Bottoni, S., Benzoni, G., Leoni, S., Montanari, D., Bracco, A., Vigezzi, E., et al. (2013). Reaction dynamics and gamma spectroscopy of Ne isotoopes by the heavy ion reaction Ne-22+Pb-208. Acta Phys. Pol. B, 44(3), 457–461.
Abstract: The heavy ion reaction Ne-22+Pb-208 at 128 MeV beam energy has been studied using the PRISMA-CLARA experimental setup at Legnaro National Laboratories. Aim of the experiment is the measurement of elastic, inelastic and one nucleon transfer cross sections. The data are presented in parallel with similar results for the unstable Ne-24 nucleus, using existing data from the reaction Ne-24+Pb-208 at 182 MeV (measured at SPIRAL with the VAMOS-EXOGAM setup). A comparison with angular distributions obtained by semiclassical and DWBA predictions for the quadrupole deformation parameter is also discussed. In particular, the DWBA analysis allowed to determine the beta(C)(2) charge deformation parameter both in Ne-22 and Ne-24.
|
Broda, R. et al, & Gadea, A. (2010). Proton-hole states in the N=30 neutron-rich isotope K-49. Phys. Rev. C, 82(3), 034319–7pp.
Abstract: Excited states in the N = 30 neutron-rich isotope K-49 have been studied using multinucleon transfer reactions with thin targets and the PRISMA-CLARA spectrometer combined with thick-target gamma-coincidence data from Gammasphere. The d(3/2) proton-hole state is located 92 keV above the s(1/2) ground state, and the proton-particle f(7/2) state is suggested at 2104 keV. Three other levels are established as involving the coupling to 2(+) of two neutrons above the N = 28 shell. The measured or estimated lifetimes served to reinforce the interpretation of the observed level structure, which is found to be in satisfactory agreement with shell-model calculations.
|
Caballero, L., Rubio, B., Kleinheinz, P., Yates, S. W., Algora, A., Dewald, A., et al. (2010). Two-phonon octupole excitation in Gd-146. Phys. Rev. C, 81(3), 031301–4pp.
Abstract: Based on experimental evidence from the Sm-144(alpha,2n) reaction, the 3484.7- keV 6(+) state in Gd-146 is identified as the highest-spin member of the 3(-) circle times 3(-) two-phonon octupole quartet. A previously unknown gamma line of 1905.8 keV and E3 character feeding the 3(-) octupole state has been observed. These results represent the first observation of a 6(+) -> 3(-) -> 0(+) cascade of two E3 transitions in an even-even nucleus and provide strong support for the interpretation of the 6(+) state as a two-phonon octupole excitation.
|
Capra, S. et al, & Gadea, A. (2022). GALTRACE: A highly segmented silicon detector array for charged particle spectroscopy and discrimination. Nuovo Cim. C, 45(5), 98–4pp.
Abstract: GALTRACE is an array of segmented silicon detectors specifically built to work as an ancillary of the GALILEO gamma-ray spectrometer at Legnaro National Laboratory of INFN. GALTRACE consists of four telescopic Delta E-Edetectors which allow discriminating light charged particles also via pulse-shape analysis techniques. The good angular and energy resolutions, together with particle discrimination capabilities, make GALTRACE suitable for experiments where coincidences with specific emitted particles allow for the selection of reaction channels with very low cross section. The first in-beam experiment is reported here, aiming at identifying a narrow resonance, near-proton-threshold state in B-11, currently under discussion.
|
Capra, S., Mengoni, D., Dueñas, J. A., John, P. R., Gadea, A., Aliaga, R. J., et al. (2019). Performance of the new integrated front-end electronics of the TRACE array commissioned with an early silicon detector prototype. Nucl. Instrum. Methods Phys. Res. A, 935, 178–184.
Abstract: The spectroscopic performances of the new integrated ASIC (Application-Specific Integrated Circuit) preamplifiers for highly segmented silicon detectors have been evaluated with an early silicon detector prototype of the TRacking Array for light Charged Ejectiles (TRACE). The ASICS were mounted on a custom-designed PCB (Printed Circuit Board) and the detector plugged on it. Energy resolution tests, performed on the same detector before and after irradiation, yielded a resolution of 21 keV and 33 keV FWHM respectively. The output signals were acquired with an array of commercial 100-MHz 14-bit digitizers. The preamplifier chip is equipped with an innovative Fast-Reset device that has two functions: it reduces dramatically the dead time of the preamplifier in case of saturation (from milliseconds to microseconds) and extends the spectroscopic dynamic range of the preamplifier by more than one order of magnitude. Other key points of the device are the low noise and the wide bandwidth.
|