AGATA Collaboration, Doncel, M., Quintana, B., Gadea, A., Recchia, F., & Farnea, E. (2011). Background rejection capabilities of a Compton imaging telescope setup with a DSSD Ge planar detector and AGATA. Nucl. Instrum. Methods Phys. Res. A, 648, S131–S134.
Abstract: In this work, we show the first Monte Carlo results about the performance of the Ge array which we propose for the DESPEC experiment at FAIR, when the background algorithm developed for AGATA is applied. The main objective of our study is to characterize the capabilities of the gamma-spectroscopy system, made up of AGATA detectors in a semi-spherical distribution covering a 1 pi solid angle and a set of planar Ge detectors in a daisy configuration, to discriminate between gamma sources placed at different locations.
|
AGATA Collaboration, Domingo-Pardo, C., Bazzacco, D., Doornenbal, P., Farnea, E., Gadea, A., et al. (2012). Conceptual design and performance study for the first implementation of AGATA at the in-flight RIB facility of GSI. Nucl. Instrum. Methods Phys. Res. A, 694, 297–312.
Abstract: The main objective of the Advanced GAmma Tracking Array (AGATA) is the investigation of the structure of exotic nuclei at the new generation of RIB facilities. As part of the preparatory phase for FAIR-NUSTAR, AGATA is going to be installed at the FRS fragmentation facility of the GSI centre for an experimental campaign to be performed in 2012 and 2013. Owing to its gamma-ray tracking capabilities and the envisaged enhancement in resolving power, a series of in-flight gamma-ray spectroscopy experiments are being planned. The present work describes the conceptual design of this first implementation of AGATA at GSI-FRS, and provides information about the expected performance figures. According to the characteristics of each particular experiment, it is foreseen that the target-array distance is adjusted in order to achieve the optimum compromise between detection efficiency and energy resolution, or to cover an specific angular range of the emitted electromagnetic radiation. Thus, a comprehensive Monte Carlo study of the detection sensitivity in terms of photopeak efficiency, resolution and peak-to-total ratio, as a function of the target-array distance is presented. Several configurations have been investigated, and MC-calculations indicate that a remarkable enhancement in resolving power can be achieved when double-cluster AGATA detectors are developed and implemented. Several experimental effects are also investigated. This concerns the impact of passive materials between the target and the array, the angular distribution of the detection efficiency and the influence of target thickness effects and transition lifetimes in the attainable detection sensitivity. A short overview on half-life measurements via lineshape effects utilizing AGATA is also presented. (C) 2012 Elsevier B.V. All rights reserved.
|
AGATA Collaboration(Crespi, F. C. L. et al), & Gadea, A. (2014). Isospin Character of Low-Lying Pygmy Dipole States in Pb-208 via Inelastic Scattering of O-17 Ions. Phys. Rev. Lett., 113(1), 012501–5pp.
Abstract: The properties of pygmy dipole states in Pb-208 were investigated using the Pb-208(O-17, O-17'gamma) reaction at 340 MeV and measuring the gamma decay with high resolution with the AGATA demonstrator array. Cross sections and angular distributions of the emitted gamma rays and of the scattered particles were measured. The results are compared with (gamma, gamma') and (p, p') data. The data analysis with the distorted wave Born approximation approach gives a good description of the elastic scattering and of the inelastic excitation of the 2(+) and 3(-) states. For the dipole transitions a form factor obtained by folding a microscopically calculated transition density was used for the first time. This has allowed us to extract the isoscalar component of the 1(-) excited states from 4 to 8 MeV.
|
AGATA Collaboration(Crespi, F. C. L. et al), & Gadea, A. (2015). 1(-) and 2(+) discrete states in Zr-90 populated via the (O-17, O-17 'gamma) reaction. Phys. Rev. C, 91(2), 024323–9pp.
Abstract: 2(+) and 1(-) states in Zr-90 were populated via the (O-17, O-17 'gamma) reaction at 340 MeV. The gamma decay was measured with high resolution using the AGATA (advanced gamma tracking array demonstrator array). Differential cross sections were obtained at few different angles for the scattered particle. The results of the elastic scattering and inelastic excitation of 2(+), 3(,)(-) and 1(-) states are compared with distorted-wave Born approximation (DWBA) calculations, using both the standard collective form factor and a form factor obtained by folding microscopically calculated transition densities. This allowed to extract the isoscalar component of the 1(-) state at 6.424 MeV. The comparison of the present (17O, 17O 'gamma) data with existing (gamma,gamma') and (p, p') data in the corresponding region of the gamma continuum (6-11 MeV), characterized by a large E1 component, shows completely different behaviors of the cross section as a function of the nuclear excitation energy. The comparison of the data with DWBA calculations suggests a decrease of the isoscalar strength in the cross section with increasing excitation energy.
|
AGATA Collaboration(Crespi, F. C. L. et al), & Gadea, A. (2013). Response of AGATA segmented HPGe detectors to gamma rays up to 15.1 MeV. Nucl. Instrum. Methods Phys. Res. A, 705, 47–54.
Abstract: The response of AGATA segmented HPGe detectors to gamma rays in the energy range 2-15 MeV was measured. The 15.1 MeV gamma rays were produced using the reaction d(B-11,n gamma)C-12 at E-beam=19.1 MeV, while gamma rays between 2 and 9 MeV were produced using an Am-Be-Fe radioactive source. The energy resolution and linearity were studied and the energy-to-pulse-height conversion resulted to be linear within 0.05%.Experimental interaction multiplicity distributions are discussed and compared with the results of Geant4 simulations. It is shown that the application of gamma-ray tracking allows a suppression of background radiation caused by n-capture in Ge nuclei. Finally the Doppler correction for the 15.1 MeV gamma line, performed using the position information extracted with Pulse-shape analysis is discussed.
|