|
Birkenbach, B. et al, & Gadea, A. (2015). Spectroscopy of the neutron-rich actinide nucleus U-240 following multinucleon-transfer reactions. Phys. Rev. C, 92(4), 044319–9pp.
Abstract: Background: Nuclear structure information for the neutron-rich actinide nuclei is important since it is the benchmark for theoretical models that provide predictions for the heaviest nuclei. Purpose: gamma-ray spectroscopy of neutron-rich heavy nuclei in the actinide region. Method: Multinucleon-transfer reactions in Zn-70 + U-238 and Xe-136 + U-238 have been measured in two experiments performed at the INFN Legnaro, Italy. In the Zn-70 experiment the high-resolution HPGe Clover Array (CLARA) coupled to the magnetic spectrometer PRISMA was employed. In the Xe-136 experiment the high-resolution Advanced Gamma Tracking Array (AGATA) was used in combination with PRISMA and the Detector Array for Multinucleon Transfer Ejectiles (DANTE). Results: The ground-state band (g.s. band) of U-240 was measured up to the 20(+) level and a tentative assignment was made up to the (24(+)) level. Results from gamma gamma coincidence and from particle coincidence analyses are shown. Moments of inertia (MoI) show a clear upbend. Evidence for an extended first negative-parity band of U-240 is found. Conclusions: A detailed comparison with latest calculations shows best agreement with cranked relativistic Hartree-Bogoliubov (CRHB) calculations for the g.s. band properties. The negative-parity band shows the characteristics of a K-pi = 0 band based on an octupole vibration.
|
|
|
Lewandowski, L., Reiter, P., Birkenbach, B., Bruyneel, B., Clemente, E., Eberth, J., et al. (2019). Pulse-Shape Analysis and position resolution in highly segmented HPGe AGATA detectors. Eur. Phys. J. A, 55(5), 81–13pp.
Abstract: The performance of the Pulse-Shape Analysis (PSA) in AGATA HPGe detectors was investigated and improved employing a -ray source measurement based on e+e- annihilation radiation after decays of Na-22 by + decay. The first interaction positions of the two 511keV rays were determined and the connecting line of these two positions was compared to the known source position as a measure for the PSA performance. The position resolution and its dependence on the PSA parameters were investigated by varying most relevant input quantities: the charge carrier mobility of the holes, the response of the employed measuring electronics especially the preamplifier rise time. The relative statistical weight of charge signals and transient signals was scrutinized. The optimal distance metric of the grid-search algorithm and its impact on the position resolution were determined.
|
|