|
Records |
Links |
|
Author |
Ramirez-Uribe, S.; Renteria-Olivo, A.E.; Rodrigo, G.; Sborlini, G.F.R.; Vale Silva, L. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title |
Quantum algorithm for Feynman loop integrals |
Type |
Journal Article |
|
Year |
2022 |
Publication |
Journal of High Energy Physics |
Abbreviated Journal |
J. High Energy Phys. |
|
|
Volume |
05 |
Issue |
5 |
Pages |
100 - 32pp |
|
|
Keywords |
Duality in Gauge Field Theories; Perturbative QCD; Scattering Amplitudes |
|
|
Abstract |
We present a novel benchmark application of a quantum algorithm to Feynman loop integrals. The two on-shell states of a Feynman propagator are identified with the two states of a qubit and a quantum algorithm is used to unfold the causal singular configurations of multiloop Feynman diagrams. To identify such configurations, we exploit Grover's algorithm for querying multiple solutions over unstructured datasets, which presents a quadratic speed-up over classical algorithms when the number of solutions is much smaller than the number of possible configurations. A suitable modification is introduced to deal with topologies in which the number of causal states to be identified is nearly half of the total number of states. The output of the quantum algorithm in IBM Quantum and QUTE Testbed simulators is used to bootstrap the causal representation in the loop-tree duality of representative multiloop topologies. The algorithm may also find application and interest in graph theory to solve problems involving directed acyclic graphs. |
|
|
Address ![sorted by Address field, descending order (down)](img/sort_desc.gif) |
[Ramirez-Uribe, Selomit; Renteria-Olivo, Andres E.; Rodrigo, German; Sborlini, German F. R.; Vale Silva, Luiz] Univ Valencia, Inst Fis Corpuscular, CSIC, Parc Cient, E-46980 Valencia, Spain, Email: norma.selomit.ramirez@ific.uv.es; |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1029-8479 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000796990400007 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
5230 |
|
Permanent link to this record |
|
|
|
|
Author |
Ralet, D. et al; Gadea, A.; Perez, R.M. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Evidence of octupole-phonons at high spin in Pb-207<bold> </bold> |
Type |
Journal Article |
|
Year |
2019 |
Publication |
Physics Letters B |
Abbreviated Journal |
Phys. Lett. B |
|
|
Volume |
797 |
Issue |
|
Pages |
134797 - 6pp |
|
|
Keywords |
AGATA spectrometer; gamma-Ray tracking; VAMOS plus plus spectrometer; Plunger device; Nuclear deformation; Octupole phonon |
|
|
Abstract |
A lifetime measurement of the 19/2(-) state in Pb-207 has been performed using the Recoil Distance Doppler-Shift (RDDS) method. The nuclei of interest were produced in multi-nucleon transfer reactions induced by a Pb-208 beam impinging on a Mo-100 enriched target. The beam-like nuclei were detected<bold> </bold>and identified in terms of their atomic mass number in the VAMOS++ spectrometer while the prompt gamma rays were detected by the AGATA tracking array. The measured large reduced transition probability B(E3, 19/2(-) -> 13/2(+)) = 40(8) W.u. is the first indication of the octupole phonon at high spin in Pb-207. An analysis in terms of a particle-octupole-vibration coupling model indicates that the measured B(E3) value in Pb-207 is compatible with the contributions from single-phonon and single particle E3 as well as E3 strength arising from the double-octupole-phonon 6(+) state, all adding coherently. A crucial aspect of the coupling model, namely the strong mixing between single-hole and the phonon-hole states, is confirmed in a realistic shell-model calculation. |
|
|
Address ![sorted by Address field, descending order (down)](img/sort_desc.gif) |
[Ralet, D.; Georgiev, G.; Ljungvall, J.; Dupont, E.; Konstantinopoulos, T.; Korichi, A.; Lozeva, R.] Univ Paris Saclay, Univ Paris Sud, CSNSM, CNRS IN2P3, F-91405 Orsay, France, Email: clement@ganil.fr |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Elsevier |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0370-2693 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000488071200015 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
4163 |
|
Permanent link to this record |
|
|
|
|
Author |
AGATA Collaboration (Ralet, D. et al); Gadea, A.; Perez-Vidal, R.M. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Toward lifetime and g factor measurements of short-lived states in the vicinity of Pb-208 |
Type |
Journal Article |
|
Year |
2017 |
Publication |
Physica Scripta |
Abbreviated Journal |
Phys. Scr. |
|
|
Volume |
92 |
Issue |
5 |
Pages |
054004 - 4pp |
|
|
Keywords |
multi-nucleon transfer reaction; lifetime measurement; AGATA; VAMOS plus |
|
|
Abstract |
The multi-nucleon transfer reaction mechanism was used to produce and study nuclei in the vicinity of 208Pb. This mass region is a test case for the nuclear shell model. The mass identification of the fragments was performed with the large acceptance magnetic spectrometer VAMOS++ coupled to the AGATA gamma-tracking array. This experiment aimed to determine both lifetimes and gyromagnetic ratios of excited states with the Cologne plunger device. The analysis indicates promising results with the possibility to determine several new lifetimes in this region. |
|
|
Address ![sorted by Address field, descending order (down)](img/sort_desc.gif) |
