Fernandez, A., Hufschmidt, D., Colaux, J. L., Valiente-Dobon, J. J., Godinho, V., Jimenez de Haro, M. C., et al. (2020). Low gas consumption fabrication of He-3 solid targets for nuclear reactions. Mater. Des., 186, 108337–10pp.
Abstract: Nanoporous solids that stabilize trapped gas nanobubbles open new possibilities to fabricate solid targets for nuclear reactions. A methodology is described based on the magnetron sputtering (MS) technique operated under quasistatic flux conditions to produce such nanocomposites films with He-3 contents of up to 16 at.% in an amorphous-silicon matrix. In addition to the characteristic low pressure (3-6 Pa) needed for the gas discharge, the method ensures almost complete reduction of the process gas flow during film fabrication. The method could produce similar materials to those obtained under classical dynamic flux conditions for MS. The drastic reduction (>99.5%) of the gas consumption is fundamental for the fabrication of targets with scarce and expensive gases. Si:He-3 and W:He-3 targets are presented together with their microstructural (scanning and transmission electron microscopy, SEM and TEM respectively) and compositional (Ion Beam Analysis, IBA) characterization. The He-3 content achieved was over 1 x 10(18) at/cm(2) for film thicknesses between 1.5 and 3 μm for both Si and W matrices. First experiments to probe the stability of the targets for nuclear reaction studies in inverse kinematics configurations are presented.
|
AGATA and PRISMA Collaborations(Gadea, A. et al). (2011). Conceptual design and infrastructure for the installation of the first AGATA sub-array at LNL. Nucl. Instrum. Methods Phys. Res. A, 654(1), 88–96.
Abstract: The first implementation of the AGATA spectrometer consisting of five triple germanium detector clusters has been installed at Laboratori Nazionali di Legnaro, INFN. This setup has two major goals, the first one is to validate the gamma-tracking concept and the second is to perform an experimental physics program using the stable beams delivered by the Tandem-PIAVE-ALPI accelerator complex. A large variety of physics topics will be addressed during this campaign, aiming to investigate both neutron and proton-rich nuclei. The setup has been designed to be coupled with the large-acceptance magnetic-spectrometer PRISMA. Therefore, the in-beam prompt gamma rays detected with AGATA will be measured in coincidence with the products of multinucleon-transfer and deep-inelastic reactions measured by PRISMA. Moreover, the setup is versatile enough to host ancillary detectors, including the heavy-ion detector DANTE, the gamma-ray detector array HELENA, the Cologne plunger for lifetime measurements and the Si-pad telescope TRACE. In this paper the design; characteristics and performance figures of the setup will be described.
|
Goasduff, A., Valiente-Dobon, J. J., Lunardi, S., Haas, F., Gadea, A., de Angelis, G., et al. (2014). Counting rate measurements for lifetime experiments using the RDDS method with the new generation gamma-ray array AGATA. Nucl. Instrum. Methods Phys. Res. A, 758, 1–3.
Abstract: The differential Recoil Distance Doppler Shift (RDDS) method after multinucleon transfer (MNT) reactions to measure lifetimes of excited states in neutron-rich nuclei requires the use of a thick energy degrader for the recoiling ejectiles that are then detected in a spectrometer. This type of measurements greatly benefits from the use of the new generation segmented gamma-ray detectors, such as the AGATA demonstrator which offers unprecedented energy and angular resolutions. In order to make an optimized choice of the material and the thickness of the degrader for lifetime measurements using the RODS method after MNT, an experiment has been performed with the AGATA demonstrator. Counting rate measurements for different degraders are presented.
|
Goasduff, A. et al, & Gadea, A. (2021). The GALILEO gamma-ray array at the Legnaro National Laboratories. Nucl. Instrum. Methods Phys. Res. A, 1015, 165753–15pp.
Abstract: GALILEO, a new 4 pi high-resolution gamma-detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital readout chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy gamma-ray transitions. In this work, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.
|
AGATA Collaboration(Goldkuhle, A. et al), Perez-Vidal, R. M., Domingo-Pardo, C., & Gadea, A. (2019). Lifetime measurements in Ti-52,Ti-54 to study shell evolution toward N=32. Phys. Rev. C, 100(5), 054317–12pp.
Abstract: Lifetimes of the excited states in the neutron-rich Ti-52,Ti-54 nuclei, produced in a multinucleon-transfer reaction, were measured by employing the Cologne plunger device and the recoil-distance Doppler-shift method. The experiment was performed at the Grand Accelerateur National d'Ions Lourds facility by using the Advanced Gamma Tracking Array for the gamma-ray detection, coupled to the large-acceptance variable mode spectrometer for an event-by-event particle identification. A comparison between the transition probabilities obtained from the measured lifetimes of the 2(1)(+) to 8(1)(+) yrast states in Ti-52,Ti-54 and that from the shell-model calculations based on the well-established GXPF1A, GXPF1B, and KB3G fp shell interactions support the N = 32 subshell closure. The B(E2) values for Ti-52 determined in this work are in disagreement with the known data, but are consistent with the predictions of the shell-model calculations and reduce the previously observed pronounced staggering across the even-even titanium isotopes.
|