Kuhn, K. et al, & Nacher, E. (2021). Experimental study of the nature of the 1(-) and 2(-) excited excited states in Be-10 using the Be-11(p, d) reaction in inverse kinematics. Phys. Rev. C, 104(4), 044601–10pp.
Abstract: The nature of the 1(-) and 2(-) excited states in Be-10 is studied using the Be-11(p, d) transfer reaction in inverse kinematics at 10A MeV at TRIUMF ISAC-II, in particular to assess whether either of them can be considered as an excited halo state. The angular distributions for both states are extracted using deuteron-gamma( )coincidences and analyzed using a transfer model taking into account one-step and two-step processes. A good fit of the angular distributions is obtained considering only the one-step process, whereby an inner p(3/2) neutron of Be-11 is removed, leaving the halo neutron intact. Higher-order processes however cannot be rejected. The small spectroscopic factors extracted suggest that the structure of both states is not uniquely halo-like, but rather display a more complex configuration mixing cluster and halo structures. Further insights are limited, as this experiment specifically probed the halo-like (but not cluster-like) Be-11 (1/2(+)) circle times (nu p(3/2))(-1) configuration in both states.
|
Mistry, A. K. et al, Tain, J. L., Agramunt, J., Algora, A., Guadilla, V., Morales, A. I., et al. (2022). The DESPEC setup for GSI and FAIR. Nucl. Instrum. Methods Phys. Res. A, 1033, 166662–18pp.
Abstract: The DEcay SPECtroscopy (DESPEC) setup for nuclear structure investigations was developed and commissioned at GSI, Germany in preparation for a full campaign of experiments at the FRS and Super-FRS. In this paper, we report on the first employment of the setup in the hybrid configuration with the AIDA implanter coupled to the FATIMA LaBr3(Ce) fast-timing array, and high-purity germanium detectors. Initial results are shown from the first experiments carried out with the setup. An overview of the setup and function is discussed, including technical advancements along the path.
|
Nacher, E., Briz, J. A., Nerio, A. N., Perea, A., Tavora, V. G., Tengblad, O., et al. (2024). Characterization of a novel proton-CT scanner based on Silicon and LaBr3(Ce) detectors. Eur. Phys. J. Plus, 139(5), 404–9pp.
Abstract: Treatment planning systems at proton-therapy centres entirely use X-ray computed tomography (CT) as primary imaging technique to infer the proton treatment doses to tumour and healthy tissues. However, proton stopping powers in the body, as derived from X-ray images, suffer from important proton-range uncertainties. In order to reduce this uncertainty in range, one could use proton-CT images instead. The main goal of this work is to test the capabilities of a newly-developed proton-CT scanner, based on the use of a set of tracking detectors and a high energy resolution scintillator for the residual energy of the protons. Different custom-made phantoms were positioned at the field of view of the scanner and were irradiated with protons at the CCB proton-therapy center in Krakow. We measured with the phantoms at different angles and produced sinograms that were used to obtain reconstructed images by Filtered Back-Projection. The obtained images were used to determine the capabilities of our scanner in terms of spatial resolution and proton Relative Stopping Power (RSP) mapping and validate its use as proton-CT scanner. The results show that the scanner can produce medium-high quality images, with spatial resolution better than 2 mm in radiography, below 3 mm in tomography and resolving power in the RSP comparable to other state-of-the-art pCT scanners.
|
Nacher, E., Rubio, B., Algora, A., Cano-Ott, D., Tain, J. L., Gadea, A., et al. (2016). Observations of the Gamow-Teller resonance in the rare-earth nuclei above Gd-146 populated in beta decay. Phys. Rev. C, 93(1), 014308–13pp.
Abstract: The rare-earth region of the nuclear table around the quasi-doubly magic nucleus Gd-146 is one of the very few places in which the Gamow-Teller (GT) resonance can be populated in beta decay. The appropriate technique to study such a phenomenon is total absorption spectroscopy, thanks to which one can measure the B(GT) distribution in beta-decay experiments even when it is very fragmented and lies at high excitation energy in the daughter nucleus. Results on the GT resonance measured in the beta decay of the odd-Z, N = 83 nuclei Tb-148, Ho-150, and Tm-152 are presented in this work and compared with shell-model calculations. The tail of the resonance is clearly observed up to the limit imposed by the Q value. This observation is important in the context of the understanding of the “quenching” of the GT strength.
|
Olleros, P., Caballero, L., Domingo-Pardo, C., Babiano, V., Ladarescu, I., Calvo, D., et al. (2018). On the performance of large monolithic LaCl3(Ce) crystals coupled to pixelated silicon photosensors. J. Instrum., 13, P03014–17pp.
Abstract: We investigate the performance of large area radiation detectors, with high energy-and spatial-resolution, intended for the development of a Total Energy Detector with gamma-ray imaging capability, so-called i-TED. This new development aims for an enhancement in detection sensitivity in time-of-flight neutron capture measurements, versus the commonly used C6D6 liquid scintillation total-energy detectors. In this work, we study in detail the impact of the readout photosensor on the energy response of large area (50 x 50 mm(2)) monolithic LaCl3(Ce) crystals, in particular when replacing a conventional mono-cathode photomultiplier tube by an 8 x 8 pixelated silicon photomultiplier. Using the largest commercially available monolithic SiPM array (25 cm(2)), with a pixel size of 6 x 6 mm(2), we have measured an average energy resolution of 3.92% FWHM at 662 keV for crystal thick-nesses of 10, 20 and 30 mm. The results are confronted with detailed Monte Carlo (MC) calculations, where optical processes and properties have been included for the reliable tracking of the scintillation photons. After the experimental validation of the MC model, we use our MC code to explore the impact of a smaller photosensor segmentation on the energy resolution. Our optical MC simulations predict only a marginal deterioration of the spectroscopic performance for pixels of 3 x 3 mm(2).
|