Mengoni, D., Duenas, J. A., Assie, M., Boiano, C., John, P. R., Aliaga, R. J., et al. (2014). Digital pulse-shape analysis with a TRACE early silicon prototype. Nucl. Instrum. Methods Phys. Res. A, 764, 241–246.
Abstract: A highly segmented silicon-pad detector prototype has been tested to explore the performance of the digital pulse shape analysis in the discrimination of the particles reaching the silicon detector. For the first time a 200 tun thin silicon detector, grown using an ordinary floating zone technique, has been shown to exhibit a level discrimination thanks to the fine segmentation. Light-charged particles down to few MeV have been separated, including their punch-through. A coaxial HPGe detector in time coincidence has further confirmed the quality of the particle discrimination.
|
Mijatovia, T., Szilner, S., Corradi, L., Montanari, D., Pollarolo, G., Fioretto, E., et al. (2016). Study of the cross section determination with the PRISMA spectrometer: The Ar-40+Pb-208 case. Eur. Phys. J. A, 52(4), 113–6pp.
Abstract: The PRISMA spectrometer's response function was successfully applied to match three angular and magnetic settings over a wide angular range for measurements of quasi-elastic reactions in Ar-40 + Pb-208 . The absolute scale of cross sections has been obtained by using the Rutherford cross section at the forward angles and the information from the energy distributions measured with the spectrometer without and with coincidences with the CLARA -array. The semi-classical model GRAZING has been used to test the unfolding procedure and for comparison with the corrected cross sections.
|
Mijatovic, T., Szilner, S., Corradi, L., Montanari, D., Courtin, S., Fioretto, E., et al. (2015). Pairing Correlation Study in the 40Ar + 208Pb Multinucleon Transfer Reaction. Acta Phys. Pol. B, 46(3), 439–442.
Abstract: The Ar-40 + Pb-208 multinucleon transfer reaction has been studied at E-lab = 255 MeV with the large solid angle magnetic spectrometer PRISMA. Mass and charge yields, differential and total cross sections, total kinetic energy loss distributions of different channels were simultaneously measured. Angular distributions were measured in a wide angular range by matching different spectrometer angular settings. Absolute cross sections were obtained by careful evaluation of the spectrometer response function. These cross sections for different transfer channels allow the discussion of the role played by nucleon-nucleon correlations.
|
Mijatovic, T., Szilner, S., Corradi, L., Montanari, D., Pollarolo, G., Fioretto, E., et al. (2016). Multinucleon transfer reactions in the Ar-40+Pb-208 system. Phys. Rev. C, 94(6), 064616–7pp.
Abstract: We measured multinucleon transfer reactions in the Ar-40 + Pb-208 system at an energy close to the Coulomb barrier, by employing the PRISMA magnetic spectrometer. We extracted differential and total cross sections of the different transfer channels, with a careful investigation of the total kinetic energy loss distributions. Comparisons between different systems having the same Pb-208 target and with projectiles going from neutron-poor to neutron-rich nuclei, i.e., Ca-40, Ni-58, and Ar-40, as well as between the data and GRAZING calculations have been carried out. The neutron-rich (stable) Ar-40 beam allowed us to get access to the channels involving proton pickup, whose behavior in connection with the production of neutron-rich heavy partner has been outlined.
|
Modamio, V., Valiente-Dobon, J. J., Jaworski, G., Huyuk, T., Triossi, A., Egea, J., et al. (2015). Digital pulse-timing technique for the neutron detector array NEDA. Nucl. Instrum. Methods Phys. Res. A, 775, 71–76.
Abstract: A new digital pulse-timing algorithm, to be used with the future neutron detector array NEDA, has been developed and tested. The time resolution of four 5 in diameter photomultiplier tubes (XP4512, R4144, R11833-100, and ET9390-kb), coupled to a cylindrical 5 in by 5 in BC501A liquict scintillator detector was measured by employing digital sampling electronics and a constant fraction discriminator (CFD) algorithm. The zero crossing of the CM algorithm was obtained with a cubic spline interpolation, which was continuous up to the second derivative. The performance of the algorithm was studied at sampling rates of 500 MS/s and 200 MS/s. The time resolution obtained with the digital electronics was compared to the values acquired with a standard analog CFD. The result of this comparison shows that the time resolution from the analog and the digital measurements at 500 MS/s and at 200 MS/s are within 15% for all the tested photomultiplier tubes.
|