Jungclaus, A. et al, Gadea, A., & Montaner-Piza, A. (2024). Excited-State Half-Lives in 130 Cd and the Isospin Dependence of Effective Charges. Phys. Rev. Lett., 132(22), 222501–7pp.
Abstract: The known I pi = 8 & thorn; 1 , E x = 2129-keV isomer in the semimagic nucleus 130 Cd 82 was populated in the projectile fission of a 238 U beam at the Radioactive Isotope Beam Factory at RIKEN. The high counting statistics of the accumulated data allowed us to determine the excitation energy, E x = 2001.2(7) keV, and half-life, T 1 =2 = 57(3) ns, of the I pi = 6 & thorn; 1 state based on gamma gamma coincidence information. Furthermore, the halflife of the 8 & thorn; 1 state, T 1 =2 = 224(4) ns, was remeasured with high precision. The new experimental information, combined with available data for 134 Sn and large-scale shell model calculations, allowed us to extract proton and neutron effective charges for 132 Sn, a doubly magic nucleus far -off stability. A comparison to analogous information for 100 Sn provides first reliable information regarding the isospin dependence of the isoscalar and isovector effective charges in heavy nuclei.
|
Jaworski, G., Palacz, M., Nyberg, J., de Angelis, G., de France, G., Di Nitto, A., et al. (2012). Monte Carlo simulation of a single detector unit for the neutron detector array NEDA. Nucl. Instrum. Methods Phys. Res. A, 673, 64–72.
Abstract: A study of the dimensions and performance of a single detector of the future neutron detector array NEDA was performed by means of Monte Carlo simulations, using GEANT4. Two different liquid scintillators were evaluated: the hydrogen based BC501A and the deuterated BC537. The efficiency and the probability that one neutron will trigger a signal in more than one detector were investigated as a function of the detector size. The simulations were validated comparing the results to experimental measurements performed with two existing neutron detectors, with different geometries, based on the liquid scintillator BC501.
|
Huyuk, T. et al, Gadea, A., Aliaga-Varea, R. J., & Domingo-Pardo, C. (2016). Conceptual design of the early implementation of the NEutron Detector Array (NEDA) with AGATA. Eur. Phys. J. A, 52(3), 55–8pp.
Abstract: The NEutron Detector Array (NEDA) project aims at the construction of a new high-efficiency compact neutron detector array to be coupled with large gamma-ray arrays such as AGATA. The application of NEDA ranges from its use as selective neutron multiplicity filter for fusion-evaporation reaction to a large solid angle neutron tagging device. In the present work, possible configurations for the NEDA coupled with the Neutron Wall for the early implementation with AGATA has been simulated, using Monte Carlo techniques, in order to evaluate their performance figures. The goal of this early NEDA implementation is to improve, with respect to previous instruments, efficiency and capability to select multiplicity for fusion-evaporation reaction channels in which 1, 2 or 3 neutrons are emitted. Each NEDA detector unit has the shape of a regular hexagonal prism with a volume of about 3.23 l and it is filled with the EJ301 liquid scintillator, that presents good neutron-gamma discrimination properties. The simulations have been performed using a fusion-evaporation event generator that has been validated with a set of experimental data obtained in the Ni-58 + Fe-56 reaction measured with the Neutron Wall detector array.
|
Houarner, C., Boujrad, A., Tripon, M., Bezard, M., Blaizot, M., Bourgault, P., et al. (2025). NUMEXO2: a versatile digitizer for nuclear physics. J. Instrum., 20(5), T05004–21pp.
Abstract: NUMEXO2 is a 16 channels 14 bit/200 MHz digitizer and processing board initially developed for gamma-ray spectroscopy (for EXOGAM: EXOtic nuclei GAMma ray). NUMEXO2 has been gradually extended and improved as a general purpose digitizer to fulfill various needs in nuclear physics detection at GANIL. This was possible thanks to reprogrammable components like FPGAs and the optimization of different algorithms. The originality of this work compared to similar systems is that all numerical operations follow the digital data flow from ADCs, without any storage step of samples. Some details are given on digital processing of the signals, delivered by a large variety of detectors: HPGe, silicon strip detector, ionisation chamber, liquid and plastic scintillators read-out with photomultipliers, Multi Wire Proportional Counter and drift chamber. Thanks to this high versatility, the NUMEXO2 digitizer is extensively used at GANIL (Grand Acc & eacute;l & eacute;rateur National d'Ions Lourds). Some of the performances of the module are also reported.
|
Hadynska-Klek, K. et al, & Gadea, A. (2013). Towards the determination of superdeformation in Ca-42. Acta Phys. Pol. B, 44(3), 617–625.
Abstract: The Coulomb excitation experiment to study electromagnetic structure of low-lying states in Ca-42 with a focus on a possible superdeformation in this nucleus was performed at the Laboratori Nazionali di Legnaro in Italy. Preliminary values of the determined quadrupole deformation parameters for both the ground state band and the presumed superdeformed band are presented.
|