|
Gomez, M. E., Lola, S., Ruiz de Austri, R., & Shafi, Q. (2018). Confronting SUSY GUT With Dark Matter, Sparticle Spectroscopy and Muon (g – 2). Front. Physics, 6, 127–9pp.
Abstract: We explore the implications of LHC and cold dark matter searches for supersymmetric particle mass spectra in two different grand unified models with left-right symmetry, SO(10) and SU(4)(c) x SU(2)(L) x SU(2)(R) (4-2-2). We identify characteristic differences between the two scenarios, which imply distinct correlations between experimental measurements and the particular structure of the GUT group. The gauge structure of 4-2-2 enhances significantly the allowed parameter space as compared to SO(10), giving rise to a variety of coannihilation scenarios compatible with the LHC data, LSP dark matter and the ongoing muon g-2 experiment.
|
|
|
Gomez, M. E., Lola, S., Ruiz de Austri, R., & Shafi, Q. (2018). Dark matter, sparticle spectroscopy and muon (g-2) in SU(4)(c) x SU(2)(L) x SU(2)(R). J. High Energy Phys., 10(10), 062–24pp.
Abstract: We explore the sparticle mass spectra including LSP dark matter within the framework of supersymmetric SU(4)(c) x SU(2)(L) x SU(2)(R) (422) models, taking into account the constraints from extensive LHC and cold dark matter searches. The soft supersymmetry-breaking parameters at M-GUT can be non-universal, but consistent with the 422 symmetry. We identify a variety of coannihilation scenarios compatible with LSP dark matter, and study the implications for future supersymmetry searches and the ongoing muon g-2 experiment.
|
|
|
Gisbert, H., & Pich, A. (2018). Direct CP violation in K-0 -> pi pi : Standard Model Status. Rep. Prog. Phys., 81(7), 076201–22pp.
Abstract: In 1988 the NA31 experiment presented the first evidence of direct CP violation in the K-0 -> pi pi decay amplitudes. A clear signal with a 7.2 sigma statistical significance was later established with the full data samples from the NA31, E731, NA48 and KTeV experiments, confirming that CP violation is associated with a Delta S = 1 quark transition, as predicted by the Standard Model. However, the theoretical prediction for the measured ratio epsilon'/epsilon has been a subject of strong controversy along the years. Although the underlying physics was already clarified in 2001, the recent release of improved lattice data has revived again the theoretical debate. We review the current status, discussing in detail the different ingredients that enter into the calculation of this observable and the reasons why seemingly contradictory predictions were obtained in the past by several groups. An update of the Standard Model prediction is presented and the prospects for future improvements are analysed. Taking into account all known short-distance and long-distance contributions, one obtains Re (epsilon' / epsilon) = (15 +/- 7) . 10(-4), in good agreement with the experimental measurement.
|
|
|
Gimenez-Alventosa, V., Gimenez, V., Ballester, F., Vijande, J., & Andreo, P. (2018). Correction factors for ionization chamber measurements with the 'Valencia' and 'large field Valencia' brachytherapy applicators. Phys. Med. Biol., 63(12), 125004–10pp.
Abstract: Treatment of small skin lesions using HDR brachytherapy applicators is a widely used technique. The shielded applicators currently available in clinical practice are based on a tungsten-alloy cup that collimates the source-emitted radiation into a small region, hence protecting nearby tissues. The goal of this manuscript is to evaluate the correction factors required for dose measurements with a plane-parallel ionization chamber typically used in clinical brachytherapy for the 'Valencia' and 'large field Valencia' shielded applicators. Monte Carlo simulations have been performed using the PENELOPE-2014 system to determine the absorbed dose deposited in a water phantom and in the chamber active volume with a Type A uncertainty of the order of 0.1%. The average energies of the photon spectra arriving at the surface of the water phantom differ by approximately 10%, being 384 keV for the 'Valencia' and 343 keV for the 'large field Valencia'. The ionization chamber correction factors have been obtained for both applicators using three methods, their values depending on the applicator being considered. Using a depth-independent global chamber perturbation correction factor and no shift of the effective point of measurement yields depth-dose differences of up to 1% for the 'Valencia' applicator. Calculations using a depth-dependent global perturbation factor, or a shift of the effective point of measurement combined with a constant partial perturbation factor, result in differences of about 0.1% for both applicators. The results emphasize the relevance of carrying out detailed Monte Carlo studies for each shielded brachytherapy applicator and ionization chamber.
|
|
|
Ghosh, P., Lara, I., Lopez-Fogliani, D. E., Muñoz, C., & Ruiz de Austri, R. (2018). Searching for left sneutrino LSP at the LHC. Int. J. Mod. Phys. A, 33(18-19), 1850110–62pp.
Abstract: We analyze relevant signals expected at the LHC for a left sneutrino as the lightest supersymmetric particle (LSP). The discussion is carried out in the “mu from nu” supersymmetric standard model (mu nu SSM), where the presence of R-parity breaking couplings involving right-handed neutrinos solves the μproblem and reproduces neutrino data. The sneutrinos are pair produced via a virtual W, Z or gamma in the s channel. From the prompt decay of a pair of left sneutrinos LSPs of any family, a significant diphoton signal plus missing transverse energy (MET) from neutrinos can be present in the mass range 118-132 GeV, with 13 TeV center-of-mass energy and an integrated luminosity of 100 fb(-1). In addition, in the case of a pair of tau left sneutrinos LSPs, given the large value of the tau Yukawa coupling diphoton plus leptons and/or multileptons can appear. We find that the number of expected events for the multilepton signal, together with properly adopted search strategies, is sufficient to give a significant evidence for a sneutrino of mass in the range 130-310 GeV, even with the integrated luminosity of 20 fb(-1). In the case of the signal producing diphoton plus leptons, an integrated luminosity of 100 fb(-1) is needed to give a significant evidence in the mass range 95-145 GeV. Finally, we discuss briefly the presence of displaced vertices and the associated range of masses.
|
|