|
IGISOL Collaboration(Briz, J. A. et al), Algora, A., Tain, J. L., Guadilla, V., Agramunt, J., Estevez, E., et al. (2016). Total absorption spectroscopy of fission fragments relevant for reactor antineutrino spectra determination. Acta Phys. Pol. B, 47(3), 755–762.
Abstract: The contribution of each fission fragment to the reactor antineutrino spectra was determined using the summation method based on the existing information on fission yields and decay data contained in nuclear databases and the reactor evolution code MURE. The beta decay of some of the main contributors has been studied using the Total Absorption Spectroscopy (TAS) technique during two experimental campaigns at the IGISOL facility, in Jyvaskyla (Finland). Results on the decay of Rb-92, the most important contributor in the 4-8 MeV energy region are reported. The status of the analysis of the second experiment is presented as well.
|
|
|
Nacher, E., Briz, J. A., Nerio, A. N., Perea, A., Tavora, V. G., Tengblad, O., et al. (2024). Characterization of a novel proton-CT scanner based on Silicon and LaBr3(Ce) detectors. Eur. Phys. J. Plus, 139(5), 404–9pp.
Abstract: Treatment planning systems at proton-therapy centres entirely use X-ray computed tomography (CT) as primary imaging technique to infer the proton treatment doses to tumour and healthy tissues. However, proton stopping powers in the body, as derived from X-ray images, suffer from important proton-range uncertainties. In order to reduce this uncertainty in range, one could use proton-CT images instead. The main goal of this work is to test the capabilities of a newly-developed proton-CT scanner, based on the use of a set of tracking detectors and a high energy resolution scintillator for the residual energy of the protons. Different custom-made phantoms were positioned at the field of view of the scanner and were irradiated with protons at the CCB proton-therapy center in Krakow. We measured with the phantoms at different angles and produced sinograms that were used to obtain reconstructed images by Filtered Back-Projection. The obtained images were used to determine the capabilities of our scanner in terms of spatial resolution and proton Relative Stopping Power (RSP) mapping and validate its use as proton-CT scanner. The results show that the scanner can produce medium-high quality images, with spatial resolution better than 2 mm in radiography, below 3 mm in tomography and resolving power in the RSP comparable to other state-of-the-art pCT scanners.
|
|
|
Pragati, Deo, A. Y., Podolyak, Z., Walker, P. M., Algora, A., Rubio, B., et al. (2016). Decay of the N=126, Fr-213 nucleus. Phys. Rev. C, 94(6), 064316–8pp.
Abstract: gamma rays following the EC/beta(+) and alpha decay of the N = 126, Fr-213 nucleus have been observed at the CERN isotope separator on-line (ISOLDE) facility with the help of gamma-ray and conversion-electron spectroscopy. These gamma rays establish several hitherto unknown excited states in Rn-213. Also, five new a-decay branches from the Fr-213 ground state have been discovered. Shell model calculations have been performed to understand the newly observed states in Rn-213.
|
|
|
Viñals, S., Nacher, E., Tengblad, O., Borge, M. J. G., Briz, J. A., Gad, A., et al. (2021). Calibration and response function of a compact silicon-detector set-up for charged-particle spectroscopy using GEANT4. Eur. Phys. J. A, 57(2), 49–9pp.
Abstract: A complete methodology for detector calibration and energy-loss correction in charged-particle spectroscopy is presented. This has been applied to a compact set-up of four silicon detectors used for beta-delayed particle spectroscopy. The characterisation of the set-up was carried out using GEANT4 Monte Carlo simulations and standard alpha-calibration sources. The response function of the system was in this way accurately determined to be used for spectral unfolding.
|
|