ATLAS Collaboration(Aad, G. et al), Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., Fernandez Martinez, P., Ferrer, A., et al. (2015). Observation and measurement of Higgs boson decays to WW* with the ATLAS detector. Phys. Rev. D, 92(1), 012006–84pp.
Abstract: We report the observation of Higgs boson decays to WW* based on an excess over background of 6.1 standard deviations in the dilepton final state, where the Standard Model expectation is 5.8 standard deviations. Evidence for the vector-boson fusion (VBF) production process is obtained with a significance of 3.2 standard deviations. The results are obtained from a data sample corresponding to an integrated luminosity of 25 fb(-1) from root s = 7 and 8 TeV pp collisions recorded by the ATLAS detector at the LHC. For a Higgs boson mass of 125.36 GeV, the ratio of the measured value to the expected value of the total production cross section times branching fraction is 1.09(-0.15)(+0.16)(stat)(-0.14)(+0.17)(syst). The corresponding ratios for the gluon fusion and vector-boson fusion production mechanisms are 1.02 +/- 0.19(stat)(-0.18)(+0.22)(syst) and 1.27(-0.40)(+0.44)(stat)(-0.21)(+0.30)(syst), respectively. At root s = 8 TeV, the total production cross sections are measured to be sigma(gg -> H -> WW*) = 4.6 +/- 0.9(stat)(-0.7)(+0.8)(syst) pb and sigma(VBF H -> WW*) = 0.51(-0.15)(+0.17)(stat)(-0.08)(+0.13)(syst) pb. The fiducial cross section is determined for the gluon-fusion process in exclusive final states with zero or one associated jet.
|
ATLAS Collaboration(Aad, G. et al), Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., Fernandez Martinez, P., Ferrer, A., et al. (2015). Search for new phenomena in events with three or more charged leptons in pp collisions at TeV with the ATLAS detector. J. High Energy Phys., 08(8), 138–60pp.
Abstract: A generic search for anomalous production of events with at least three charged leptons is presented. The data sample consists of pp collisions at TeV collected in 2012 by the ATLAS experiment at the CERN Large Hadron Collider, and corresponds to an integrated luminosity of 20.3 fb(-1). Events are required to have at least three selected lepton candidates, at least two of which must be electrons or muons, while the third may be a hadronically decaying tau. Selected events are categorized based on their lepton flavour content and signal regions are constructed using several kinematic variables of interest. No significant deviations from Standard Model predictions are observed. Model-independent upper limits on contributions from beyond the Standard Model phenomena are provided for each signal region, along with prescription to re-interpret the limits for any model. Constraints are also placed on models predicting doubly charged Higgs bosons and excited leptons. For doubly charged Higgs bosons decaying to e tau or μtau, lower limits on the mass are set at 400 GeV at 95% confidence level. For excited leptons, constraints are provided as functions of both the mass of the excited state and the compositeness scale I >, with the strongest mass constraints arising in regions where the mass equals I >. In such scenarios, lower mass limits are set at 3.0 TeV for excited electrons and muons, 2.5 TeV for excited taus, and 1.6 TeV for every excited-neutrino flavour.
|
Briz, J. A., Nerio, A. N., Ballesteros, C., Borge, M. J. G., Martinez, P., Perea, A., et al. (2022). Proton Radiographs Using Position-Sensitive Silicon Detectors and High-Resolution Scintillators. IEEE Trans. Nucl. Sci., 69(4), 696–702.
Abstract: Proton therapy is a cancer treatment technique currently in growth since it offers advantages with respect to conventional X-ray and gamma-ray radiotherapy. In particular, better control of the dose deposition allowing to reach higher conformity in the treatments causing less secondary effects. However, in order to take full advantage of its potential, improvements in treatment planning and dose verification are required. A new prototype of proton computed tomography scanner is proposed to design more accurate and precise treatment plans for proton therapy. Our prototype is formed by double-sided silicon strip detectors and scintillators of LaBr3(Ce) with high energy resolution and fast response. Here, the results obtained from an experiment performed using a 100-MeV proton beam are presented. Proton radiographs of polymethyl methacrylate (PMMA) samples of 50-mm thickness with spatial patterns in aluminum were taken. Their properties were studied, including reproduction of the dimensions, spatial resolution, and sensitivity to different materials. Structures of up to 2 mm are well resolved and the sensitivity of the system was enough to distinguish the thicknesses of 10 mm of aluminum or PMMA. The spatial resolution of the images was 0.3 line pairs per mm (MTF-10%). This constitutes the first step to validate the device as a proton radiography scanner.
|