|
Torres-Espallardo, I., Diblen, F., Rohling, H., Solevi, P., Gillam, J., Watts, D., et al. (2015). Evaluation of resistive-plate-chamber-based TOF-PET applied to in-beam particle therapy monitoring. Phys. Med. Biol., 60(9), N187–N208.
Abstract: Particle therapy is a highly conformal radiotherapy technique which reduces the dose deposited to the surrounding normal tissues. In order to fully exploit its advantages, treatment monitoring is necessary to minimize uncertainties related to the dose delivery. Up to now, the only clinically feasible technique for the monitoring of therapeutic irradiation with particle beams is Positron Emission Tomography (PET). In this work we have compared a Resistive Plate Chamber (RPC)-based PET scanner with a scintillation-crystal-based PET scanner for this application. In general, the main advantages of the RPC-PET system are its excellent timing resolution, low cost, and the possibility of building large area systems. We simulated a partial-ring scannerbeam monitoring, which has an intrinsically low positron yield compared to diagnostic PET. In addition, for in-beam PET there is a further data loss due to the partial ring configuration. In order to improve the performance of the RPC-based scanner, an improved version of the RPC detector (modifying the thickness of the gas and glass layers), providing a larger sensitivity, has been simulated and compared with an axially extended version of the crystal-based device. The improved version of the RPC shows better performance than the prototype, but the extended version of the crystal-based PET outperforms all other options. based on an RPC prototype under construction within the Fondazione per Adroterapia Oncologica (TERA). For comparison with the crystal-based PET scanner we have chosen the geometry of a commercially available PET scanner, the Philips Gemini TF. The coincidence time resolution used in the simulations takes into account the current achievable values as well as expected improvements of both technologies. Several scenarios (including patient data) have been simulated to evaluate the performance of different scanners. Initial results have shown that the low sensitivity of the RPC hampers its application to hadron
|
|
|
Martinez Torres, A., Khemchandani, K. P., Jido, D., Kanada-En'yo, Y., & Oset, E. (2013). Three-body hadron systems with strangeness. Nucl. Phys. A, 914, 280–288.
Abstract: Recently, many efforts are being put in studying three-hadron systems made of mesons and baryons and interesting results are being found. In this talk, we summarize the main features of the formalism used to study such three hadron systems with strangeness S = -1, 0 within a framework built on the basis of unitary chiral theories and solution of the Faddeev equations. In particular, we present the results obtained for the pi(K) over barN, K (K) over barN and KK (K) over bar systems and their respective coupled channels. In the first case, we find four Sigma's and two A's with spin-parity J(P) = 1/2(+), in the 1500-1800 MeV region, as two meson-one baryon s-wave resonances. In the second case, a 1/2(+) N* around 1900 MeV is found. For the last one a kaon close to 1420 MeV is formed, which can be identified with K(1460).
|
|
|
de Adelhart Toorop, R., Bazzocchi, F., & Morisi, S. (2012). Quark mixing in the discrete dark matter model. Nucl. Phys. B, 856(3), 670–681.
Abstract: We consider a model in which dark matter is stable as it is charged under a Z(2) symmetry that is residual after an A(4) flavour symmetry is broken. We consider the possibility to generate the quark masses by charging the quarks appropriately under A(4). We find that it is possible to generate the CKM mixing matrix by an interplay of renormalisable and dimension-six operators. In this set-up, we predict the third neutrino mixing angle to be large and the dark matter relic density to be in the correct range. Low energy observables – in particular meson-antimeson oscillations – are hard to facilitate. We find that only in a situation where there is a strong cancellation between the Standard Model contribution and the contribution of the new Higgs fields, B meson oscillations are under control.
|
|
|
Tonev, D. et al, & Gadea, A. (2021). Transition probabilities in P-31 and S-31: A test for isospin symmetry. Phys. Lett. B, 821, 136603–6pp.
Abstract: Excited states in the mirror nuclei P-31 and S-31 were populated in the 1p and 1n exit channels of the reaction Ne-20 + C-12, at a beam energy of 33 MeV. The Ne-20 beam was delivered for the first time by the Piave-Alpi accelerator of the Laboratori Nazionali di Legnaro. Angular correlations of coincident gamma-rays and Doppler-shift attenuation lifetime measurements were performed using the multi-detector array GASP in conjunction with the EUCLIDES charged particle detector. In the observed B(E1) strengths, the isoscalar component, amounting to 24% of the isovector one, provides strong evidence for breaking of the isospin symmetry in the A = 31 mass region. Self-consistent beyond mean field calculations using Equation of Motion method based on a chiral potential and including two- and three-body forces reproduce well the experimental B(E1) strengths, reinforcing our conclusion. Coherent mixing from higher-lying states involving the Giant Isovector Monopole Resonance accounts well for the effect observed. The breaking of the isospin symmetry originates from the violation of the charge symmetry of the two- and three-body parts of the potential, only related to the Coulomb interaction.
|
|
|
BRIKEN Collaboration(Tolosa-Delgado, A. et al), Agramunt, J., Tain, J. L., Algora, A., Domingo-Pardo, C., Morales, A. I., et al. (2019). Commissioning of the BRIKEN detector for the measurement of very exotic beta-delayed neutron emitters. Nucl. Instrum. Methods Phys. Res. A, 925, 133–147.
