Blanco, A., Belver, D., Cabanelas, P., Diaz, J., Fonte, P., Garzon, J. A., et al. (2012). RPC HADES-TOF wall cosmic ray test performance. Nucl. Instrum. Methods Phys. Res. A, 661, S114–S117.
Abstract: In this work we present results concerning the cosmic ray test, prior to the final installation and commissioning of the new Resistive Plate Chamber (RPC) Time of Flight (TOF) wall for the High-Acceptance DiElectron Spectrometer (HADES) at GSI. The TOF wall is composed of six equal sectors, each one constituted by 186 individual 4-gaps glass-aluminium shielded RPC cells distributed in six columns and 31 rows in two partially overlapping layers, covering an area of 1.26 m(2). All sectors were tested with the final Front End Electronic (FEE) and Data AcQuisition system (DAQ) together with Low Voltage (LV) and High Voltage (HV) systems. Results confirm a very uniform average system time resolution of 77 ps sigma together with an average multi-hit time resolution of 83 ps. Crosstalk levels below 1% (in average), moderate timing tails along with an average longitudinal position resolution of 8.4 mm sigma are also confirmed.
|
|
|
Gil, A., Blanco, A., Castro, E., Diaz, J., Garzon, J. A., Gonzalez-Diaz, D., et al. (2012). The slow control system of the HADES RPC wall. Nucl. Instrum. Methods Phys. Res. A, 661, S118–S120.
Abstract: The control and monitoring system for the new HADES RPC time of flight wall installed at GSI Helmholtzzentrum fur Schwerionenforschung GmbH (Darmstadt, Germany), is described. The slow control system controls/monitors about 6000 variables from different physical devices via a distributed architecture, which uses intensively the 1-wire (R) bus. The software implementation is based on the Experimental Physics and Industrial Control System (EPICS) software tool kit providing low cost, reliability and adaptability without requiring large hardware resources. The control and monitoring system attends five different subsystems: front-end electronics, low voltage, high voltage, gases, and detector. (C) 2010 Elsevier B.V. All rights reserved.
|
|
|
Gil, A., Diaz, J., Gomez-Cadenas, J. J., Herrero, V., Rodriguez, J., Serra, L., et al. (2012). Front-end electronics for accurate energy measurement of double beta decays. Nucl. Instrum. Methods Phys. Res. A, 695, 407–409.
Abstract: NEXT, a double beta decay experiment that will operate in Canfranc Underground Laboratory (Spain), aims at measuring the neutrinoless double-beta decay of the 136Xe isotope using a TPC filled with enriched Xenon gas at high pressure operated in electroluminescence mode. One technological challenge of the experiment is to achieve resolution better than 1% in the energy measurement using a plane of UV sensitive photomultipliers readout with appropriate custom-made front-end electronics. The front-end is designed to be sensitive to the single photo-electron to detect the weak primary scintillation light produced in the chamber, and also to be able to cope with the electroluminescence signal (several hundred times higher and with a duration of microseconds). For efficient primary scintillation detection and precise energy measurement of the electroluminescent signals the front-end electronics features low noise and adequate amplification. The signal shaping provided allows the digitization of the signals at a frequency as low as 40 MHz.
|
|
|
HADES Collaboration(Agakishiev, G. et al), Diaz, J., & Gil, A. (2010). Lambda-p femtoscopy in collisions of Ar + KCl at 1.76AGeV. Phys. Rev. C, 82(2), 021901–5pp.
Abstract: Results on Lambda p femtoscopy are reported at the lowest energy so far. At a beam energy of 1.76AGeV, the reaction Ar + KCl was studied with the High Acceptance Di-Electron Spectrometer ( HADES) at SIS18/GSI. A high-statistics and high-purity Lambda sample was collected, allowing for the investigation of Lambda p correlations at low relative momenta. The experimental correlation function is compared to corresponding model calculations allowing the determination of the space-time extent of the Lambda p emission source. The Lambda p source radius is found to be slightly smaller than the pp correlation radius for a similar collision system. The present Lambda p radius is significantly smaller than that found for Au + Au/Pb + Pb collisions in the AGS, SPS, and RHIC energy domains but larger than that observed for electroproduction from He. Taking into account all available data, we find the Lambda p source radius to increase almost linearly with the number of participants to the power of one-third.
|
|
|
HADES Collaboration(Agakishiev, G. et al), Diaz, J., & Gil, A. (2011). Hyperon production in Ar plus KCl collisions at 1.76A GeV. Eur. Phys. J. A, 47(2), 21–9pp.
Abstract: We present transverse momentum spectra, rapidity distribution and multiplicity of Lambda-hyperons measured with the HADES spectrometer in the reaction Ar(1.76A GeV) + KCl. The yield of Xi(-) is calculated from our previously reported Xi(-)/(Lambda+Sigma(0)) ratio and compared to other strange particle multiplicities. Employing a strangeness balance equation the multiplicities of the yet unmeasured Sigma(+/-)-hyperons can be estimated. Finally a statistical hadronization model is used to fit the yields of pi(-), K+, K-s(0), K-, phi, Lambda and Xi(-). The resulting chemical freeze-out temperature of T = (76 +/- 2) MeV is compared to the measured slope parameters obtained from fits to the transverse mass distributions of the different particles.
|
|