[Ralet, D.; Georgiev, G.; Konstantinopoulos, T.; Korichi, A.; Ljungvall, J.] Univ Paris Saclay, Univ Paris Sud, CNRS IN2P3, CSNSM, F-91405 Orsay, France, Email: damian.ralet@csnsm.in2p3.fr |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Iop Publishing Ltd |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0031-8949 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000399888300001 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
3092 |
|
Permanent link to this record |
|
|
|
|
Author |
Racker, J.; Pena, M.; Rius, N. |
![goto web page (via DOI) doi](img/doi.gif)
|
|
Title |
Leptogenesis with small violation of B – L |
Type |
Journal Article |
|
Year |
2012 |
Publication |
Journal of Cosmology and Astroparticle Physics |
Abbreviated Journal |
J. Cosmol. Astropart. Phys. |
|
|
Volume |
07 |
Issue |
7 |
Pages |
030 - 18pp |
|
|
Keywords |
leptogenesis; neutrino theory |
|
|
Abstract |
We analyze leptogenesis in the context of seesaw models with almost conserved lepton number, focusing on the L-conserving contribution to the flavoured CP asymmetries. We find that, contrary to previous claims, successful leptogenesis is feasible for masses of the lightest heavy neutrino as low as M-1 similar to 10(6) GeV, without resorting to the resonant enhancement of the CP asymmetry for strongly degenerate heavy neutrinos. This lower limit renders thermal leptogenesis compatible with the gravitino bound in supersymmetric scenarios. |
|
|
Address ![sorted by Address field, descending order (down)](img/sort_desc.gif) |
[Racker, J.; Pena, Manuel; Rius, Nuria] Univ Valencia, CSIC, Dept Fis Teor, Valencia 46071, Spain, Email: racker@ific.uv.es; |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Iop Publishing Ltd |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1475-7516 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000307079600025 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
no |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
1166 |
|
Permanent link to this record |
|
|
|
|
Author |
Quintero-Quintero, A.; Patiño-Camargo, G.; Soriano, A.; Palma, J.D.; Vilar-Palop, J.; Pujades, M.C.; Llorca-Domaica, N.; Ballester, F.; Vijande, J.; Candela-Juan, C. |
![find record details (via OpenURL) openurl](img/xref.gif)
|
|
Title |
Calibration of a thermoluminescent dosimeter worn over lead aprons in fluoroscopy guided procedures |
Type |
Journal Article |
|
Year |
2018 |
Publication |
Journal of Radiological Protection |
Abbreviated Journal |
J. Radiol. Prot. |
|
|
Volume |
38 |
Issue |
2 |
Pages |
549-563 |
|
|
Keywords |
backscatter correction factor; TLD; lead apron; fluoroscopy; eye lens dose |
|
|
Abstract |
Fluoroscopy guided interventional procedures provide remarkable benefits to patients. However, medical staff working near the scattered radiation field may be exposed to high cumulative equivalent doses, thus requiring shielding devices such as lead aprons and thyroid collars. In this situation, it remains an acceptable practice to derive equivalent doses to the eye lenses or other unprotected soft tissues with a dosimeter placed above these protective devices. Nevertheless, the radiation backscattered by the lead shield differs from that generated during dosimeter calibration with a water phantom. In this study, a passive personal thermoluminescent dosimeter (TLD) was modelled by means of the Monte Carlo (MC) code Penelope. The results obtained were validated against measurements performed in reference conditions in a secondary standard dosimetry laboratory. Next, the MC model was used to evaluate the backscatter correction factor needed for the case where the dosimeter is worn over a lead shield to estimate the personal equivalent dose H-p(0.07) to unprotected soft tissues. For this purpose, the TLD was irradiated over a water slab phantom with a photon beam representative of the result of a fluoroscopy beam scattered by a patient. Incident beam angles of 0 degrees and 60 degrees, and lead thicknesses between the TLD and phantom of 0.25 and 0.5 mm Pb were considered. A backscatter correction factor of 1.23 (independent of lead thickness) was calculated comparing the results with those faced in reference conditions (i.e., without lead shield and with an angular incidence of 0 degrees). The corrected dose algorithm was validated in laboratory conditions with dosi-meters irradiated over a thyroid collar and angular incidences of 0 degrees, 40 degrees and 60 degrees, as well as with dosimeters worn by interventional radiologists and cardiologists. The corrected dose algorithm provides a better approach to estimate the equivalent dose to unprotected soft tissues such as eye lenses. Dosimeters that are not shielded from backscatter radiation might underestimate personal equivalent doses when worn over a lead apron and, therefore, should be specifically characterized for this purpose. |
|
|
Address ![sorted by Address field, descending order (down)](img/sort_desc.gif) |
[Quintero-Quintero, A.; Patino-Camargo, G.] Univ Valencia, Dept Atom Mol & Nucl Phys, E-46100 Burjassot, Valencia, Spain, Email: ccanjuan@gmail.com |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Iop Publishing Ltd |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0952-4746 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000428913900001 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
3552 |
|
Permanent link to this record |