|   | 
Details
   web
Records
Author (down) Sanchis-Lozano, M.A.
Title Stringy Signals from Large-Angle Correlations in the Cosmic Microwave Background? Type Journal Article
Year 2022 Publication Universe Abbreviated Journal Universe
Volume 8 Issue 8 Pages 396 - 13pp
Keywords cosmic microwave background; angular correlations; inflation; string theory
Abstract We interpret the lack of large-angle temperature correlations and the even-odd parity imbalance observed in the cosmic microwave background (CMB) by COBE, WMAP and Planck satellite missions as a possible stringy signal ultimately stemming from a composite inflaton field (e.g., a fermionic condensate). Based on causality arguments and a Fourier analysis of the angular two-point correlation function, two infrared cutoffs k(min)(even,odd) (satisfying k(min)(even) similar or equal to 2k(min)(odd)) are introduced to the CMB power spectrum associated, respectively, with periodic and antiperiodic boundary conditions of the fermionic constituents (echoing the Neveu-Schwarz-Ramond model in superstring theory), without resorting to any particular model.
Address [Sanchis-Lozano, Miguel-Angel] Univ Valencia, Dept Theoret Phys, Doctor Moliner 50, Burjassot 46011, Spain, Email: miguel.angel.sanchis@ific.uv.es
Corporate Author Thesis
Publisher Mdpi Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN ISBN Medium
Area Expedition Conference
Notes WOS:000845107300001 Approved no
Is ISI yes International Collaboration no
Call Number IFIC @ pastor @ Serial 5344
Permanent link to this record
 

 
Author (down) Roser, J.; Barrientos, L.; Bernabeu, J.; Borja-Lloret, M.; Muñoz, E.; Ros, A.; Viegas, R.; Llosa, G.
Title Joint image reconstruction algorithm in Compton cameras Type Journal Article
Year 2022 Publication Physics in Medicine and Biology Abbreviated Journal Phys. Med. Biol.
Volume 67 Issue 15 Pages 155009 - 15pp
Keywords Compton camera; compton imaging; hadron therapy; image reconstruction; LM-MLEM; Monte Carlo simulations; multi-layer compton telescope
Abstract Objective. To demonstrate the benefits of using an joint image reconstruction algorithm based on the List Mode Maximum Likelihood Expectation Maximization that combines events measured in different channels of information of a Compton camera. Approach. Both simulations and experimental data are employed to show the algorithm performance. Main results. The obtained joint images present improved image quality and yield better estimates of displacements of high-energy gamma-ray emitting sources. The algorithm also provides images that are more stable than any individual channel against the noisy convergence that characterizes Maximum Likelihood based algorithms. Significance. The joint reconstruction algorithm can improve the quality and robustness of Compton camera images. It also has high versatility, as it can be easily adapted to any Compton camera geometry. It is thus expected to represent an important step in the optimization of Compton camera imaging.
Address [Roser, J.; Barrientos, L.; Bernabeu, J.; Borja-Lloret, M.; Munoz, E.; Ros, A.; Viegas, R.; Llosa, G.] CSIC UV, Inst Fis Corpuscular IFIC, Valencia, Spain, Email: Jorge.Roser@ific.uv.es
Corporate Author Thesis
Publisher IOP Publishing Ltd Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0031-9155 ISBN Medium
Area Expedition Conference
Notes WOS:000827830200001 Approved no
Is ISI yes International Collaboration no
Call Number IFIC @ pastor @ Serial 5298
Permanent link to this record
 

 
Author (down) Romero-Barrientos, J.; Marquez Damian, J.I.; Molina, F.; Zambra, M.; Aguilera, P.; Lopez-Usquiano, F.; Parra, B.; Ruiz, A.
Title Calculation of kinetic parameters beta eff and L with modified open source Monte Carlo code OpenMC(TD) Type Journal Article
Year 2022 Publication Nuclear Engineering and Technology Abbreviated Journal Nucl. Eng. Technol.
Volume 54 Issue 3 Pages 811-816
Keywords OpenMC; Monte Carlo; Kinetic parameters; Open source; Neutron generation time; Effective delayed neutron fraction
Abstract This work presents the methodology used to expand the capabilities of the Monte Carlo code OpenMC for the calculation of reactor kinetic parameters: effective delayed neutron fraction beff and neutron generation time L. The modified code, OpenMC(Time-Dependent) or OpenMC(TD), was then used to calculate the effective delayed neutron fraction by using the prompt method, while the neutron generation time was estimated using the pulsed method, fitting L to the decay of the neutron population. OpenMC(TD) is intended to serve as an alternative for the estimation of kinetic parameters when licensed codes are not available. The results obtained are compared to experimental data and MCNP calculated values for 18 benchmark configurations.
Address [Romero-Barrientos, J.; Molina, F.; Zambra, M.; Aguilera, P.; Lopez-Usquiano, F.; Ruiz, A.] Comis Chilena Energia Nucl, Santiago 12501, Chile, Email: romeroj@uchile.cl
Corporate Author Thesis
Publisher Korean Nuclear Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1738-5733 ISBN Medium
Area Expedition Conference
Notes WOS:000766649800004 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 5172
Permanent link to this record
 

 
Author (down) Rodas, A.; Pilloni, A.; Albaladejo, M.; Fernandez-Ramirez, C.; Mathieu, V.; Szczepaniak, A.P.
Title Scalar and tensor resonances in J/psi radiative decays Type Journal Article
Year 2022 Publication European Physical Journal C Abbreviated Journal Eur. Phys. J. C
Volume 82 Issue 1 Pages 80 - 17pp
Keywords
Abstract We perform a systematic analysis of the J/psi -> gamma pi(0)pi(0) and -> gamma(KSKS0)-K-0 partial waves measured by BESIII. We use a large set of amplitude parametrizations to reduce the model bias. We determine the physical properties of seven scalar and tensor resonances in the 1-2.5 GeV mass range. These include the well known f(0)(1500) and f(0)(1710), that are considered to be the primary glueball candidates. The hierarchy of resonance couplings determined from this analysis favors the latter as the one with the largest glueball component.
Address [Rodas, A.] Coll William & Mary, Dept Phys, Williamsburg, VA 23187 USA, Email: arodas@wm.edu;
Corporate Author Thesis
Publisher Springer Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1434-6044 ISBN Medium
Area Expedition Conference
Notes WOS:000749246700011 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 5102
Permanent link to this record
 

 
Author (down) Roca, L.; Liang, W.H.; Oset, E.
Title Inconsistency of the data on the K-1(1270) -> pi K-0*(1430) decay width Type Journal Article
Year 2022 Publication Physics Letters B Abbreviated Journal Phys. Lett. B
Volume 824 Issue Pages 136827 - 3pp
Keywords
Abstract We show, using the same Lagrangian for the K-1(1270) -> pi K-0*(1430) and K-0*(1430) -> K-1 (1270)pi decays, that the present PDG data on the partial decay width of K-1 (1270) -> pi K-0*(1430) implies a width for K-0*(1430) -> K-1 (1270)pi decay which is about one order of magnitude larger than the total K-0*(1430) width. A discussion on this inconsistency is done, stressing its relationship to the existence of two K-1(1270) states obtained with the chiral unitary theory, which are not considered in the experimental analyses of K pi pi data.
Address [Roca, L.] Univ Murcia, Dept Fis, E-30071 Murcia, Spain, Email: luisroca@um.es;
Corporate Author Thesis
Publisher Elsevier Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0370-2693 ISBN Medium
Area Expedition Conference
Notes WOS:000734123200006 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 5061
Permanent link to this record