Colonna, N., Belloni, F., Berthoumieux, E., Calviani, M., Domingo-Pardo, C., Guerrero, C., et al. (2010). Advanced nuclear energy systems and the need of accurate nuclear data: the n_TOF project at CERN. Energy Environ. Sci., 3(12), 1910–1917.
Abstract: To satisfy the world's constantly increasing demand for energy, a suitable mix of different energy sources has to be devised. In this scenario, an important role could be played by nuclear energy, provided that major safety, waste and proliferation issues affecting current nuclear reactors are satisfactorily addressed. To this purpose, a large effort has been under way for a few years towards the development of advanced nuclear systems with the aim of closing the fuel cycle. Generation IV reactors, with full or partial waste recycling capability, accelerator driven systems, as well as new fuel cycles are the main options being investigated. The design of advanced systems requires improvements in basic nuclear data, such as cross-sections for neutron-induced reactions on actinides. In this paper, the main concepts of advanced reactor systems are described, together with the related needs of new and accurate nuclear data. The present activity in this field at the neutron facility n_TOF at CERN is discussed.
|
De La Torre Luque, P., Gaggero, D., Grasso, D., & Marinelli, A. (2022). Prospects for detection of a galactic diffuse neutrino flux. Front. Astron. Space Sci., 9, 1041838–9pp.
Abstract: A Galactic cosmic-ray transport model featuring non-homogeneous transport has been developed over the latest years. This setup is aimed at reproducing gamma-ray observations in different regions of the Galaxy (with particular focus on the progressive hardening of the hadronic spectrum in the inner Galaxy) and was shown to be compatible with the very-high-energy gamma-ray diffuse emission recently detected up to PeV energies. In this work, we extend the results previously presented to test the reliability of that model throughout the whole sky. To this aim, we compare our predictions with detailed longitude and latitude profiles of the diffuse gamma-ray emission measured by Fermi-LAT for different energies and compute the expected Galactic nu diffuse emission, comparing it with current limits from the ANTARES collaboration. We emphasize that the possible detection of a Galactic nu component will allow us to break the degeneracy between our model and other scenarios featuring prominent contributions from unresolved sources and TeV halos.
|
de Salas, P. F., Gariazzo, S., Mena, O., Ternes, C. A., & Tortola, M. (2018). Neutrino Mass Ordering From Oscillations and Beyond: 2018 Status and Future Prospects. Front. Astron. Space Sci., 5, 36–50pp.
Abstract: The ordering of the neutrino masses is a crucial input for a deep understanding of flavor physics, and its determination may provide the key to establish the relationship among the lepton masses and mixings and their analogous properties in the quark sector. The extraction of the neutrino mass ordering is a data-driven field expected to evolve very rapidly in the next decade. In this review, we both analyse the present status and describe the physics of subsequent prospects. Firstly, the different current available tools to measure the neutrino mass ordering are described. Namely, reactor, long-baseline (accelerator and atmospheric) neutrino beams, laboratory searches for beta and neutrinoless double beta decays and observations of the cosmic background radiation and the large scale structure of the universe are carefully reviewed. Secondly, the results from an up-to-date comprehensive global fit are reported: the Bayesian analysis to the 2018 publicly available oscillation and cosmological data sets provides strong evidence for the normal neutrino mass ordering vs. the inverted scenario, with a significance of 3.5 standard deviations. This preference for the normal neutrino mass ordering is mostly due to neutrino oscillation measurements. Finally, we shall also emphasize the future perspectives for unveiling the neutrinomass ordering. In this regard, apart from describing the expectations from the aforementioned probes, we also focus on those arising from alternative and novel methods, as 21 cm cosmology, core-collapse supernova neutrinos and the direct detection of relic neutrinos.
|
de Souza, P. M., Muller, A., Beniaich, A., Mayer-Miebach, E., Oehlke, K., Stahl, M., et al. (2015). Functional properties and nutritional composition of liquid egg products treated in a coiled tube UV-C reactor. Innov. Food Sci. Emerg. Technol., 32, 156–164.
Abstract: Pasteurization of eggs has adverse effects on nutrient composition and functionality of egg proteins. UV processing is an alternative technology with potentially fewer adverse effects as it is less intrusive. Egg white, whole egg and egg yolk vitamins (A, B-2, B-5, C and E), minerals (P, Cl, K, Na, Ca, Mg, Fe and Zn) and main secondary metabolites (lutein and zeaxanthin) were examined after exposure to UV in a coiled tube UV-C reactor at doses known to achieve microbiologically stable egg fractions. The studied nutrients were fairly stable to a treatment with UVC light with the exception of retinal, vitamin C and carotenoids, which showed loses up to 80%, 66% and 61%, respectively. Moreover, the functional properties of ultraviolet-treated eggs were investigated. Results showed a positive impact on the foam ability and foam stability, and an increase on the emulsifying activity index above 20% versus pasteurized samples. Processing with UV can maintain most of the egg nutritive properties, and retain or even improve the technological properties of foaming and emulsification in eggs. Industrial relevance:: This novel UV-C system can be applied successfully to the Food Industry. UV-C does not impair nutritional damage to egg-treated products, and even improve egg functional properties.
|
Deltoro, J. M. et al, Gadea, A., Perez-Vidal, R. M., Huyuk, T., & Illicachi, R. (2025). Implementation of a double trigger condition system based on charge comparison and TOF measurement for the NEDA detector array. Nucl. Sci. Tech., 36(2), 30–9pp.
