Staub, F., Athron, P., Basso, L., Goodsell, M. D., Harries, D., Krauss, M. E., et al. (2016). Precision tools and models to narrow in on the 750 GeV diphoton resonance. Eur. Phys. J. C, 76(9), 516–57pp.
Abstract: The hints for a new resonance at 750 GeV from ATLAS and CMS have triggered a significant amount of attention. Since the simplest extensions of the standard model cannot accommodate the observation, many alternatives have been considered to explain the excess. Here we focus on several proposed renormalisable weakly-coupled models and revisit results given in the literature. We point out that physically important subtleties are often missed or neglected. To facilitate the study of the excess we have created a collection of 40 model files, selected from recent literature, for the Mathematica package SARAH. With SARAH one can generate files to perform numerical studies using the tailor-made spectrum generators FlexibleSUSY and SPheno. These have been extended to automatically include crucial higher order corrections to the diphoton and digluon decay rates for both CP-even and CP-odd scalars. Additionally, we have extended the UFO and CalcHep interfaces of SARAH, to pass the precise information about the effective vertices from the spectrum generator to a Monte-Carlo tool. Finally, as an example to demonstrate the power of the entire setup, we present a new supersymmetric model that accommodates the diphoton excess, explicitly demonstrating how a large width can be obtained. We explicitly show several steps in detail to elucidate the use of these public tools in the precision study of this model.
|
Song, N. Q., Garcia, R. B., Gomez-Cadenas, J. J., Gonzalez-Garcia, M. C., Conde, A. P., & Taron, J. (2016). Conditions for statistical determination of the neutrino mass spectrum in radiative emission of neutrino pairs in atoms. Phys. Rev. D, 93(1), 013020–10pp.
Abstract: The photon spectrum in macrocoherent atomic deexcitation via radiative emission of neutrino pairs has been proposed as a sensitive probe of the neutrino mass spectrum, capable of competing with conventional neutrino experiments. In this paper we revisit this interesting proposal in order to quantify the requirements for statistical determination of some of the properties of the neutrino spectrum, in particular, the neutrino mass scale and the mass ordering. Our results are shown as the product of the experimental lifetime, the target volume, and the number density of atoms which have to be set in a coherence state with a given electric field in the target, needed for determination of these properties with a given confidence level.
|
Solevi, P., Muñoz, E., Solaz, C., Trovato, M., Dendooven, P., Gillam, J. E., et al. (2016). Performance of MACACO Compton telescope for ion-beam therapy monitoring: first test with proton beams. Phys. Med. Biol., 61(14), 5149–5165.
Abstract: In order to exploit the advantages of ion-beam therapy in a clinical setting, delivery verification techniques are necessary to detect deviations from the planned treatment. Efforts are currently oriented towards the development of devices for real-time range monitoring. Among the different detector concepts proposed, Compton cameras are employed to detect prompt gammas and represent a valid candidate for real-time range verification. We present the first on-beam test of MACACO, a Compton telescope (multi-layer Compton camera) based on lanthanum bromide crystals and silicon photo-multipliers. The Compton telescope was first characterized through measurements and Monte Carlo simulations. The detector linearity was measured employing Na-22 and Am-Be sources, obtaining about 10% deviation from linearity at 3.44 MeV. A spectral image reconstruction algorithm was tested on synthetic data. Point-like sources emitting gamma rays with energy between 2 and 7 MeV were reconstructed with 3-5 mm resolution. The two-layer Compton telescope was employed to measure radiation emitted from a beam of 150 MeV protons impinging on a cylindrical PMMA target. Bragg-peak shifts were achieved via adjustment of the PMMA target location and the resulting measurements used during image reconstruction. Reconstructed Bragg peak profiles proved sufficient to observe peak-location differences within 10 mm demonstrating the potential of the MACACO Compton Telescope as a monitoring device for ion-beam therapy.
|
Serenelli, A., Scott, P., Villante, F. L., Vincent, A. C., Asplund, M., Basu, S., et al. (2016). Implications of solar wind measurements for solar models and composition. Mon. Not. Roy. Astron. Soc., 463(1), 2–9.
Abstract: We critically examine recent claims of a high solar metallicity by von Steiger & Zurbuchen (2016, vSZ16) based onin situ measurements of the solar wind, rather than the standard spectroscopically inferred abundances (Asplund et al. 2009, hereafter AGSS09). We test the claim by Vagnozzi et al. (2016) that a composition based on the solar wind enables one to construct a standard solar model in agreement with helioseismological observations and thus solve the decades-old solar modelling problem. We show that, although some helioseismological observables are improved compared to models computed with spectroscopic abundances, most are in fact worse. The high abundance of refractory elements leads to an overproduction of neutrinos, with a predicted B-8 flux that is nearly twice its observed value, and Be-7 and CNO fluxes that are experimentally ruled out at high confidence. A combined likelihood analysis shows that models using the vSZ16 abundances are worse than AGSS09 despite a higher metallicity. We also present astrophysical and spectroscopic arguments showing the vSZ16 composition to be an implausible representation of the solar interior, identifying the first ionization potential effect in the outer solar atmosphere and wind as the likely culprit.
|
Sekihara, T., Oset, E., & Ramos, A. (2016). On the structure observed in the in-flight He-3(K-, Lambda p)n reaction at J-PARC. Prog. Theor. Exp. Phys., 2016(12), 123D03–27pp.
Abstract: A theoretical investigation is done to clarify the origin of the peak structure observed near the K-pp threshold in the in-flight He-3(K-, Lambda p)n reaction of the J-PARC E15 experiment, which could be a signal of the lightest kaonic nuclei, i.e., the (K) over bar NN (I = 1/2) state. For the investigation, we evaluate the Lambda p invariant mass spectrum assuming two possible scenarios to interpret the experimental peak. One assumes that the Lambda (1405) resonance is generated after the emission of an energetic neutron from the absorption of the initial K-, not forming a bound state with the remaining proton. This uncorrelated Lambda (1405)p system subsequently decays into the final Lambda p. The other scenario implies that, after the emission of the energetic neutron, a (K) over bar NN bound state is formed, decaying eventually into a Lambda p pair. Our results show that the experimental signal observed in the in-flight He-3(K-, Lambda p)n reaction at J-PARC is qualitatively well reproduced by the assumption that a (K) over bar NN bound state is generated in the reaction, definitely discarding the interpretation in terms of an uncorrelated Lambda (1405)p s tate.
|