|
Records |
Links |
|
Author ![sorted by Author field, ascending order (up)](img/sort_asc.gif) |
SuperNEMO Collaboration (Argyriades, J. et al); Carcel, S.; Diaz, J.; Monrabal, F.; Serra, L.; Yahlali, N. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title |
Results of the BiPo-1 prototype for radiopurity measurements for the SuperNEMO double beta decay source foils |
Type |
Journal Article |
|
Year |
2010 |
Publication |
Nuclear Instruments & Methods in Physics Research A |
Abbreviated Journal |
Nucl. Instrum. Methods Phys. Res. A |
|
|
Volume |
622 |
Issue |
1 |
Pages |
120-128 |
|
|
Keywords |
Double beta decay; NEMO-3; SuperNEMO; BiPo; Majorana neutrino; Radiopurity |
|
|
Abstract |
The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in (TI)-T-208 and Bi-214 for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 m(2) of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-1 is to measure the different components of the background and in particular the surface radiopurity of the plastic scintillators that make up the detector. The first phase of data collection has been dedicated to the measurement of the radiopurity in (TI)-T-208. After more than one year of background measurement, a surface activity of the scintillators of A((TI)-T-208) = 1.5 μBq/m(2) is reported here. Given this level of background, a larger BiPo detector having 12 m(2) of active surface area, is able to qualify the radiopurity of the SuperNEMO selenium double beta decay foils with the required sensitivity of A((TI)-T-208) <2 μBq/kg (90% CL.) with a six month measurement. |
|
|
Address |
[Argyriades, J.; Augier, C.; Bongrand, M.; Bourgeois, C.; Breton, D.; Briere, M.; Broudin-Bay, G.; Garrido, X.; Jenzer, S.; Jullian, S.; Sarazin, X.; Simard, L.; Szklarz, G.] Univ Paris 11, LAL, CNRS, IN2P3, F-91405 Orsay, France, Email: sarazin@lal.in2p3.fr |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0168-9002 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
ISI:000282530300016 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ elepoucu @ |
Serial |
364 |
|
Permanent link to this record |
|
|
|
|
Author ![sorted by Author field, ascending order (up)](img/sort_asc.gif) |
SuperNEMO Collaboration (Arnold, R. et al); Diaz, J.; Monrabal, F.; Serra, L.; Yahlali, N. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title |
Probing new physics models of neutrinoless double beta decay with SuperNEMO |
Type |
Journal Article |
|
Year |
2010 |
Publication |
European Physical Journal C |
Abbreviated Journal |
Eur. Phys. J. C |
|
|
Volume |
70 |
Issue |
4 |
Pages |
927-943 |
|
|
Keywords |
|
|
|
Abstract |
The possibility to probe new physics scenarios of light Majorana neutrino exchange and right-handed currents at the planned next generation neutrinoless double beta decay experiment SuperNEMO is discussed. Its ability to study different isotopes and track the outgoing electrons provides the means to discriminate different underlying mechanisms for the neutrinoless double beta decay by measuring the decay half-life and the electron angular and energy distributions. |
|
|
Address |
[Arnold, R.; Kovalenko, V.] Univ Strasbourg, IPHC, CNRS, IN2P3, F-67037 Strasbourg, France, Email: frank.deppisch@manchester.ac.uk |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1434-6044 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
ISI:000285208000003 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ elepoucu @ |
Serial |
308 |
|
Permanent link to this record |
|
|
|
|
Author ![sorted by Author field, ascending order (up)](img/sort_asc.gif) |
Taoso, M.; Iocco, F.; Meynet, G.; Bertone, G.; Eggenberger, P. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title |
Effect of low mass dark matter particles on the Sun |
Type |
Journal Article |
|
Year |
2010 |
Publication |
Physical Review D |
Abbreviated Journal |
Phys. Rev. D |
|
|
Volume |
82 |
Issue |
8 |
Pages |
083509 - 14pp |
|
|
Keywords |
|
|
|
Abstract |
We study the effect of dark matter (DM) particles in the Sun, focusing, in particular, on the possible reduction of the solar neutrinos flux due to the energy carried away by DM particles from the innermost regions of the Sun, and to the consequent reduction of the temperature of the solar core. We find that in the very low-mass range between 4 and 10 GeV, recently advocated to explain the findings of the DAMA and CoGent experiments, the effects on neutrino fluxes are detectable only for DM models with a very small, or vanishing, self-annihilation cross section, such as the so-called asymmetric DM models, and we study the combination of DM masses and spin-dependent cross sections which can be excluded with current solar neutrino data. Finally, we revisit the recent claim that DM models with large self-interacting cross sections can lead to a modification of the position of the convective zone, alleviating or solving the solar composition problem. We show that when the "geometric'' upper limit on the capture rate is correctly taken into account, the effects of DM are reduced by orders of magnitude, and the position of the convective zone remains unchanged. |
