Bottoni, S., Benzoni, G., Leoni, S., Montanari, D., Bracco, A., Vigezzi, E., et al. (2013). Reaction dynamics and gamma spectroscopy of Ne isotoopes by the heavy ion reaction Ne-22+Pb-208. Acta Phys. Pol. B, 44(3), 457–461.
Abstract: The heavy ion reaction Ne-22+Pb-208 at 128 MeV beam energy has been studied using the PRISMA-CLARA experimental setup at Legnaro National Laboratories. Aim of the experiment is the measurement of elastic, inelastic and one nucleon transfer cross sections. The data are presented in parallel with similar results for the unstable Ne-24 nucleus, using existing data from the reaction Ne-24+Pb-208 at 182 MeV (measured at SPIRAL with the VAMOS-EXOGAM setup). A comparison with angular distributions obtained by semiclassical and DWBA predictions for the quadrupole deformation parameter is also discussed. In particular, the DWBA analysis allowed to determine the beta(C)(2) charge deformation parameter both in Ne-22 and Ne-24.
|
|
|
Corradi, L., Szilner, S., Pollarolo, G., Colo, G., Mason, P., Farnea, E., et al. (2011). Single and pair neutron transfers at sub-barrier energies. Phys. Rev. C, 84(3), 034603–10pp.
Abstract: Multinucleon transfer cross sections in the (96)Zr+(40)Ca system have been measured, in inverse kinematics, at bombarding energies ranging from the Coulomb barrier to similar to 25% below. Targetlike recoils have been identified in A, Z and velocity with the large solid angle magnetic spectrometer PRISMA. The experimental data for one- and two-neutron transfer channels have been compared with semiclassical microscopic calculations. For the two-neutron transfer channels the relevance of the transitions to the ground state and to the 0(+) excited states of (42)Ca are discussed by employing, for the reaction mechanism, the successive approximation. It is found that the transition to the 0(+) state at similar to 6 MeV, whose wave function is dominated by the two neutrons in the 2p(3/2) shell, is much larger than the ground state one. The comparison with the inclusive data reveals that transitions to states with high multipolarity and non-natural parity are important. This suggests that more complex two-particle correlations have to be incorporated in the treatment of the transfer process.
|
|
|
Doncel, M., Cederwall, B., Martin, S., Quintana, B., Gadea, A., Farnea, E., et al. (2015). Conceptual design of a high resolution Ge array with tracking and imaging capabilities for the DESPEC (FAIR) experiment. J. Instrum., 10, P06010–15pp.
Abstract: We present results of Monte Carlo simulations for the conceptual design of the high-resolution DESPEC Germanium Array Spectrometer (DEGAS) proposed for the Facility for Ion and Antiproton Research (FAIR) under construction at Darmstadt, Germany. The project is carried out in three phases, although only results for the two first phases will be addressed in this work. The first phase will consist of a re-arrangement of the EUROBALL cluster detectors previously used in the RISING campaign at GSI. The second phase is based on coupling AGATA-type triple-cluster detectors with EUROBALL cluster detectors in a compact geometry around the active ion implantation target of DESPEC.
|
|
|
Goasduff, A., Valiente-Dobon, J. J., Lunardi, S., Haas, F., Gadea, A., de Angelis, G., et al. (2014). Counting rate measurements for lifetime experiments using the RDDS method with the new generation gamma-ray array AGATA. Nucl. Instrum. Methods Phys. Res. A, 758, 1–3.
Abstract: The differential Recoil Distance Doppler Shift (RDDS) method after multinucleon transfer (MNT) reactions to measure lifetimes of excited states in neutron-rich nuclei requires the use of a thick energy degrader for the recoiling ejectiles that are then detected in a spectrometer. This type of measurements greatly benefits from the use of the new generation segmented gamma-ray detectors, such as the AGATA demonstrator which offers unprecedented energy and angular resolutions. In order to make an optimized choice of the material and the thickness of the degrader for lifetime measurements using the RODS method after MNT, an experiment has been performed with the AGATA demonstrator. Counting rate measurements for different degraders are presented.
|
|
|
Jaworski, G., Palacz, M., Nyberg, J., de Angelis, G., de France, G., Di Nitto, A., et al. (2012). Monte Carlo simulation of a single detector unit for the neutron detector array NEDA. Nucl. Instrum. Methods Phys. Res. A, 673, 64–72.
Abstract: A study of the dimensions and performance of a single detector of the future neutron detector array NEDA was performed by means of Monte Carlo simulations, using GEANT4. Two different liquid scintillators were evaluated: the hydrogen based BC501A and the deuterated BC537. The efficiency and the probability that one neutron will trigger a signal in more than one detector were investigated as a function of the detector size. The simulations were validated comparing the results to experimental measurements performed with two existing neutron detectors, with different geometries, based on the liquid scintillator BC501.
|
|