Saha, S., Arici, T., Gerl, J., Gorska, M., Pietralla, N., Davinson, T., et al. (2020). On the 6-detection efficiency of a combined Si and plastic stack detector for DESPEC. Nucl. Instrum. Methods Phys. Res. A, 975, 164196–8pp.
Abstract: A Geant4 simulation has been carried out in order to determine the beta-detection efficiency of a rare isotope beam implantation setup, for decay spectroscopy experiments, comprising a number of Double Sided Silicon Strip Detectors (DSSSDs) and two plastic scintillation detectors placed upstream and downstream. The absolute efficiency for the emitted beta-particle detection from radioactive fragments implanted in the DSSSDs using fast-timing plastic-scintillator detector, is calculated. The detection efficiency of the setup has been studied with two different distances between the Si layers and plastics. The requirement for the thickness of the Si detector layers and its implication on the beta-detection efficiency has been investigated for 1 mm and 300 µm thickness of Si layers. The combined efficiency of DSSSD and plastic detectors were also simulated for two different thicknesses of the DSSSD.
|
|
|
Tain, J. L., Algora, A., Agramunt, J., Guadilla, V., Jordan, M. D., Montaner-Piza, A., et al. (2015). A decay total absorption spectrometer for DESPEC at FAIR. Nucl. Instrum. Methods Phys. Res. A, 803, 36–46.
Abstract: This paper presents the design of a total absorption gamma-ray spectrometer for the determination of beta-decay intensity distributions of exotic nuclear species at the focal plane of the FAIR-NUSTAR Super Fragment Separator. The spectrometer is a key instrument in the DESPEC experiment and the proposed implementation follows extensive design studies and prototype tests. Two options were contemplated, based on Nal(TI) and LaBr3:Ce inorganic scintillation crystals respectively. Monte Carlo simulations and technical considerations determined the optimal configurations consisting of sixteen 15 x 15 x 25 cm(3) crystals for the Nal(Tl) option and one hundred and twenty-eight 5.5 x 5.5 x 11 cm(3) crystals for the LaBr3:Ce option. Minimization of dead material was crucial for maximizing the spectrometer full-energy peak efficiency. Module prototypes were build to verify constructional details and characterize their performance. The measured energy and timing resolution was found to agree rather well with estimates based on simulations of scintillation light transport and collection. The neutron sensitivity of the spectrometer, important when measuring beta-delayed neutron emitters, was investigated by means of Monte Carlo simulations.
|
|