|
Gil, A., Blanco, A., Castro, E., Diaz, J., Garzon, J. A., Gonzalez-Diaz, D., et al. (2012). The slow control system of the HADES RPC wall. Nucl. Instrum. Methods Phys. Res. A, 661, S118–S120.
Abstract: The control and monitoring system for the new HADES RPC time of flight wall installed at GSI Helmholtzzentrum fur Schwerionenforschung GmbH (Darmstadt, Germany), is described. The slow control system controls/monitors about 6000 variables from different physical devices via a distributed architecture, which uses intensively the 1-wire (R) bus. The software implementation is based on the Experimental Physics and Industrial Control System (EPICS) software tool kit providing low cost, reliability and adaptability without requiring large hardware resources. The control and monitoring system attends five different subsystems: front-end electronics, low voltage, high voltage, gases, and detector. (C) 2010 Elsevier B.V. All rights reserved.
|
|
|
Gil, A., Diaz, J., Gomez-Cadenas, J. J., Herrero, V., Rodriguez, J., Serra, L., et al. (2012). Front-end electronics for accurate energy measurement of double beta decays. Nucl. Instrum. Methods Phys. Res. A, 695, 407–409.
Abstract: NEXT, a double beta decay experiment that will operate in Canfranc Underground Laboratory (Spain), aims at measuring the neutrinoless double-beta decay of the 136Xe isotope using a TPC filled with enriched Xenon gas at high pressure operated in electroluminescence mode. One technological challenge of the experiment is to achieve resolution better than 1% in the energy measurement using a plane of UV sensitive photomultipliers readout with appropriate custom-made front-end electronics. The front-end is designed to be sensitive to the single photo-electron to detect the weak primary scintillation light produced in the chamber, and also to be able to cope with the electroluminescence signal (several hundred times higher and with a duration of microseconds). For efficient primary scintillation detection and precise energy measurement of the electroluminescent signals the front-end electronics features low noise and adequate amplification. The signal shaping provided allows the digitization of the signals at a frequency as low as 40 MHz.
|
|
|
HADES Collaboration(Agakishiev, G. et al), Diaz, J., & Gil, A. (2010). Origin of the low-mass electron pair excess in light nucleus-nucleus collisions. Phys. Lett. B, 690(2), 118–122.
Abstract: We report measurements of electron pair production in elementary p + p and d + p reactions at 1.25 GeV/mu with the HADES spectrometer. For the first time, the electron pairs were reconstructed for n + p reactions by detecting the proton spectator from the deuteron breakup. We find that the yield of electron pairs with invariant mass Me+e- > 0.15 GeV/c(2) is about an order of magnitude larger in n + p reactions as compared to p + p. A comparison to model calculations demonstrates that the production mechanism is not sufficiently described yet. The electron pair spectra measured in C + C reactions are compatible with a superposition of elementary n + p and p + p collisions, leaving little room for additional electron pair sources in such light collision systems.
|
|
|
HADES Collaboration(Agakishiev, G. et al), Diaz, J., & Gil, A. (2010). Lambda-p femtoscopy in collisions of Ar + KCl at 1.76AGeV. Phys. Rev. C, 82(2), 021901–5pp.
Abstract: Results on Lambda p femtoscopy are reported at the lowest energy so far. At a beam energy of 1.76AGeV, the reaction Ar + KCl was studied with the High Acceptance Di-Electron Spectrometer ( HADES) at SIS18/GSI. A high-statistics and high-purity Lambda sample was collected, allowing for the investigation of Lambda p correlations at low relative momenta. The experimental correlation function is compared to corresponding model calculations allowing the determination of the space-time extent of the Lambda p emission source. The Lambda p source radius is found to be slightly smaller than the pp correlation radius for a similar collision system. The present Lambda p radius is significantly smaller than that found for Au + Au/Pb + Pb collisions in the AGS, SPS, and RHIC energy domains but larger than that observed for electroproduction from He. Taking into account all available data, we find the Lambda p source radius to increase almost linearly with the number of participants to the power of one-third.
|
|
|
HADES Collaboration(Agakishiev, G. et al), Diaz, J., & Gil, A. (2011). pp and pi pi intensity interferometry in collisions of Ar+KCl at 1.76A GeV. Eur. Phys. J. A, 47(5), 63–8pp.
Abstract: Results on pp, pi(+) pi(+), and pi-pi-intensity interferometry are reported for collisions of Ar+KCl at 1.76A GeV beam energy, studied with the High Acceptance Di-Electron Spectrometer (HADES) at SIS18/GSI. The experimental correlation functions as a function of the relative momentum are compared to model calculations allowing the determination of the space-time extent of the corresponding emission sources. The pp source radii are found significantly larger than the pp emission radius. The present radii do well complement the beam-energy dependences of Gaussian source radii of the collision system of size A + A similar or equal to 40 + 40. The pp source radius at fixed beam energy is found to increase linearly with the cube root of the number of participants. From this trend, a lower limit of the pp correlation radius is deduced.
|
|