|
MoEDAL Collaboration(Acharya, B. et al), Bernabeu, J., Garcia, C., Mamuzic, J., Mitsou, V. A., Ruiz de Austri, R., et al. (2017). Search for Magnetic Monopoles with the MoEDAL Forward Trapping Detector in 13 TeV Proton-Proton Collisions at the LHC. Phys. Rev. Lett., 118(6), 061801–6pp.
Abstract: MoEDAL is designed to identify new physics in the form of long-lived highly ionizing particles produced in high-energy LHC collisions. Its arrays of plastic nuclear-track detectors and aluminium trapping volumes provide two independent passive detection techniques. We present here the results of a first search for magnetic monopole production in 13 TeV proton-proton collisions using the trapping technique, extending a previous publication with 8 TeV data during LHC Run 1. A total of 222 kg of MoEDAL trapping detector samples was exposed in the forward region and analyzed by searching for induced persistent currents after passage through a superconducting magnetometer. Magnetic charges exceeding half the Dirac charge are excluded in all samples and limits are placed for the first time on the production of magnetic monopoles in 13 TeV pp collisions. The search probes mass ranges previously inaccessible to collider experiments for up to five times the Dirac charge.
|
|
|
Miyahara, K., Hyodo, T., Oka, M., Nieves, J., & Oset, E. (2017). Theoretical study of the Xi(1620) and Xi(1690) resonances in Xi(c)-> pi(+) MB decays. Phys. Rev. C, 95(3), 035212–12pp.
Abstract: Nonleptonic weak decays of Xi(c) into pi(+) and a meson (M)-baryon (B) final state, MB, are analyzed from the viewpoint of probing S = -2 baryon resonances, i.e., Xi(1620) and Xi(1690), of which spin-parity and other properties are not well known. We argue that the weak decay of Xi(c) is dominated by a single quark-line diagram, preferred by the Cabibbo-Kobayashi-Maskawa coefficient, color recombination factor, the diquark correlation, and the kinematical condition. The decay process has an advantage of being free from meson resonances in the p+ M invariantmass distribution. The invariant mass distribution of the meson-baryon final state is calculated with three different chiral unitary approaches, assuming that the Xi(1620) and Xi(1690) resonances have J(P) = 1/2(-). It is found that a clear peak for the Xi(1690) is seen in the pi Xi and K Lambda spectra. We also suggest that the ratios of the pi Xi, K Lambda, and K Sigma final states are useful to distinguish whether the peak is originated from the Xi(1690) resonance or it is a K Sigma threshold effect.
|
|
|
Menchon, C. C., Olmo, G. J., & Rubiera-Garcia, D. (2017). Nonsingular black holes, wormholes, and de Sitter cores from anisotropic fluids. Phys. Rev. D, 96(10), 104028–16pp.
Abstract: We study Born-Infeld gravity coupled to an anisotropic fluid in a static, spherically symmetric background. The free function characterizing the fluid is selected on the following grounds: i) recovery of the Reissner-Nordstrom solution of General Relativity at large distances, ii) fulfillment of classical energy conditions, and iii) inclusion of models of nonlinear electrodynamics as particular examples. Four branches of solutions are obtained, depending on the signs of two parameters on the gravity and matter sectors. On each branch, we discuss in detail the modifications on the innermost region of the corresponding solutions, which provides a plethora of configurations, including nonsingular black holes and naked objects, wormholes, and de Sitter cores. The regular character of these configurations is discussed according to the completeness of geodesics and the behavior of curvature scalars.
|
|
|
Marquez-Martin, I., Di Molfetta, G., & Perez, A. (2017). Fermion confinement via quantum walks in (2+1)-dimensional and (3+1)-dimensional space-time. Phys. Rev. A, 95(4), 042112–5pp.
Abstract: We analyze the properties of a two-and three-dimensional quantum walk that are inspired by the idea of a brane-world model put forward by Rubakov and Shaposhnikov [Phys. Lett. B 125, 136 (1983)]. In that model, particles are dynamically confined on the brane due to the interaction with a scalar field. We translated this model into an alternate quantum walk with a coin that depends on the external field, with a dependence which mimics a domain wall solution. As in the original model, fermions (in our case, the walker) become localized in one of the dimensions, not from the action of a random noise on the lattice (as in the case of Anderson localization) but from a regular dependence in space. On the other hand, the resulting quantum walk can move freely along the “ordinary” dimensions.
|
|
|
Marco-Hernandez, R., Bau, M., Ferrari, M., Ferrari, V., Pedersen, F., & Soby, L. (2017). A Low-Noise Charge Amplifier for the ELENA Trajectory, Orbit, and Intensity Measurement System. IEEE Trans. Nucl. Sci., 64(9), 2465–2473.
Abstract: A low-noise head amplifier has been developed for the extra low energy antiproton ring beam trajectory, orbit, and intensity measurement system at CERN. This system is based on 24 double-electrode electrostatic beam position monitors installed around the ring. A head amplifier is placed close to each beam position monitor to amplify the electrode signals and generate a difference and a sum signal. These signals are sent to the digital acquisition system, about 50 m away from the ring, where they are digitized and further processed. The beam position can be measured by dividing the difference signal by the sum signal while the sum signal gives information relative to the beam intensity. The head amplifier consists of two discrete charge preamplifiers with junction field effect transistor (JFET) inputs, a sum and a difference stage, and two cable drivers. Special attention has been paid to the amplifier printed circuit board design to minimize the parasitic capacitances and inductances at the charge amplifier stages to meet the gain and noise requirements. The measurements carried out on the head amplifier showed a gain of 40.5 and 46.5 dB for the sum and difference outputs with a bandwidth from 200 Hz to 75 MHz and an input voltage noise density lower than 400 pV/v Hz. Twenty head amplifiers have been already installed in the ring and they have been used to detect the first beam signals during the first commissioning stage in November 2016.
|
|