Barenboim, G., & Park, W. I. (2015). Spiral inflation. Phys. Lett. B, 741, 252–255.
Abstract: We propose a novel scenario of primordial inflation in which the inflaton goes through a spiral motion starting from around the top of a symmetry breaking potential. We show that, even though inflation takes place for a field value much smaller than Planck scale, it is possible to obtain relatively large tensor-to-scalar ratio (r similar to 0.1) without fine tuning. The inflationary observables perfectly match Planck data.
|
Barenboim, G., & Park, W. I. (2015). Spiral inflation with Coleman-Weinberg potential. Phys. Rev. D, 91(6), 063511–5pp.
Abstract: We apply the idea of spiral inflation to the Coleman-Weinberg potential and show that inflation matching our observations well is allowed for a symmetry-breaking scale ranging from an intermediate scale to a grand unified theory (GUT) scale even if the quartic coupling lambda is of O(0.1). The tensor-to-scalar ratio can be of O(0.01) in the case of GUT-scale symmetry breaking.
|
Barrientos, D., Bellato, M., Bazzacco, D., Bortolato, D., Cocconi, P., Gadea, A., et al. (2015). Performance of the Fully Digital FPGA-Based Front-End Electronics for the GALILEO Array. IEEE Trans. Nucl. Sci., 62(6), 3134–3139.
Abstract: In this work we present the architecture and results of a fully digital Front End Electronics (FEE) read out system developed for the GALILEO array. The FEE system, developed in collaboration with the Advanced Gamma Tracking Array (AGATA) collaboration, is composed of three main blocks: preamplifiers, digitizers and preprocessing electronics. The slow control system contains a custom Linux driver, a dynamic library and a server implementing network services. This work presents the first results of the digital FEE system coupled with a GALILEO germanium detector, which has demonstrated the capability to achieve an energy resolution of 1.53% at an energy of 1.33 MeV, similar to the one obtained with a conventional analog system. While keeping a good performance in terms of energy resolution, digital electronics will allow to instrument the full GALILEO array with a versatile system with high integration and low power consumption and costs.
|
Barrio, J., Etxebeste, A., Lacasta, C., Muñoz, E., Oliver, J. F., Solaz, C., et al. (2015). Performance of VATA64HDR16 ASIC for medical physics applications based on continuous crystals and SiPMs. J. Instrum., 10, P12001–12pp.
Abstract: Detectors based on Silicon Photomultipliers (SiPMs) coupled to continuous crystals are being tested in medical physics applications due to their potential high resolution and sensitivity. To cope with the high granularity required for a very good spatial resolution, SiPM matrices with a large amount of elements are needed. To be able to read the information coming from each individual channel, dedicated ASICs are employed. The VATA64HDR16 ASIC is a 64-channel, charge-sensitive amplifier that converts the collected charge into a proportional current or voltage signal. A complete assessment of the suitability of that ASIC for medical physics applications based on continuous crystals and SiPMs has been carried out. The input charge range is linear from 20 pC up to 55 pC. The energy resolution obtained at 511 keV is 10% FWHM with a LaBr3 crystal and 16% FWHM with a LYSO crystal. A coincidence timing resolution of 24 ns FWHM is obtained with two LYSO crystals.
Keywords: Solid state detectors; Photon detectors for UV, visible and IR photons (solid-state) (PIN diodes, APDs, Si-PMTs, G-APDs, CCDs, EBCCDs, EMCCDs etc); Front-end electronics for detector readout; Gamma detectors (scintillators, CZT, HPG, HgI etc)
|
NA48/2 Collaboration(Batley, J. R. et al), & Fiorini, L. (2015). Search for the dark photon in pi(0) decays. Phys. Lett. B, 746, 178–185.
Abstract: A sample of 1.69 x 10(7) fully reconstructed pi(0) -> gamma e(+)e(-) decay candidates collected by the NA48/2 experiment at CERN in 2003-2004 is analyzed to search for the dark photon (A') production in the pi(0) -> gamma A' decay followed by the prompt A' -> e(+)e(-) decay. No signal is observed, and an exclusion region in the plane of the dark photon mass m(A') and mixing parameter epsilon(2) is established. The obtained upper limits on epsilon(2) are more stringent than the previous limits in the mass range 9 MeV/c(2) < m(A') < 70 MeV/c(2). The NA48/2 sensitivity to the dark photon production in the K-+/- -> pi(+/-)A' decay is also evaluated.
|