Abstract: A new detection system has been installed at the RIKEN Nishina Center (Japan) to investigate decay properties of very neutron-rich nuclei. The setup consists of three main parts: a moderated neutron counter, a detection system sensitive to the implantation and decay of radioactive ions, and gamma-ray detectors. We describe here the setup, the commissioning experiment and some selected results demonstrating its performance for the measurement of half-lives and beta-delayed neutron emission probabilities. The methodology followed in the analysis of the data is described in detail. Particular emphasis is placed on the correction of the accidental neutron background.
|
|
|
Tolos, L., Cabrera, D., Garcia-Recio, C., Molina, R., Nieves, J., Oset, E., et al. (2013). Strangeness and charm in nuclear matter. Nucl. Phys. A, 914, 461–471.
Abstract: The properties of strange (K, (K) over bar and (K) over bar*) and open-charm (D, (D) over bar and D*) mesons in dense matter are studied using a unitary approach in coupled channels for meson-baryon scattering. In the strangeness sector, the interaction with nucleons always comes through vector-meson exchange, which is evaluated by chiral and hidden gauge Lagrangians. For the interaction of charmed mesons with nucleons we extend the SU(3) Weinberg-Tomozawa Lagrangian to incorporate spin-flavor symmetry and implement a suitable flavor symmetry breaking. The in-medium solution for the scattering amplitude accounts for Pauli blocking effects and meson self-energies. On one hand, we obtain the K, (K) over bar and (K) over bar* spectral functions in the nuclear medium and study their behaviour at finite density, temperature and momentum. We also make an estimate of the transparency ratio of the gamma A -> K+ K*(-) A' reaction, which we propose as a tool to detect in-medium modifications of the (K) over bar* meson. On the other hand, in the charm sector, several resonances with negative parity are generated dynamically by the s-wave interaction between pseudoscalar and vector meson multiplets with 1/2(+) and 3/2(+) baryons. The properties of these states in matter are analyzed and their influence on the open-charm meson spectral functions is studied. We finally discuss the possible formation of D-mesic nuclei at FAIR energies.
|
|
|
Thakore, T., Devi, M. M., Agarwalla, S. K., & Dighe, A. (2018). Active-sterile neutrino oscillations at INO-ICAL over a wide mass-squared range. J. High Energy Phys., 08(8), 022–34pp.
Abstract: We perform a detailed analysis for the prospects of detecting active-sterile oscillations involving a light sterile neutrino, over a large Delta m(41)(2 )range of 10(-5) eV(2) to 10(2) eV(2), using 10 years of atmospheric neutrino data expected from the proposed 50 kt magnetized ICAL detector at the INO. This detector can observe the atmospheric nu(mu), and (nu) over bar (mu) separately over a wide range of energies and baselines, making it sensitive to the magnitude and sign of Arni i over a large range. If there is no light sterile neutrino, ICAL can place competitive upper limit on vertical bar U-mu 4 vertical bar(2) less than or similar to 0.02 at 90% C.L. for Delta m(41)(2) in the range (0.5-5) x 10(-3) eV(2). For the same vertical bar Delta m(41)(2)vertical bar range, ICAL would be able to determine its sign, exploiting the Earth's matter effect in mu(-) and mu(+) events separately if there is indeed a light sterile neutrino in Nature. This would help identify the neutrino mass ordering in the four-neutrino mixing scenario.
|
|
|
n_TOF Collaboration(Tarrio, D. et al), Domingo-Pardo, C., Giubrone, G., & Tain, J. L. (2014). Measurement of the angular distribution of fission fragments using a PPAC assembly at CERN n_TOF. Nucl. Instrum. Methods Phys. Res. A, 743, 79–85.
Abstract: A fission reaction chamber based on Parallel Plate Avalanche Counters (PPACs) was built for measuring angular distributions of fragments emitted in neutron-induced fission of actinides at the neutron beam available at the Neutron Time-Of-Flight (n_TOF) facility at CERN. The detectors and the samples were tilted 45 degrees with respect to the neutron beam direction to cover all the possible values of the emission angle of the fission fragments. The main features of this setup are discussed and results on the fission fragment angular distribution are provided for the Th-232(n,f) reaction around the fission threshold. The results are compared with the available data in the literature, demonstrating the good capabilities of this setup.
|
|
|
Tarifeño-Saldivia, A., & Soto, L. (2014). Effects of gas chamber geometry and gas flow on the neutron production in a fast plasma focus neutron source. Plasma Phys. Control. Fusion, 56(12), 125013–5pp.
Abstract: This work reports that gas chamber geometry and gas flow management substantially affect the neutron production of a repetitive fast plasma focus. The gas flow rate is the most sensitive parameter. An appropriate design of the gas chamber combined with a suitable flow-rate management can lead to improvements in the neutron production of one order of magnitude working in a fast repetitive mode.
|
|
|
Taprogge, J. et al, Gadea, A., & Montaner-Piza, A. (2014). Identification of a millisecond isomeric state in Cd-129(81) via the detection of internal conversion and Compton electrons. Phys. Lett. B, 738, 223–227.
Abstract: The decay of an isomeric state in the neutron-rich nucleus Cd-129 has been observed via the detection of internal conversion and Compton electrons providing first experimental information on excited states in this nucleus. The isomer was populated in the projectile fission of a U-238 beam at the Radioactive Isotope Beam Factory at RIKEN. From the measured yields of gamma-rays and internal conversion electrons, a multipolarity of E3 was tentatively assigned to the isomeric transition. A half-life of T-1/2 = 3.6(2) ms was determined for the new state which was assigned a spin of (21/2(+)), based on a comparison to shell model calculations performed using state-of-the-art realistic effective interactions.
|
|