n_TOF Collaboration(Mingrone, F. et al), Domingo-Pardo, C., Giubrone, G., & Tain, J. L. (2017). Neutron capture cross section measurement of U-238 at the CERN n_TOF facility in the energy region from 1 eV to 700 keV. Phys. Rev. C, 95(3), 034604–14pp.
Abstract: The aim of this work is to provide a precise and accurate measurement of the U-238(n,gamma) reaction cross section in the energy region from 1 eV to 700 keV. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behavior of the reactor core. In particular, fast reactors, which are experiencing a growing interest for their ability to burn radioactive waste, operate in the high energy region of the neutron spectrum. In this energy region most recent evaluations disagree due to inconsistencies in the existing measurements of up to 15%. In addition, the assessment of nuclear data uncertainty performed for innovative reactor systems shows that the uncertainty in the radiative capture cross section of U-238 should be further reduced to 1-3% in the energy region from 20 eV to 25 keV. To this purpose, addressed by the Nuclear Energy Agency as a priority nuclear data need, complementary experiments, one at the GELINA and two at the nTOF facility, were proposed and carried out within the 7th Framework Project ANDES of the European Commission. The results of one of these U-238(n, gamma) measurements performed at the nTOF CERN facility are presented in this work. The gamma-ray cascade following the radiative neutron capture has been detected exploiting a setup of two C6D6 liquid scintillators. Resonance parameters obtained from this work are on average in excellent agreement with the ones reported in evaluated libraries. In the unresolved resonance region, this work yields a cross section in agreement with evaluated libraries up to 80 keV, while for higher energies our results are significantly higher.
|
|
|
n_TOF Collaboration(Michalopoulou, V. et al), Babiano-Suarez, V., Caballero, L., Domingo-Pardo, C., Ladarescu, I., & Tain, J. L. (2023). Measurement of the neutron-induced fission cross section of Th-230 at the CERN n_TOF facility. Phys. Rev. C, 108(1), 014616–15pp.
Abstract: The neutron-induced fission cross section of Th-230 has been measured at the neutron time-of-flight facility n_TOF located at CERN. The experiment was performed at the experimental area EAR-1 with a neutron flight path of 185 m, using Micromegas detectors for the detection of the fission fragments. The Th-230(n, f ) cross section was determined relative to the U-235(n, f ) one, covering the energy range from the fission threshold up to 400 MeV. The results from the present work are compared with existing cross-section datasets and the observed discrepancies are discussed and analyzed. Finally, using the code EMPIRE 3.2.3 a theoretical study, based on the statistical model, was performed leading to a satisfactory reproduction of the experimental results with the proper tuning of the respective parameters, while for incident neutron energy beyond 200 MeV the fission of( 230)Th was described by Monte Carlo simulations.
|
|
|
n_TOF Collaboration(Mendoza, E. et al), Giubrone, G., Tain, J. L., & Tarifeño-Saldivia, A. (2018). Measurement and analysis of the Am-241 neutron capture cross section at the n_TOF facility at CERN. Phys. Rev. C, 97(5), 054616–21pp.
Abstract: The Am-241(n, gamma) cross section has been measured at the nTOF facility at CERN with the nTOF BaF2 Total Absorption Calorimeter in the energy range between 0.2 eV and 10 keV. Our results are analyzed as resolved resonances up to 700 eV, allowing a more detailed description of the cross section than in the current evaluations, which contain resolved resonances only up to 150-160 eV. The cross section in the unresolved resonance region is perfectly consistent with the predictions based on the average resonance parameters deduced from the resolved resonances, thus obtaining a consistent description of the cross section in the full neutron energy range under study. Below 20 eV, our results are in reasonable agreement with JEFF-3.2 as well as with the most recent direct measurements of the resonance integral, and differ up to 20-30% with other experimental data. Between 20 eV and 1 keV, the disagreement with other experimental data and evaluations gradually decreases, in general, with the neutron energy. Above 1 keV, we find compatible results with previously existing values.
|
|
|
n_TOF Collaboration(Mendoza, E. et al), Domingo-Pardo, C., & Tain, J. L. (2014). Measurement and analysis of the Am-243 neutron capture cross section at the n_TOF facility at CERN. Phys. Rev. C, 90(3), 034608–16pp.
Abstract: Background: The design of new nuclear reactors and transmutation devices requires to reduce the present neutron cross section uncertainties of minor actinides. Purpose: Improvement of the Am-243(n, gamma) cross section uncertainty. Method: The Am-243(n, gamma) cross section has been measured at the n_TOF facility at CERN with a BaF2 total absorption calorimeter, in the energy range between 0.7 eV and 2.5 keV. Results: The Am-243(n, gamma) cross section has been successfully measured in the mentioned energy range. The resolved resonance region has been extended from 250 eV up to 400 eV. In the unresolved resonance region our results are compatible with one of the two incompatible capture data sets available below 2.5 keV. The data available in EXFOR and in the literature have been used to perform a simple analysis above 2.5 keV. Conclusions: The results of this measurement contribute to reduce the Am-243(n, gamma) cross section uncertainty and suggest that this cross section is underestimated up to 25% in the neutron energy range between 50 eV and a few keV in the present evaluated data libraries.
|
|
|
n_TOF Collaboration(Massimi, C. et al), Domingo-Pardo, C., & Tain, J. L. (2010). Au-197(n,gamma) cross section in the resonance region. Phys. Rev. C, 81(4), 044616–22pp.
Abstract: The (n,gamma) cross section of Au-197 has been measured at nTOF in the resolved resonance region, up to 5 keV, with the aim of improving the accuracy in an energy range where it is not yet considered standard. The measurements were performed with two different experimental setup and detection techniques, the total energy method based on C6D6 detectors, and the total absorption calorimetry based on a 4 pi BaF2 array. By comparing the data collected with the two techniques, two accurate sets of neutron-capture yields have been obtained, which could be the basis for a new evaluation leading to an extended cross-section standard. Overall good agreement is found between the n_TOF results and evaluated cross sections, with some significant exceptions for small resonances. A few resonances not included in the existing databases have also been observed.
|
|