Hueso-Gonzalez, F., Casaña Copado, J. V., Fernandez Prieto, A., Gallas Torreira, A., Lemos Cid, E., Ros Garcia, A., et al. (2022). A dead-time-free data acquisition system for prompt gamma-ray measurements during proton therapy treatments. Nucl. Instrum. Methods Phys. Res. A, 1033, 166701–9pp.
Abstract: In cancer patients undergoing proton therapy, a very intense secondary radiation is produced during the treatment, which lasts around one minute. About one billion prompt gamma-rays are emitted per second, and their detection with fast scintillation detectors is useful for monitoring a correct beam delivery. To cope with the expected count rate and pile-up, as well as the scarce statistics due to the short treatment duration, we developed an eidetic data acquisition system capable of continuously digitizing the detector signal with a high sampling rate and without any dead time. By streaming the fully unprocessed waveforms to the computer, complex pile-up decomposition algorithms can be applied and optimized offline. We describe the data acquisition architecture and the multiple experimental tests designed to verify the sustained data throughput speed and the absence of dead time. While the system is tailored for the proton therapy environment, the methodology can be deployed in any other field requiring the recording of raw waveforms at high sampling rates with zero dead time.
|
|
|
Linhart, V., Burdette, D., Chessi, E., Cindro, V., Clinthorne, N. H., Cochran, E., et al. (2011). Spectroscopy study of imaging devices based on silicon Pixel Array Detector coupled to VATAGP7 read-out chips. J. Instrum., 6, C01092–8pp.
Abstract: Spectroscopic and timing response studies have been conducted on a detector module consisting of a silicon Pixel Array Detector bonded on two VATAGP7 read-out chips manufactured by Gamma-Medica Ideas using laboratory gamma sources and the internal calibration facilities (the calibration system of the read-out chips). The performed tests have proven that the chips have (i) non-linear calibration curves which can be approximated by power functions, (ii) capability to measure the energy of photons with energy resolution better than 2 keV (exact range and resolution depend on experimental setup), (iii) the internal calibration facility which provides 6 out of 16 available internal calibration charges within our region of interest (spanning the Compton edge of 511 keV photons). The peaks induced by the internal calibration facility are suitable for a fit of the calibration curves. However, they are not suitable for measurements of equivalent noise charge because their full width at half maximum varies with their amplitude. These facts indicate that the VATAGP7 chips are useful and precise tools for a wide variety of spectroscopic devices. We have also explored time walk of the module and peaking time of the spectroscopy signals provided by the chips. We have observed that (iv) the time walk is caused partly by the peaking time of the signals provided by the fast shaper of the chips and partly by the timing uncertainty related to the varying position of the photon interaction, (v) the peaking time of the spectroscopy signals provided by the chips increases with increasing pulse height.
|
|
|
Llosa, G. (2019). SiPM-based Compton cameras. Nucl. Instrum. Methods Phys. Res. A, 926, 148–152.
Abstract: Compton cameras have been developed for almost fifty years in various fields (astronomy, medical imaging, safety and industrial inspections, etc.), employing different types of detectors. Their potential use has gained renewed interest with the emergence of high light yield scintillator crystals and silicon photomultipliers (SiPMs). This combination provides good performance and operation simplicity at an affordable cost, raising again the interest in this type of systems. SiPM-based Compton cameras are being assessed for diverse applications with promising results.
|
|
|
Llosa, G. (2015). Recent developments in photodetection for medical applications. Nucl. Instrum. Methods Phys. Res. A, 787, 353–357.
Abstract: The use of the most advanced technology in medical imaging results in the development of high performance detectors that can significantly improve the performance of the medical devices employed in hospitals. Scintillator crystals coupled to photodetectors remain to be essential detectors in terms of performance and cost for medical imaging applications in different imaging modalities. Recent advances in photodetectors result in an increase of the performance of the medical scanners. Solid state detectors can provide substantial performance improvement, but are more complex to integrate into clinical detectors due mainly to their higher cost. Solid state photodetectors (APDs, SiPMs) have made new detector concepts possible and have led to improvements in different imaging modalities. Recent advances in detectors for medical imaging are revised.
|
|
|
Llosa, G., Barrillon, P., Barrio, J., Bisogni, M. G., Cabello, J., Del Guerra, A., et al. (2013). High performance detector head for PET and PET/MR with continuous crystals and SiPMs. Nucl. Instrum. Methods Phys. Res. A, 702, 3–5.
Abstract: A high resolution PET detector head for small animal PET applications has been developed. The detector is composed of a 12 mm x 12 mm continuous LYSO crystal coupled to a 64-channel monolithic SiPM matrix from FBK-irst. Crystal thicknesses of 5 mm and 10 mm have been tested, both yielding an intrinsic spatial resolution around 0.7 mm FWHM with a position determination algorithm that can also provide depth-of-interaction information. The detectors have been tested in a rotating system that makes it possible to acquire tomographic data and reconstruct images of Na-22 sources. An image reconstruction method specifically adapted for continuous crystals has been employed. The Full Width at Half Maximum measured from a point source reconstructed with ML-EM was 0.7 mm with the 5 mm crystal and 0.8 mm with the 10 mm crystal.
|
|