Mongillo, M., Abdullahi, A., Banto Oberhauser, B., Crivelli, P., Hostert, M., Massaro, D., et al. (2023). Constraining light thermal inelastic dark matter with NA64. Eur. Phys. J. C, 83(5), 391–14pp.
Abstract: A vector portal between the Standard Model and the dark sector is a predictive and compelling framework for thermal dark matter. Through co-annihilations, models of inelastic dark matter (iDM) and inelastic Dirac dark matter (i2DM) can reproduce the observed relic density in the MeV to GeV mass range without violating cosmological limits. In these scenarios, the vector mediator behaves like a semi-visible particle, evading traditional bounds on visible or invisible resonances, and uncovering new parameter space to explain the muon (g – 2) anomaly. By means of a more inclusive signal definition at the NA64 experiment, we place new constraints on iDM and i2DM using a missing energy technique. With a recast-based analysis, we contextualize the NA64 exclusion limits in parameter space and estimate the reach of the newly collected and expected future NA64 data. Our results motivate the development of an optimized search program for semi-visible particles, in which fixed target experiments like NA64 provide a powerful probe in the sub-GeV mass range.
|
Molina, R., & Oset, E. (2023). T-cS (2900) as a threshold effect from the interaction of the D* K *, D *(s)rho channels. Phys. Rev. D, 107(5), 056015–7pp.
Abstract: We look at the mass distribution of the D(S)(+)i Pi(-) In the B-0 ->(DDS+)-D-0 Pi(-)decay, where a peak has been observed in the region of the D (*) (s)rho, D* K* thresholds. By creating these two channels together with a D (0) in B-0 decay and letting them interact as coupled channels, we obtain a structure around their thresholds, short of producing a bound state, which leads to a peak in the D-S(+) Pi(-)mass distribution in the B-0 -> (DDS+)-D-0 Pi(-)decay. We conclude that the interaction between the D*K* and D (*) (s)rho is essential to produce the cusp structure that we associate to the recently seen Tcs(2900), and that its experimental width is mainly due to the decay width of the rho meson. The peak obtained together with a smooth background reproduces fairly well the experimental mass distribution observed in the B (0)-> (DDS+)-D-0 Pi(-) decay.
|
Molina, R., Ikeno, N., & Oset, E. (2023). Sequential single pion production explaining the dibaryon “d*(2380)” peak. Chin. Phys. C, 47(4), 041001–10pp.
Abstract: In this study, we investigate the two step sequential one pion production mechanism, that is, np(I=0)->pi(-)pp followed by the fusion reaction pp ->pi(+)d, to describe the np ->pi(+)pi(-)d reaction with in state I = 0 . In this reaction, a narrow peak identified with a “ d(2380) ” dibaryon has been previously observed. We discover that the second reaction step pp ->pi(+)d is driven by a triangle singularity that determines the position of the peak of the reaction and the high strength of the cross section. The combined cross section of these two mechanisms produces a narrow peak with a position, width, and strength, that are compatible with experimental observations within the applied approximations made. This novel interpretation of the peak accomplished without invoking a dibaryon explains why this peak has remained undetected in other reactions.
|
Millar, W. L. et al, & Bañon Caballero, D. (2023). High-Power Test of Two Prototype X-Band Accelerating Structures Based on SwissFEL Fabrication Technology. IEEE Trans. Nucl. Sci., 70(1), 1–19.
Abstract: This article presents the design, construction, and high-power test of two $X$ -band radio frequency (RF) accelerating structures built as part of a collaboration between CERN and the Paul Scherrer Institute (PSI) for the compact linear collider (CLIC) study. The structures are a modified “tuning-free ” variant of an existing CERN design and were assembled using Swiss free electron laser (SwissFEL) production methods. The purpose of the study is two-fold. The first objective is to validate the RF properties and high-power performance of the tuning-free, vacuum brazed PSI technology. The second objective is to study the structures' high-gradient behavior to provide insight into the breakdown and conditioning phenomena as they apply to high-field devices in general. Low-power RF measurements showed that the structure field profiles were close to the design values, and both structures were conditioned to accelerating gradients in excess of 100 MV/m in CERN's high-gradient test facility. Measurements performed during the second structure test suggest that the breakdown rate (BDR) scales strongly with the accelerating gradient, with the best fit being a power law relation with an exponent of 31.14. In both cases, the test results indicate that stable, high-gradient operation is possible with tuning-free, vacuum brazed structures of this kind.
|
Mendoza, E., Alcayne, V., Cano-Ott, D., Gonzalez-Romero, E., Martinez, T., de Rada, A. P., et al. (2023). Neutron capture measurements with high efficiency detectors and the Pulse Height Weighting Technique. Nucl. Instrum. Methods Phys. Res. A, 1047, 167894–16pp.
Abstract: Neutron capture cross section measurements in time-of-flight facilities are usually performed by detecting the prompt 7-rays emitted in the capture reactions. One of the difficulties to be addressed in these measurements is that the emitted 7-rays may change with the neutron energy, and therefore also the detection efficiency. To deal with this situation, many measurements use the so called Total Energy Detection (TED) technique, usually in combination with the Pulse Height Weighting Technique (PHWT). With it, it is sought that the detection efficiency depends only on the total energy of the 7-ray cascade, which does not vary much with the neutron energy. This technique was developed in the 1960s and has been used in many neutron capture experiments to date. One of the requirements of the technique is that 7-ray detectors have a low efficiency. This has meant that the PHWT has been used with experimental setups with low detection efficiencies. However, this condition does not have to be fulfilled by the experimental system as a whole. The main goal of this work is to show that it is possible to measure with a high efficiency detection system that uses the PHWT, and how to analyze the measured data.
|