|
ATF Collaboration(Bambade, P. e al), Alabau Pons, M., & Faus-Golfe, A. (2010). Present status and first results of the final focus beam line at the KEK Accelerator Test Facility. Phys. Rev. Spec. Top.-Accel. Beams, 13(4), 042801–10pp.
Abstract: ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U. S. scientists. The present status and first results are described.
|
|
|
Ballester, F., Granero, D., Perez-Calatayud, J., Venselaar, J. L. M., & Rivard, M. J. (2010). Study of encapsulated Tm-170 sources for their potential use in brachytherapy. Med. Phys., 37(4), 1629–1637.
Abstract: Methods: The authors have assumed a theoretical Tm-170 cylindrical source encapsulated with stainless steel and typical dimensions taken from the currently available HDR Ir-192 brachytherapy sources. The dose-rate distribution was calculated for this source using the GEANT4 Monte Carlo (MC) code considering both photon and electron Tm-170 spectra. The AAPM TG-43 U1 brachytherapy dosimetry parameters were derived. To study general properties of Tm-170 encapsulated sources, spherical sources encapsulated with stainless steel and platinum were also studied. Moreover, the influence of small variations in the active core and capsule dimensions on the dosimetric characteristics was assessed. Treatment times required for a Tm-170 source were compared to those for Ir-192 and Yb-169 for the same contained activity. Results: Due to the energetic beta spectrum and the large electron yield, the bremsstrahlung contribution to the dose was of the same order of magnitude as from the emitted gammas and characteristic x rays. Moreover, the electron spectrum contribution to the dose was significant up to 4 mm from the source center compared to the photon contribution. The dose-rate constant Lambda of the cylindrical source was 1.23 cGy h(-1) U-1. The behavior of the radial dose function showed promise for applications in brachytherapy. Due to the electron spectrum, the anisotropy was large for r < 6 mm. Variations in manufacturing tolerances did not significantly influence the final dosimetry data when expressed in cGy h(-1) U-1. For typical capsule dimensions, maximum reference dose rates of about 0.2, 10, and 2 Gy min(-1) would then be obtained for Tm-170, Ir-192, and Yb-169, respectively, resulting in treatment times greater than those for HDR Ir-192 brachytherapy. Conclusions: The dosimetric characteristics of source designs exploiting the low photon energy of Tm-170 were studied for potential application in HDR-brachytherapy. Dose-rate distributions were obtained for cylindrical and simplified spherical Tm-170 source designs (stainless steel and platinum capsule materials) using MC calculations. Despite the high activity of Tm-170, calculated treatment times were much longer than for Ir-192.
|
|
|
Balbinot, R., Carusotto, I., Fabbri, A., & Recati, A. (2010). Testing Hawking Particle Creation By Black Holes Through Correlation Measurements. Int. J. Mod. Phys. D, 19(14), 2371–2377.
Abstract: Hawking's prediction of thermal radiation by black holes has been shown by Unruh to be expected also in condensed matter systems. We show here that in a black hole-like configuration realized in a BEC this particle-creation does indeed take place and can be unambiguously identified via a characteristic pattern in the density-density correlations. This opens the concrete possibility of the experimental verification of this effect.
|
|
|
Pierre Auger Collaboration(Abraham, J. et al), & Pastor, S. (2010). Measurement of the energy spectrum of cosmic rays above 10(18) eV using the Pierre Auger Observatory. Phys. Lett. B, 685(4-5), 239–246.
Abstract: We report a measurement of the flux of cosmic rays with unprecedented precision and Statistics using the Pierre Auger Observatory Based on fluorescence observations in coincidence with at least one Surface detector we derive a spectrum for energies above 10(18) eV We also update the previously published energy spectrum obtained with the surface detector array The two spectra are combined addressing the systematic uncertainties and, in particular. the influence of the energy resolution on the spectral shape The spectrum can be described by a broken power law E-gamma with index gamma = 3 3 below the ankle which is measured at log(10)(E-ankle/eV) = 18 6 Above the ankle the spectrum is described by a power law with index 2 6 followed by a flux suppression, above about log(10)(E/eV) = 19 5, detected with high statistical significance.
|
|
|
BABAR Collaboration(Aubert, B. et al), Azzolini, V., Lopez-March, N., Martinez-Vidal, F., Milanes, D. A., & Oyanguren, A. (2010). Observation of the decay (B)over-bar(0) -> Lambda(+)(c)(p)over-bar pi(0). Phys. Rev. D, 82(3), 031102–8pp.
Abstract: In a sample of 467 x 10(6) B (B) over bar pairs collected with the BABAR detector at the PEP- II collider at SLAC we have observed the decay (B) over bar (0) -> Lambda(+)(c)(p) over bar pi(0) and measured the branching fraction to be (1.94 +/- 0.17 +/- 0.14 +/- 0.50 x 10(-4), where the uncertainties are statistical, systematic, and the uncertainty on the Lambda(+)(c) -> pK(-)pi(+) branching fraction, respectively. We determine an upper limit of 1.5 x 10(-6) at 90% C.L. for the product branching fraction B((B) over bar (0) -> Sigma(+)(c) (2455)(p) over bar) x B(Lambda(+)(c) -> pK(-) pi(+)). Furthermore, we observe an enhancement at the threshold of the invariant mass of the baryon- antibaryon pair.
|
|