Grodner, E. et al, Gadea, A., Algora, A., Agramunt, J., Domingo-Pardo, C., Molina, F., et al. (2014). Hindered Gamow-Teller Decay to the Odd-Odd N = Z Ga-62: Absence of Proton-Neutron T=0 Condensate in A=62. Phys. Rev. Lett., 113(9), 092501–5pp.
Abstract: Search for a new kind of superfluidity built on collective proton-neutron pairs with aligned spin is performed studying the Gamow-Teller decay of the T = 1, J(pi) = 0(+) ground state of Ge-62 into excited states of the odd-odd N = Z nucleus Ga-62. The experiment is performed at GSI Helmholtzzentrum fur Shwerionenforshung with the Ge-62 ions selected by the fragment separator and implanted in a stack of Si-strip detectors, surrounded by the RISING Ge array. A half-life of T-1/2 = 2 82.9(14) ms is measured for the Ge-62 ground state. Six excited states of Ga-62, populated below 2.5 MeV through Gamow-Teller transitions, are identified. Individual Gamow-Teller transition strengths agree well with theoretical predictions of the interacting shell model and the quasiparticle random phase approximation. The absence of any sizable low-lying Gamow-Teller strength in the reported beta-decay experiment supports the hypothesis of a negligible role of coherent T = 0 proton-neutron correlations in Ga-62.
|
Hadynska-Klek, K. et al, & Gadea, A. (2013). Towards the determination of superdeformation in Ca-42. Acta Phys. Pol. B, 44(3), 617–625.
Abstract: The Coulomb excitation experiment to study electromagnetic structure of low-lying states in Ca-42 with a focus on a possible superdeformation in this nucleus was performed at the Laboratori Nazionali di Legnaro in Italy. Preliminary values of the determined quadrupole deformation parameters for both the ground state band and the presumed superdeformed band are presented.
|
Huyuk, T. et al, Gadea, A., Aliaga-Varea, R. J., & Domingo-Pardo, C. (2016). Conceptual design of the early implementation of the NEutron Detector Array (NEDA) with AGATA. Eur. Phys. J. A, 52(3), 55–8pp.
Abstract: The NEutron Detector Array (NEDA) project aims at the construction of a new high-efficiency compact neutron detector array to be coupled with large gamma-ray arrays such as AGATA. The application of NEDA ranges from its use as selective neutron multiplicity filter for fusion-evaporation reaction to a large solid angle neutron tagging device. In the present work, possible configurations for the NEDA coupled with the Neutron Wall for the early implementation with AGATA has been simulated, using Monte Carlo techniques, in order to evaluate their performance figures. The goal of this early NEDA implementation is to improve, with respect to previous instruments, efficiency and capability to select multiplicity for fusion-evaporation reaction channels in which 1, 2 or 3 neutrons are emitted. Each NEDA detector unit has the shape of a regular hexagonal prism with a volume of about 3.23 l and it is filled with the EJ301 liquid scintillator, that presents good neutron-gamma discrimination properties. The simulations have been performed using a fusion-evaporation event generator that has been validated with a set of experimental data obtained in the Ni-58 + Fe-56 reaction measured with the Neutron Wall detector array.
|
Jaworski, G., Palacz, M., Nyberg, J., de Angelis, G., de France, G., Di Nitto, A., et al. (2012). Monte Carlo simulation of a single detector unit for the neutron detector array NEDA. Nucl. Instrum. Methods Phys. Res. A, 673, 64–72.
Abstract: A study of the dimensions and performance of a single detector of the future neutron detector array NEDA was performed by means of Monte Carlo simulations, using GEANT4. Two different liquid scintillators were evaluated: the hydrogen based BC501A and the deuterated BC537. The efficiency and the probability that one neutron will trigger a signal in more than one detector were investigated as a function of the detector size. The simulations were validated comparing the results to experimental measurements performed with two existing neutron detectors, with different geometries, based on the liquid scintillator BC501.
|
Jungclaus, A. et al, Gadea, A., & Montaner-Piza, A. (2016). First observation of gamma rays emitted from excited states south-east of Sn-132: The pi g(9/2)(-1) circle times nu f(7/2) multiplet of In-132(83). Phys. Rev. C, 93(4), 041301–6pp.
Abstract: For the first time, the gamma decay of excited states has been observed in a nucleus situated in the quadrant south-east of doubly magic Sn-132, a region in which experimental information so far is limited to ground-state properties. Six gamma rays with energies of 50, 86, 103, 227, 357, and 602 keV were observed following the beta-delayed neutron emission from Cd-133(85), populated in the projectile fission of a U-238 beam at the Radioactive Isotope Beam Factory at RIKEN within the EURICA project. The new experimental information is compared to the results of a modern realistic shell-model calculation, the first one in this region very far from stability, focusing in particular on the pi 0g(9/2)(-1) circle times nu 1f(7/2) particle-hole multiplet in In-132(83). In addition, theoretical estimates based on a scaling of the two-body matrix elements for the pi h(11/2)(-1) circle times nu g(9/2) analog multiplet in Tl-208(127), one major proton and one major neutron shell above, are presented.
|