|
|
Address |
[Taoso, Marco] Univ Valencia, CSIC, IFIC, Ed Inst, Valencia 46071, Spain |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Amer Physical Soc |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1550-7998 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
ISI:000282680900002 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ elepoucu @ |
Serial |
369 |
|
Permanent link to this record |
|
|
|
|
Author ![sorted by Author field, ascending order (up)](img/sort_asc.gif) |
TAPS Collaboration; Piasecki, K.; Matulewicz, T.; Yahlali, N.; Delagrange, H.; Diaz, J.; d'Enterria, D.G.; Fernandez, F.; Kugler, A.; Lohner, H.; Martinez-Garcia, G.; Ostendorf, R.W.; Schutz, Y.; Tlusty, P.; Turrisi, R.; Wagner, V.; Wilschut, H.W. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title |
Emission patterns of neutral pions in 40A MeV Ta plus Au reactions |
Type |
Journal Article |
|
Year |
2010 |
Publication |
Physical Review C |
Abbreviated Journal |
Phys. Rev. C |
|
|
Volume |
81 |
Issue |
5 |
Pages |
054912 - 7pp |
|
|
Keywords |
|
|
|
Abstract |
Differential cross sections of neutral pions emitted in Ta-181+Au-197 collisions at a beam energy of 39.5A Me V have been measured with the two-arm photon spectrometer (TAPS). The kinetic energy and transverse momentum spectra of neutral pions cannot be properly described in the framework of the thermal model, nor when the reabsorption of pions is accounted for in a phenomenological model. However, high energy and high momentum tails of the pion spectra can be well fitted through thermal distributions with unexpectedly soft temperature parameters below 10 MeV. |
|
|
Address |
[Piasecki, K.; Matulewicz, T.] Univ Warsaw, Inst Expt Phys, PL-00681 Warsaw, Poland, Email: Krzysztof.Piasecki@fuw.edu.pl |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Amer Physical Soc |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0556-2813 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
ISI:000278144800055 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ elepoucu @ |
Serial |
442 |
|
Permanent link to this record |
|
|
|
|
Author ![sorted by Author field, ascending order (up)](img/sort_asc.gif) |
Tetrault, M.A.; Oliver, J.F.; Bergeron, M.; Lecomte, R.; Fontaine, R. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Real Time Coincidence Detection Engine for High Count Rate Timestamp Based PET |
Type |
Journal Article |
|
Year |
2010 |
Publication |
IEEE Transactions on Nuclear Science |
Abbreviated Journal |
IEEE Trans. Nucl. Sci. |
|
|
Volume |
57 |
Issue |
1 |
Pages |
117-124 |
|
|
Keywords |
Coincidence detection; Positron Emission Tomography (PET) |
|
|
Abstract |
Coincidence engines follow two main implementation flows: timestamp based systems and AND-gate based systems. The latter have been more widespread in recent years because of its lower cost and high efficiency. However, they are highly dependent on the selected electronic components, they have limited flexibility once assembled and they are customized to fit a specific scanner's geometry. Timestamp based systems are gathering more attention lately, especially with high channel count fully digital systems. These new systems must however cope with important singles count rates. One option is to record every detected event and postpone coincidence detection offline. For daily use systems, a real time engine is preferable because it dramatically reduces data volume and hence image preprocessing time and raw data management. This paper presents the timestamp based coincidence engine for the LabPET(TM), a small animal PET scanner with up to 4608 individual readout avalanche photodiode channels. The engine can handle up to 100 million single events per second and has extensive flexibility because it resides in programmable logic devices. It can be adapted for any detector geometry or channel count, can be ported to newer, faster programmable devices and can have extra modules added to take advantage of scanner-specific features. Finally, the user can select between full processing mode for imaging protocols and minimum processing mode to study different approaches for coincidence detection with offline software. |
|
|
Address |
[Tetrault, M. -A.; Fontaine, R.] Univ Sherbrooke, Dept Elect & Comp Engn, Sherbrooke, PQ J1K 2R1, Canada, Email: Marc-Andre.Tetrault@USherbrooke.ca |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Ieee-Inst Electrical Electronics Engineers Inc |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0018-9499 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
ISI:000274391000016 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ elepoucu @ |
Serial |
500 |
|
Permanent link to this record |