|
Batail, L., Davesne, D., Peru, S., Becker, P., Pastore, A., & Navarro, J. (2023). A three-ranged Gogny interaction in touch with pion exchange: promising results to improve infinite matter properties. Eur. Phys. J. A, 59(7), 173–11pp.
Abstract: We suggest a new Gogny-type finite-range effective interaction including a third Gaussian in the central term. Based on simple arguments valid for an arbitrary radial form factor, the three ranges are obtained in connection with physical grounds, relating them to one-boson exchange interactions. Moreover, some parameters of the longest range are fixed through the G-matrix elements of the One Pion Exchange Potential. On top of giving a fairly good description of atomic nuclei properties comparable with other existing parametrisations, the resulting interaction leads to a remarkable improvement of some infinite matter properties that are relevant for astrophysical calculations.
|
|
|
Batra, A., Bharadwaj, P., Mandal, S., Srivastava, R., & Valle, J. W. F. (2023). Phenomenology of the simplest linear seesaw mechanism. J. High Energy Phys., 07(7), 221–48pp.
Abstract: The linear seesaw mechanism provides a simple way to generate neutrino masses. In addition to Standard Model particles, it includes quasi-Dirac leptons as neutrino mass mediators, and a leptophilic scalar doublet seeding small neutrino masses. Here we review its associated physics, including restrictions from theory and phenomenology. The model yields potentially detectable μ-> e gamma rates as well as distinctive signatures in the production and decay of heavy neutrinos ( N-i) and the charged Higgs boson (H-+/-) arising from the second scalar doublet. We have found that production processes such as e(+) e(-) -> NN, e- gamma -> NH- and e(+) e(-) -> H (+) H- followed by the decay chain H-+/--> l(+/-) (i) N, N -> l`(+/-) (j) W (-/+) leads to striking lepton number violation signatures at high energies which may probe the Majorana nature of neutrinos.
|
|
|
Bayar, M., Martinez Torres, A., Khemchandani, K. P., Molina, R., & Oset, E. (2023). Exotic states with triple charm. Eur. Phys. J. C, 83(1), 46–9pp.
Abstract: In this work we investigate the possibility of the formation of states from the dynamics involved in the D* D* D* system by considering that two D*'s generate a JP = 1+ bound state, with isospin 0, which has been predicted in an earlier theoretical work. We solve the Faddeev equations for this system within the fixed center approximation and find the existence of J(P) = 0(-), 1(-) and 2(-) states with charm 3, isospin 1/2, masses similar to 6000 MeV, which are manifestly exotic hadrons, i.e., with a multiquark inner structure.
|
|
|
Bayar, M., Feijoo, A., & Oset, E. (2023). X(3960) seen in Ds plus Ds- as the X(3930) state seen in D plus D. Phys. Rev. D, 107(3), 034007–5pp.
Abstract: We perform a calculation of the interaction of the D over bar D, Ds over bar Ds coupled channels and find two bound states, one coupling to DD over bar and another one at higher energies coupling mostly to D+s D-s . We identify this latter state with the X0(3930) seen in the D+D- mass distribution in the B+ -D+D-K+ decay, and also show that it produces an enhancement of the D+s D-s mass distribution close to threshold which is compatible with the recent LHCb observation in the B+ -D+s D-s K+ decay which has been identified as a new state, X0(3960).
|
|
|
Beaulieu, L., Ballester, F., Granero, D., Tedgren, A. C., Haworth, A., Lowenstein, J. R., et al. (2023). AAPM WGDCAB Report 372: A joint AAPM, ESTRO, ABG, and ABS report on commissioning of model-based dose calculation algorithms in brachytherapy. Med. Phys., 50(8), e946–e960.
Abstract: The introduction of model-based dose calculation algorithms (MBDCAs) in brachytherapy provides an opportunity for a more accurate dose calculation and opens the possibility for novel, innovative treatment modalities. The joint AAPM, ESTRO, and ABG Task Group 186 (TG-186) report provided guidance to early adopters. However, the commissioning aspect of these algorithms was described only in general terms with no quantitative goals. This report, from the Working Group on Model-Based Dose Calculation Algorithms in Brachytherapy, introduced a field-tested approach to MBDCA commissioning. It is based on a set of well-characterized test cases for which reference Monte Carlo (MC) and vendor-specific MBDCA dose distributions are available in a Digital Imaging and Communications in Medicine-Radiotherapy (DICOM-RT) format to the clinical users. The key elements of the TG-186 commissioning workflow are now described in detail, and quantitative goals are provided. This approach leverages the well-known Brachytherapy Source Registry jointly managed by the AAPM and the Imaging and Radiation Oncology Core (IROC) Houston Quality Assurance Center (with associated links at ESTRO) to provide open access to test cases as well as step-by-step user guides. While the current report is limited to the two most widely commercially available MBDCAs and only for Ir-192-based afterloading brachytherapy at this time, this report establishes a general framework that can easily be extended to other brachytherapy MBDCAs and brachytherapy sources. The AAPM, ESTRO, ABG, and ABS recommend that clinical medical physicists implement the workflow presented in this report to validate both the basic and the advanced dose calculation features of their commercial MBDCAs. Recommendations are also given to vendors to integrate advanced analysis tools into their brachytherapy treatment planning system to facilitate extensive dose comparisons. The use of the test cases for research and educational purposes is further encouraged.
|
|