|
MiniBooNE Collaboration(Aguilar-Arevalo, A. A. et al), & Sorel, M. (2011). Measurement of the neutrino component of an antineutrino beam observed by a nonmagnetized detector. Phys. Rev. D, 84(7), 072005–14pp.
Abstract: Two methods are employed to measure the neutrino flux of the antineutrino-mode beam observed by the MiniBooNE detector. The first method compares data to simulated event rates in a high-purity nu(mu)-induced charged-current single pi(+) (CC1 pi(+)) sample while the second exploits the difference between the angular distributions of muons created in nu(mu) and nu(mu) charged-current quasielastic (CCQE) interactions. The results from both analyses indicate the prediction of the neutrino flux component of the predominately antineutrino beam is overestimated-the CC1 pi(+) analysis indicates the predicted nu(mu) flux should be scaled by 0: 76 +/- 0: 11, while the CCQE angular fit yields 0: 65 +/- 0: 23. The energy spectrum of the flux prediction is checked by repeating the analyses in bins of reconstructed neutrino energy, and the results show that the spectral shape is well-modeled. These analyses are a demonstration of techniques for measuring the neutrino contamination of antineutrino beams observed by future nonmagnetized detectors.
|
|
|
MiniBooNE Collaboration(Aguilar-Arevalo, A. A. et al), & Sorel, M. (2011). Measurement of nu(mu)-induced charged-current neutral pion production cross sections on mineral oil at E-nu is an element of 0.5-2.0 GeV. Phys. Rev. D, 83(5), 052009–17pp.
Abstract: Using a custom 3-Cerenkov ring fitter, we report cross sections for nu(mu)-induced charged-current single pi(0) production on mineral oil (CH2) from a sample of 5810 candidate events with 57% signal purity over an energy range of 0.5-2.0 GeV. This includes measurements of the absolute total cross section as a function of neutrino energy, and flux-averaged differential cross sections measured in terms of Q(2), mu(-) kinematics, and pi(0) kinematics. The sample yields a flux-averaged total cross section of (9.2 +/- 0.3(stat) +/- 1.5(syst)) X 10(-39) cm(2)/CH2 at mean neutrino energy of 0.965 GeV.
|
|
|
MiniBooNE Collaboration(Aguilar-Arevalo, A. A. et al), & Sorel, M. (2011). Measurement of neutrino-induced charged-current charged pion production cross sections on mineral oil at E-nu similar to 1 GeV. Phys. Rev. D, 83(5), 052007–26pp.
Abstract: Using a high-statistics, high-purity sample of nu(mu)-induced charged current, charged pion events in mineral oil (CH2), MiniBooNE reports a collection of interaction cross sections for this process. This includes measurements of the CC pi+ cross section as a function of neutrino energy, as well as flux-averaged single-and double-differential cross sections of the energy and direction of both the final-state muon and pion. In addition, each of the single-differential cross sections are extracted as a function of neutrino energy to decouple the shape of the MiniBooNE energy spectrum from the results. In many cases, these cross sections are the first time such quantities have been measured on a nuclear target and in the 1 GeV energy range.
|
|
|
BABAR Collaboration(del Amo Sanchez, P. et al), Lopez-March, N., Martinez-Vidal, F., & Oyanguren, A. (2011). Dalitz plot analysis of D-s(+) -> K+ K- pi(+). Phys. Rev. D, 83(5), 052001–20pp.
Abstract: We perform a Dalitz plot analysis of about 100 000 D-s(+) decays to K+ K- pi(+) and measure the complex amplitudes of the intermediate resonances which contribute to this decay mode. We also measure the relative branching fractions of D-s(+) -> K+ K+ pi(-) and D-s(+) -> K+ K+ K-. For this analysis we use a 384 fb(-1) data sample, recorded by the BABAR detector at the PEP-II asymmetric-energy e(+)e(-) collider running at center-of-mass energies near 10.58 GeV.
|
|
|
Degiovanni, A., Amaldi, U., Bonomi, R., Garlasche, M., Garonna, A., Verdu-Andres, S., et al. (2011). TERA high gradient test program of RF cavities for medical linear accelerators. Nucl. Instrum. Methods Phys. Res. A, 657(1), 55–58.
Abstract: The scientific community and the medical industries are putting a considerable effort into the design of compact, reliable and cheap accelerators for hadrontherapy. Up to now only circular accelerators are used to deliver beams with energies suitable for the treatment of deep seated tumors. The TERA Foundation has proposed and designed a hadrontherapy facility based on the cyclinac concept: a high gradient linear accelerator placed downstream of a cyclotron used as an injector. The overall length of the linac, and therefore its final cost, is almost inversely proportional to the average accelerating gradient achieved in the linac. TERA, in collaboration with the CLIC RF group, has started a high gradient test program. The main goal is to study the high gradient behavior of prototype cavities and to determine the appropriate linac operating frequency considering important issues such as machine reliability and availability of distributed power sources. A preliminary test of a 3 GHz cavity has been carried out at the beginning of 2010, giving encouraging results. Further investigations are planned before the end of 2011. A set of 5.7 GHz cavities is under production and will be tested in a near future. The construction and test of a multi-cell structure is also foreseen.
|
|