Aydin, S. et al, Gadea, A., & Huyuk, T. (2017). High-spin states and lifetimes in S-33 and shell-model interpretation in the sd-fp space. Phys. Rev. C, 96(2), 024315–10pp.
Abstract: The structure of the S-33 nucleus was investigated in the Mg-24(N-14, alpha p) fusion-evaporation reaction using a 40-MeV N-14 beam. The level scheme was extended up to an excitation energy of 11.7 MeV and spin 19/2+. Lifetimes of the intermediate-and high-spin states have been investigated by the Doppler shift attenuation method. Data were compared with different shell-model calculations where effective interactions involving two main shells, the sd and the fp, are used.
|
|
|
Barrientos, D., Bellato, M., Bazzacco, D., Bortolato, D., Cocconi, P., Gadea, A., et al. (2015). Performance of the Fully Digital FPGA-Based Front-End Electronics for the GALILEO Array. IEEE Trans. Nucl. Sci., 62(6), 3134–3139.
Abstract: In this work we present the architecture and results of a fully digital Front End Electronics (FEE) read out system developed for the GALILEO array. The FEE system, developed in collaboration with the Advanced Gamma Tracking Array (AGATA) collaboration, is composed of three main blocks: preamplifiers, digitizers and preprocessing electronics. The slow control system contains a custom Linux driver, a dynamic library and a server implementing network services. This work presents the first results of the digital FEE system coupled with a GALILEO germanium detector, which has demonstrated the capability to achieve an energy resolution of 1.53% at an energy of 1.33 MeV, similar to the one obtained with a conventional analog system. While keeping a good performance in terms of energy resolution, digital electronics will allow to instrument the full GALILEO array with a versatile system with high integration and low power consumption and costs.
|
|
|
Barrientos, D., Gonzalez, V., Bellato, M., Gadea, A., Bazzacco, D., Blasco, J. M., et al. (2013). Multiple Register Synchronization With a High-Speed Serial Link Using the Aurora Protocol. IEEE Trans. Nucl. Sci., 60(5), 3521–3525.
Abstract: In this work, the development and characterization of a multiple synchronous registers interface communicating with a high-speed serial link and using the Aurora protocol is presented. A detailed description of the developing process and the characterization methods and hardware test benches are also included. This interface will implement the slow control buses of the digitizer cards for the second generation of electronics for the Advanced GAmma Tracking Array (AGATA).
|
|
|
Benzoni, G. et al, Gadea, A., & Algora, A. (2012). First measurement of beta decay half-lives in neutron-rich Tl and Bi isotopes. Phys. Lett. B, 715(4-5), 293–297.
Abstract: Neutron-rich isotopes around lead, beyond N = 126, have been studied exploiting the fragmentation of an uranium primary beam at the FRS-RISING setup at GSI. For the first time beta-decay half-lives of Bi-219 and Tl-211,Tl-212,Tl-213 isotopes have been derived. The half-lives have been extracted using a numerical simulation developed for experiments in high-background conditions. Comparison with state of the art models used in r-process calculations is given, showing a systematic underestimation of the experimental values, at variance from close-lying nuclei.
|
|
|
Bertoldo, S., Maggioni, G., Raniero, W., Carraro, C., Riccetto, S., Sgarbossa, F., et al. (2021). New method for the production of thin and stable, segmented n plus contacts in HPGe detectors. Eur. Phys. J. A, 57(6), 177–10pp.
Abstract: The realization of pulsed-laser diffused, thin n+ contacts on high purity germanium (HPGe) and their successful segmentation is described. The contacts have been obtained by a laser-induced diffusion of Sb atoms, deposited by sputtering on Ge surface, and then segmented by means of a photolithographic technique. Three small prototypes of gamma ray detectors have been implemented, using the same n+ contact (laser diffused Sb) but with three different geometries and a B implanted p+ contact. Electrical and detection properties of the prototypes have been characterized, showing low leakage currents and good spectroscopy data with different gamma-ray sources. The stability of the detector performance has also been tested subjecting one of the prototypes to a typical annealing treatment.
|
|