Abstract: The NEutron Detector Array (NEDA) is designed to be coupled to gamma-ray spectrometers to enhance the sensitivity of the setup by enabling reaction channel selection through counting of the evaporated neutrons. This article presents the implementation of a double trigger condition system for NEDA, which improves the acquisition of neutrons and reduces the number of gamma rays acquired. Two independent triggers are generated in the double trigger condition system: one based on charge comparison (CC) and the other on time-of-flight (TOF). These triggers can be combined using OR and AND logic, offering four distinct trigger modes. The developed firmware is added to the previous one in the Virtex 6 field programmable gate array (FPGA) present in the system, which also includes signal processing, baseline correction, and various trigger logic blocks. The performance of the trigger system is evaluated using data from the E703 experiment performed at GANIL. The four trigger modes are applied to the same data, and a subsequent offline analysis is performed. It is shown that most of the detected neutrons are preserved with the AND mode, and the total number of gamma rays is significantly reduced. Compared with the CC trigger mode, the OR trigger mode allows increasing the selection of neutrons. In addition, it is demonstrated that if the OR mode is selected, the online CC trigger threshold can be raised without losing neutrons.
|
DEPFET collaboration(Alonso, O. et al), Boronat, M., Esperante-Pereira, D., Fuster, J., Garcia, I. G., Lacasta, C., et al. (2013). DEPFET Active Pixel Detectors for a Future Linear e(+)e(-) Collider. IEEE Trans. Nucl. Sci., 60(2), 1457–1465.
Abstract: The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key principle, the integration of a first amplification stage in a detector-grade sensor material, can provide a comfortable signal to noise ratio of over 40 for a sensor thickness of 50-75 μm. ASICs have been designed and produced to operate a DEPFET pixel detector with the required read-out speed. A complete detector concept is being developed, including solutions for mechanical support, cooling, and services. In this paper, the status of the DEPFET R & D project is reviewed in the light of the requirements of the vertex detector at a future linear e(+)e(-) collider.
|
Dilator, J. M., Jaworski, G., Goasduff, A., Gonzalez, V., Gadea, A., Palacz, M., et al. (2025). Reconstruction of pile-up events using a one-dimensional convolutional autoencoder for the NEDA detector array. Nucl. Sci. Tech., 36(2), 32–9pp.
Abstract: Pulse pile-up is a problem in nuclear spectroscopy and nuclear reaction studies that occurs when two pulses overlap and distort each other, degrading the quality of energy and timing information. Different methods have been used for pile-up rejection, both digital and analogue, but some pile-up events may contain pulses of interest and need to be reconstructed. The paper proposes a new method for reconstructing pile-up events acquired with a neutron detector array (NEDA) using an one-dimensional convolutional autoencoder (1D-CAE). The datasets for training and testing the 1D-CAE are created from data acquired from the NEDA. The new pile-up signal reconstruction method is evaluated from the point of view of how similar the reconstructed signals are to the original ones. Furthermore, it is analysed considering the result of the neutron-gamma discrimination based on charge comparison, comparing the result obtained from original and reconstructed signals.
|
Dimmock, M. R., Nikulin, D. A., Gillam, J. E., & Nguyen, C. V. (2012). An OpenCL Implementation of Pinhole Image Reconstruction. IEEE Trans. Nucl. Sci., 59(4), 1738–1749.
Abstract: AC++/OpenCL software platform for emission image reconstruction of data from pinhole cameras has been developed. The software incorporates a new, accurate but computationally costly, probability distribution function for operating on list-mode data from detector stacks. The platform architecture is more general than previous works, supporting advanced models such as arbitrary probability distribution, collimation geometry and detector stack geometry. The software was implemented such that all performance-critical operations occur on OpenCL devices, generally GPUs. The performance of the software is tested on several commodity CPU and GPU devices.
|
Egea Canet, F. J. et al, Gadea, A., & Huyuk, T. (2015). A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors. IEEE Trans. Nucl. Sci., 62(3), 1056–1062.
Abstract: This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected specifications on both systems, but it also showed how a study of synergy between detectors could lead to the reduction of resources and time by applying a common strategy.
|
Egea Canet, F. J. et al, Gadea, A., & Huyuk, T. (2015). Digital Front-End Electronics for the Neutron Detector NEDA. IEEE Trans. Nucl. Sci., 62(3), 1063–1069.
Abstract: This paper presents the design of the NEDA (Neutron Detector Array) electronics, a first attempt to involve the use of digital electronics in large neutron detector arrays. Starting from the front-end modules attached to the PMTs (PhotoMultiplier Tubes) and ending up with the data processing workstations, a comprehensive electronic system capable of dealing with the acquisition and pre-processing of the neutron array is detailed. Among the electronic modules required, we emphasize the front-end analog processing, the digitalization, digital pre-processing and communications firmware, as well as the integration of the GTS (Global Trigger and Synchronization) system, already used successfully in AGATA (Advanced Gamma Tracking Array). The NEDA array will be available for measurements in 2016.
|