Briz, J. A., Nerio, A. N., Ballesteros, C., Borge, M. J. G., Martinez, P., Perea, A., et al. (2022). Proton Radiographs Using Position-Sensitive Silicon Detectors and High-Resolution Scintillators. IEEE Trans. Nucl. Sci., 69(4), 696–702.
Abstract: Proton therapy is a cancer treatment technique currently in growth since it offers advantages with respect to conventional X-ray and gamma-ray radiotherapy. In particular, better control of the dose deposition allowing to reach higher conformity in the treatments causing less secondary effects. However, in order to take full advantage of its potential, improvements in treatment planning and dose verification are required. A new prototype of proton computed tomography scanner is proposed to design more accurate and precise treatment plans for proton therapy. Our prototype is formed by double-sided silicon strip detectors and scintillators of LaBr3(Ce) with high energy resolution and fast response. Here, the results obtained from an experiment performed using a 100-MeV proton beam are presented. Proton radiographs of polymethyl methacrylate (PMMA) samples of 50-mm thickness with spatial patterns in aluminum were taken. Their properties were studied, including reproduction of the dimensions, spatial resolution, and sensitivity to different materials. Structures of up to 2 mm are well resolved and the sensitivity of the system was enough to distinguish the thicknesses of 10 mm of aluminum or PMMA. The spatial resolution of the images was 0.3 line pairs per mm (MTF-10%). This constitutes the first step to validate the device as a proton radiography scanner.
|
Brunet, M. et al, & Nacher, E. (2021). Competition between allowed and first-forbidden beta decays of At-208 and expansion of the Po-208 level scheme. Phys. Rev. C, 103(5), 054327–13pp.
Abstract: The structure of Po-208 populated through the EC/beta(+) decay of At-208 is investigated using gamma-ray spectroscopy at the ISOLDE Decay Station. The presented level scheme contains 27 new excited states and 43 new transitions, as well as a further 50 previously observed. rays which have been (re)assigned a position. The level scheme is compared to shell model calculations. Through this analysis approximately half of the beta-decay strength of At-208 is found to proceed via allowed decay and half via first-forbidden decay. The first-forbidden transitions predominantly populate core excited states at high excitation energies, which is qualitatively understood using shell model considerations. This mass region provides an excellent testing ground for the competition between allowed and first-forbidden beta-decay calculations, important for the detailed understanding of the nucleosynthesis of heavy elements.
|
Caballero, L., Rubio, B., Kleinheinz, P., Yates, S. W., Algora, A., Dewald, A., et al. (2010). Two-phonon octupole excitation in Gd-146. Phys. Rev. C, 81(3), 031301–4pp.
Abstract: Based on experimental evidence from the Sm-144(alpha,2n) reaction, the 3484.7- keV 6(+) state in Gd-146 is identified as the highest-spin member of the 3(-) circle times 3(-) two-phonon octupole quartet. A previously unknown gamma line of 1905.8 keV and E3 character feeding the 3(-) octupole state has been observed. These results represent the first observation of a 6(+) -> 3(-) -> 0(+) cascade of two E3 transitions in an even-even nucleus and provide strong support for the interpretation of the 6(+) state as a two-phonon octupole excitation.
|
Cabanelas, P. et al, & Nacher, E. (2020). Performance recovery of long CsI(Tl) scintillator crystals with APD-based readout. Nucl. Instrum. Methods Phys. Res. A, 965, 163845–6pp.
Abstract: CALIFA is the high efficiency and energy resolution calorimeter for the (RB)-B-3 experiment at FAIR, intended for detecting high energy light charged particles and gamma rays in scattering experiments, and is being commissioned during the Phase-0 experiments at FAIR, between 2018 and 2020. It surrounds the reaction target in a segmented configuration with 2432 detection units made of long CsI(Tl) finger-shaped scintillator crystals. CALIFA has a 10 year intended operational lifetime as the (RB)-B-3 calorimeter, necessitating measures to be taken to ensure enduring performance. In this paper we present a systematic study of two groups of 6 different detection units of the CALIFA detector after more than four years of operation. The energy resolution and light output yield are evaluated under different conditions. Tests cover the aging of the first detector units assembled and investigates recovery procedures for degraded detection units. A possible reason for the observed degradation is given, pointing to the crystal-APD coupling.
|
Estevez, E. et al, Algora, A., Rubio, B., Bernabeu, J., Nacher, E., Tain, J. L., et al. (2011). beta-decay study of (150)Er, (152)Yb, and (156)Yb: Candidates for a monoenergetic neutrino beam facility. Phys. Rev. C, 84(3), 034304–6pp.
Abstract: The beta decays of (150)Er, (152)Yb, and (156)Yb nuclei are investigated using the total absorption spectroscopy technique. These nuclei can be considered possible candidates for forming the beam of a monoenergetic neutrino beam facility based on the electron capture (EC) decay of radioactive nuclei. Our measurements confirm that for the cases studied the EC decay proceeds mainly to a single state in the daughter nucleus.
|