajectories of individual rays through the electromagnetic fields. The calculated response is tested on angular and energy distributions provided by theoretical calculations for the Ca-48 + Ni-64 multinucleon transfer reaction and applied to the corresponding experimental data.
|
|
|
Marginean, R., Rusu, C., Marginean, N., Bucurescu, D., Ur, C. A., de Angelis, G., et al. (2012). High-spin structure of Pd-95. Phys. Rev. C, 86(3), 034339–9pp.
Abstract: The level scheme of the neutron-deficient nucleus Pd-95 has been studied with the Ni-58 + Ca-40 fusion-evaporation reaction at 135 MeV with the GASP gamma-ray array, the ISIS silicon ball, and the N-ring neutron detector. Excited levels with spins at least up to 45/2 (h) over bar are reported for both parities. The observed experimental data are compared to large-scale shell-model calculations.
|
|
|
Jaworski, G., Palacz, M., Nyberg, J., de Angelis, G., de France, G., Di Nitto, A., et al. (2012). Monte Carlo simulation of a single detector unit for the neutron detector array NEDA. Nucl. Instrum. Methods Phys. Res. A, 673, 64–72.
Abstract: A study of the dimensions and performance of a single detector of the future neutron detector array NEDA was performed by means of Monte Carlo simulations, using GEANT4. Two different liquid scintillators were evaluated: the hydrogen based BC501A and the deuterated BC537. The efficiency and the probability that one neutron will trigger a signal in more than one detector were investigated as a function of the detector size. The simulations were validated comparing the results to experimental measurements performed with two existing neutron detectors, with different geometries, based on the liquid scintillator BC501.
|
|
|
Goasduff, A., Valiente-Dobon, J. J., Lunardi, S., Haas, F., Gadea, A., de Angelis, G., et al. (2014). Counting rate measurements for lifetime experiments using the RDDS method with the new generation gamma-ray array AGATA. Nucl. Instrum. Methods Phys. Res. A, 758, 1–3.
Abstract: The differential Recoil Distance Doppler Shift (RDDS) method after multinucleon transfer (MNT) reactions to measure lifetimes of excited states in neutron-rich nuclei requires the use of a thick energy degrader for the recoiling ejectiles that are then detected in a spectrometer. This type of measurements greatly benefits from the use of the new generation segmented gamma-ray detectors, such as the AGATA demonstrator which offers unprecedented energy and angular resolutions. In order to make an optimized choice of the material and the thickness of the degrader for lifetime measurements using the RODS method after MNT, an experiment has been performed with the AGATA demonstrator. Counting rate measurements for different degraders are presented.
|
|